900 research outputs found

    VEGF with AMD3100 Endogenously Mobilizes Mesenchymal Stem Cells and Improves Fracture Healing

    Get PDF
    A significant number of fractures develop non‐union. Mesenchymal stem cell (MSC) therapy may be beneficial, however, this requires cell acquisition, culture and delivery. Endogenous mobilization of stem cells offers a non‐invasive alternative. The hypothesis was administration of VEGF and the CXCR4 antagonist AMD3100 would increase the circulating pool of available MSCs and improve fracture healing. Ex‐breeder female wistar rats received VEGF followed by AMD3100, or sham PBS. Blood prepared for culture and colonies were counted. P3 cells were analyzed by flow cytometry, bi‐differentiation. The effect of mobilization on fracture healing was evaluated with 1.5 mm femoral osteotomy stabilized with an external fixator in 12–14 week old female Wistars. The mobilized group had significantly greater number of cfus/ml compared to controls, p = 0.029. The isolated cells expressed 1.8% CD34, 35% CD45, 61% CD29, 78% CD90, and differentiated into osteoblasts but not into adipocytes. The fracture gap in animals treated with VEGF and AMD3100 showed increased bone volume; 5.22 ± 1.7 µm3 and trabecular thickness 0.05 ± 0.01 µm compared with control animals (4.3 ± 3.1 µm3, 0.04 ± 0.01 µm, respectively). Radiographic scores quantifying fracture healing (RUST) showed that the animals in the mobilization group had a higher healing score compared to controls (9.6 vs. 7.7). Histologically, mobilization resulted in significantly lower group variability in bone formation (p = 0.032) and greater amounts of bone and less fibrous tissue than the control group. Clinical significance: This pre‐clinical study demonstrates a beneficial effect of endogenous MSC mobilization on fracture healing, which may have translation potential to prevent or treat clinical fractures at risk of delayed or non‐union fractures

    Increasing Extension Volunteer Knowledge and Preparedness with Youth Protection Training Across Program Areas

    Get PDF
    The University of Georgia (UGA) has a training requirement for adults working with youth. To meet this requirement for Georgia 4-H and Extension Master Gardener volunteers, a standardized online training module was created and delivered across program areas. Volunteers were surveyed to evaluate training effectiveness and experience. Understanding of UGA youth protocols and service preparedness increased after training for both volunteer groups, though preparedness may be affected by life stage, engagement in youth service roles, and/or comfort with virtual training. The module was considered accessible and convenient by respondents, thus providing a successful approach for offering trainings across program areas

    Reconstruction methods — P‾ANDA focussing-light guide disc DIRC

    Get PDF
    The Focussing-Lightguide Disc DIRC will provide crucial Particle Identification (PID) information for the P‾ANDA experiment at FAIR, GSI. This detector presents a challenging environment for reconstruction due to the complexity of the expected hit patterns and the operating conditions of the P‾ANDA experiment. A discussion of possible methods to reconstruct PID from this detector is given here. Reconstruction software is currently under development

    The bar PANDA focussing-lightguide disc DIRC

    Get PDF
    bar PANDA will be a fixed target experiment internal to the HESR antiproton storage ring at the future FAIR complex. The ANDA detector requires excellent particle-identification capabilities in order to achieve its scientific potential. Cherenkov counters employing the DIRC principle were chosen as PID detectors for the Target Spectrometer. The proposed Focussing-Lightguide Disc DIRC will cover the forward part of the Target Spectrometer acceptance in the angular range between 5° and 22°. Its design includes a novel approach to mitigate dispersion effects in the solid radiator of a DIRC counter using optical elements. The dispersion correction will enable the Focussing-Lightguide Disc DIRC to provide pion-kaon identification for momenta well above 3.5 GeV/c

    Photoaffinity labeling of corticotropin receptors.

    Full text link

    A multimodal pathway including the basal ganglia in the feline brain

    Get PDF
    The purpose of this paper is to give an overview of our present knowledge about the feline tecto-thalamo-basal ganglia cortical sensory pathway. We reviewed morphological and electrophysiological studies of the cortical areas, located in ventral bank of the anterior ectosylvian sulcus as well as the region of the insular cortex, the suprageniculate nucleus of the thalamus, caudate nucleus, and the substantia nigra. Microelectrode studies revealed common receptive field properties in all these structures. The receptive fields were extremely large and multisensory, with pronounced sensitivity to motion of visual stimuli. They often demonstrated directional and velocity selectivity. Preference for small visual stimuli was also a frequent finding. However, orientation sensitivity was absent. It became obvious that the structures of the investigated sensory loop exhibit a unique kind of information processing, not found anywhere else in the feline visual system

    Technical Design Report for the PANDA Micro Vertex Detector

    Get PDF
    This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined

    Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets

    Get PDF
    This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process

    Physics Performance Report for PANDA Strong Interaction Studies with Antiprotons

    Get PDF
    To study fundamental questions of hadron and nuclear physics in interactions of antiprotons with nucleons and nuclei, the universal PANDA detector will be build. Gluonic excitations, the physics of strange and charm quarks and nucleon structure studies will be performed with unprecedented accuracy thereby allowing high-precision tests of the strong interaction. The proposed PANDA detector is a state-of-the-art internal target detector at the HESR at FAIR allowing the detection and identifcation of neutral and charged particles generated within the relevant angular and energy range. This report presents a summary of the physics accessible at PANDA and what performance can be expected
    corecore