1,692 research outputs found
Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the Inner Tracking System of HERA-B
The results of five years of development of the inner tracking system of the
HERA-B experiment and first experience from the data taking period of the year
2000 are reported. The system contains 184 chambers, covering a sensitive area
of about 20 * 20 cm2 each. The detector is based on microstrip gas counters
(MSGCs) with diamond like coated (DLC) glass wafers and gas electron
multipliers (GEMs). The main problems in the development phase were gas
discharges in intense hadron beams and aging in a high radiation dose
environment. The observation of gas discharges which damage the electrode
structure of the MSGC led to the addition of the GEM as a first amplification
step. Spurious sparking at the GEM cannot be avoided completely. It does not
affect the GEM itself but can produce secondary damage of the MSGC if the
electric field between the GEM and the MSGC is above a threshold depending on
operation conditions. We observed that aging does not only depend on the dose
but also on the spot size of the irradiated area. Ar-DME mixtures had to be
abandoned whereas a mixture of 70% Ar and 30% CO2 showed no serious aging
effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements
indicate that the DLC of the MSGC is deteriorated by the gas amplification
process. As a consequence, long term gain variations are expected. The Inner
Tracker has successfully participated in the data taking at HERA-B during
summer 2000.Comment: 29 pages, 22 figure
Investigation of the performance of an optimised MicroCAT, a GEM and their combination by simulations and current measurements
A MicroCAT (Micro Compteur A Trous) structure which is used for avalanche
charge multiplication in gas filled radiation detectors has been optimised with
respect to maximum electron transparency and minimum ion feedback. We report on
the charge transfer behaviour and the achievable gas gain of this device. A
three-dimensional electron and ion transfer simulation is compared to results
derived from electric current measurements. Similarly, we present studies of
the charge transfer behaviour of a GEM (Gas Electron Multiplier) by current
measurements and simulations. Finally, we investigate the combination of the
MicroCAT and the GEM by measurements with respect to the performance at
different voltage settings, gas mixtures and gas pressures.Comment: 26 pages, 32 figure
Confronting classical and Bayesian confidence limits to examples
Classical confidence limits are compared to Bayesian error bounds by studying
relevant examples. The performance of the two methods is investigated relative
to the properties coherence, precision, bias, universality, simplicity. A
proposal to define error limits in various cases is derived from the
comparison. It is based on the likelihood function only and follows in most
cases the general practice in high energy physics. Classical methods are
discarded because they violate the likelihood principle, they can produce
physically inconsistent results, suffer from a lack of precision and
generality. Also the extreme Bayesian approach with arbitrary choice of the
prior probability density or priors deduced from scaling laws is rejected.Comment: 16 pages, 12 figure
Nonparametric Regression using the Concept of Minimum Energy
It has recently been shown that an unbinned distance-based statistic, the
energy, can be used to construct an extremely powerful nonparametric
multivariate two sample goodness-of-fit test. An extension to this method that
makes it possible to perform nonparametric regression using multiple
multivariate data sets is presented in this paper. The technique, which is
based on the concept of minimizing the energy of the system, permits
determination of parameters of interest without the need for parametric
expressions of the parent distributions of the data sets. The application and
performance of this new method is discussed in the context of some simple
example analyses.Comment: 10 pages, 4 figure
- …