300 research outputs found

    Miniature electrometer preamplifier effectively compensates for input capacitance

    Get PDF
    Negative capacitance preamplifier using a dual MOS /Metal Oxide Silicon/ transistor in conjunction with bipolar transistors is used with intracellular microelectrodes in recording bioelectric potentials. Applications would include use as a pickup plate video amplifier in storage tube tests and for pH and ionization chamber measurements

    Optical addressing of an individual erbium ion in silicon

    Full text link
    The detection of electron spins associated with single defects in solids is a critical operation for a range of quantum information and measurement applications currently under development. To date, it has only been accomplished for two centres in crystalline solids: phosphorus in silicon using electrical readout based on a single electron transistor (SET) and nitrogen-vacancy centres in diamond using optical readout. A spin readout fidelity of about 90% has been demonstrated with both electrical readout and optical readout, however, the thermal limitations of the electrical readout and the poor photon collection efficiency of the optical readout hinder achieving the high fidelity required for quantum information applications. Here we demonstrate a hybrid approach using optical excitation to change the charge state of the defect centre in a silicon-based SET, conditional on its spin state, and then detecting this change electrically. The optical frequency addressing in high spectral resolution conquers the thermal broadening limitation of the previous electrical readout and charge sensing avoids the difficulties of efficient photon collection. This is done with erbium in silicon and has the potential to enable new architectures for quantum information processing devices and to dramatically increase the range of defect centres that can be exploited. Further, the efficient electrical detection of the optical excitation of single sites in silicon is a major step in developing an interconnect between silicon and optical based quantum computing technologies.Comment: Corrected the third affiliation. Corrected one cross-reference of "Fig. 3b" to "Fig. 3c". Corrected the caption of Fig. 3a by changing (+-)1 to

    Single rare-earth ions as atomic-scale probes in ultra-scaled transistors

    Full text link
    Continued dimensional scaling of semiconductor devices has driven information technology into vastly diverse applications. As the size of devices approaches fundamental limits, metrology techniques with nanometre resolution and three-dimensional (3D) capabilities are desired for device optimisation. For example, the performance of an ultra-scaled transistor can be strongly influenced by the local electric field and strain. Here we study the spectral response of single erbium ions to applied electric field and strain in a silicon ultra-scaled transistor. Stark shifts induced by both the overall electric field and the local charge environment are observed. Further, changes in strain smaller than 3×1063\times 10^{-6} are detected, which is around two orders of magnitude more sensitive than the standard techniques used in the semiconductor industry. These results open new possibilities for non-destructive 3D mapping of the local strain and electric field in the channel of ultra-scaled transistors, using the single erbium ions as ultra-sensitive atomic probes.Comment: 10+5 pages, 4+3 figure

    Sub-megahertz homogeneous linewidth for Er in Si via in situ single photon detection

    Full text link
    We studied the optical properties of a resonantly excited trivalent Er ensemble in Si accessed via in situ single photon detection. A novel approach which avoids nanofabrication on the sample is introduced, resulting in a highly efficient detection of 70 excitation frequencies, of which 63 resonances have not been observed in literature. The center frequencies and optical lifetimes of all resonances have been extracted, showing that 5% of the resonances are within 1 GHz of our electrically detected resonances and that the optical lifetimes range from 0.5 ms up to 1.5 ms. We observed inhomogeneous broadening of less than 400 MHz and an upper bound on the homogeneous linewidth of 1.4 MHz and 0.75 MHz for two separate resonances, which is a reduction of more than an order of magnitude observed to date. These narrow optical transition properties show that Er in Si is an excellent candidate for future quantum information and communication applications.Comment: 12 pages, 13 figure

    Millisecond electron spin coherence time for erbium ions in silicon

    Full text link
    Spins in silicon that are accessible via a telecom-compatible optical transition are a versatile platform for quantum information processing that can leverage the well-established silicon nanofabrication industry. Key to these applications are long coherence times on the optical and spin transitions to provide a robust system for interfacing photonic and spin qubits. Here, we report telecom-compatible Er3+ sites with long optical and electron spin coherence times, measured within a nuclear spin-free silicon crystal (<0.01% 29Si) using optical detection. We investigate two sites and find 0.1 GHz optical inhomogeneous linewidths and homogeneous linewidths below 70 kHz for both sites. We measure the electron spin coherence time of both sites using optically detected magnetic resonance and observe Hahn echo decay constants of 0.8 ms and 1.2 ms at around 11 mT. These optical and spin properties of Er3+:Si are an important milestone towards using optically accessible spins in silicon for a broad range of quantum information processing applications.Comment: 14 pages, 6 figure

    Survey of Canadian Animal-Based Researchers' Views on the Three Rs: Replacement, Reduction and Refinement

    Get PDF
    The ‘Three Rs’ tenet (replacement, reduction, refinement) is a widely accepted cornerstone of Canadian and international policies on animal-based science. The Canadian Council on Animal Care (CCAC) initiated this web-based survey to obtain greater understanding of ‘principal investigators’ and ‘other researchers’ (i.e. graduate students, post-doctoral researchers etc.) views on the Three Rs, and to identify obstacles and opportunities for continued implementation of the Three Rs in Canada. Responses from 414 participants indicate that researchers currently do not view the goal of replacement as achievable. Researchers prefer to use enough animals to ensure quality data is obtained rather than using the minimum and potentially waste those animals if a problem occurs during the study. Many feel that they already reduce animal numbers as much as possible and have concerns that further reduction may compromise research. Most participants were ambivalent about re-use, but expressed concern that the practice could compromise experimental outcomes. In considering refinement, many researchers feel there are situations where animals should not receive pain relieving drugs because it may compromise scientific outcomes, although there was strong support for the Three Rs strategy of conducting animal welfare-related pilot studies, which were viewed as useful for both animal welfare and experimental design. Participants were not opposed to being offered “assistance” to implement the Three Rs, so long as the input is provided in a collegial manner, and from individuals who are perceived as experts. It may be useful for animal use policymakers to consider what steps are needed to make replacement a more feasible goal. In addition, initiatives that offer researchers greater practical and logistical support with Three Rs implementation may be useful. Encouragement and financial support for Three Rs initiatives may result in valuable contributions to Three Rs knowledge and improve welfare for animals used in science

    Novel Indirect Calorimetry Technology to Analyze Metabolism in Individual Neonatal Rodent Pups

    Get PDF
    BACKGROUND: The ability to characterize the development of metabolic function in neonatal rodents has been limited due to technological constraints. Low respiratory volumes and flows at rest pose unique problems, making it difficult to reliably measure O(2) consumption, CO(2) production, respiratory quotient (RQ), and energy expenditure (EE). Our aim was to develop and validate a commercial-grade indirect calorimetry system capable of characterizing the metabolic phenotype of individual neonatal rodents. METHODOLOGY/PRINCIPAL FINDINGS: To address this research need, we developed a novel, highly sensitive open-circuit indirect calorimetry system capable of analyzing respiratory gas exchange in a single neonatal rodent pup. Additionally, we derived an equation from known metabolic relationships to estimate inlet flow rates, improving the efficiency of data collection. To validate the neonatal rodent indirect calorimetry system and evaluate the applicability of the derived equation for predicting appropriate flow rates, we conducted a series of experiments evaluating the impact of sex, litter size, time of day (during the light phase), and ambient temperature on neonatal rat metabolic parameters. Data revealed that the only metabolic parameter influenced by litter size is a neonatal rat's RQ, with rat pups reared in a small litter (5 pups) having lower RQ's than rat pups reared in either medium (8 pups) or large (11 pups) litters. Furthermore, data showed that ambient temperature affected all metabolic parameters measured, with colder temperatures being associated with higher CO(2) production, higher O(2) consumption, and higher energy expenditure. CONCLUSION/SIGNIFICANCE: The results of this study demonstrate that the modified Panlab Oxylet system reliably assesses early postnatal metabolism in individual neonatal rodents. This system will be of paramount importance to further our understanding of processes associated with the developmental origins of adult metabolic disease
    corecore