77 research outputs found

    The Role of Millimeter-Waves in the Distance Measurement Accuracy of an FMCW Radar Sensor

    Get PDF
    High-accuracy, short-range distance measurement is required in a variety of industrial applications e.g., positioning of robots in a fully automated production process, level measurement of liquids in small containers. An FMCW radar sensor is suitable for this purpose, since many of these applications involve harsh environments. Due to the progress in the field of semiconductor technology, FMCW radar sensors operating in different millimeter-wave frequency bands are available today. An important question in this context, which has not been investigated so far is how does a millimeter-wave frequency band influence the sensor accuracy, when thousands of distance measurements are performed with a sensor. This topic has been dealt with for the first time in this paper. The method used for analyzing the FMCW radar signal combines a frequency- and phase-estimation algorithm. The frequency-estimation algorithm based on the fast Fourier transform and the chirp-z transform provides a coarse estimate of the target distance. Subsequently, the phase-estimation algorithm based on a cross-correlation function provides a fine estimate of the target distance. The novel aspects of this paper are as follows. First, the estimation theory concept of Cramér-Rao lower bound (CRLB) has been used to compare the accuracy of two millimeter-wave FMCW radars operating at 60 GHz and 122 GHz. In this comparison, the measurement parameters (e.g., bandwidth, signal-to-noise ratio) as well as the signal-processing algorithm used for both the radars are the same, thus ensuring an unbiased comparison of the FMCW radars, solely based on the choice of millimeter-wave frequency band. Second, the improvement in distance measurement accuracy obtained after each step of the combined frequency- and phase-estimation algorithm has been experimentally demonstrated for both the radars. A total of 5100 short-range distance measurements are made using the 60 GHz and 122 GHz FMCW radar. The measurement results are analyzed at various stages of the frequency- and phase-estimation algorithm and the measurement error is calculated using a nanometer-precision linear motor. At every stage, the mean error values measured with the 60 GHz and 122 GHz FMCW radars are compared. The final accuracy achieved using both radars is of the order of a few micrometers. The measured standard deviation values of the 60 GHz and 122 GHz FMCW radar have been compared against the CRLB. As predicted by the CRLB, this paper experimentally validates for the first time that the 122 GHz FMCW radar provides a higher repeatability of micrometer-accuracy distance measurements than the 60 GHz FMCW radar. View Full-Tex

    First Directional Measurement of sub-MeV Solar Neutrinos with Borexino

    Get PDF
    We report the measurement of sub-MeV solar neutrinos through the use of their associated Cherenkov radiation, performed with the Borexino detector at the Laboratori Nazionali del Gran Sasso. The measurement is achieved using a novel technique that correlates individual photon hits of events to the known position of the Sun. In an energy window between 0.54 to 0.74 MeV, selected using the dominant scintillation light, we have measured 10 887ĂŸ2386 Ă°statÞ ïżœ 947Ă°systÞ (68% confidence interval) −2103 solar neutrinos out of 19904 total events. This corresponds to a 7Be neutrino interaction rate of 51.6ĂŸ13.9 counts=Ă°day · 100 tonÞ, which is in agreement with the standard solar model predictions and the −12.5 previous spectroscopic results of Borexino. The no-neutrino hypothesis can be excluded with > 5σ confidence level. For the first time, we have demonstrated the possibility of utilizing the directional Cherenkov information for sub-MeV solar neutrinos, in a large-scale, high light yield liquid scintillator detector. This measurement provides an experimental proof of principle for future hybrid event reconstruction using both Cherenkov and scintillation signatures simultaneously

    Experimental Detection of the CNO Cycle

    Get PDF
    Borexino recently reported the first experimental evidence for a CNO neutrino. Since this process accounts for only about 1% of the Sun’s total energy production, the associated neutrino flux is remarkably low compared to that of the pp chain, the dominant hydrogen-burning process. This experimental evidence for the existence of CNO neutrinos was obtained using a highly radio-pure Borexino liquid scintillator. Improvements in the thermal stabilization of the detector over the last five years have allowed us to exploit a method of constraining the rate of 210Bi background. Since the CNO cycle is dominant in massive stars, this result is the first experimental evidence of a major stellar hydrogen-to-helium conversion mechanism in the Universe

    Solar and geoneutrinos

    Get PDF
    Thanks to the progress of neutrino physics, today we are able of exploiting neutrinos as a tool to study astrophysical objects. The latter in turn serve as unique sources of elusive neutrinos, which fundamental properties are still to be understood. This contribution attempts to summarize the latest results obtained by measuring neutrinos emitted from the Sun and geoneutrinos produced in radioactive decays inside the Earth, with a particular focus on a recent discovery of the CNO-cycle solar neutrinos by Borexino. Comprehensive measurement of the pp-chain solar neutrinos and the first directional detection of sub-MeV solar neutrinos by Borexino, the updated 8B solar neutrino results of Super-Kamiokande, as well as the latest Borexino and KamLAND geoneutrino measurements are also discussed

    Identification of the cosmogenic 11C background in large volumes of liquid scintillators with Borexino

    Get PDF
    Cosmogenic radio-nuclei are an important source of background for low-energy neutrino experiments. In Borexino, cosmogenic 11C decays outnumber solar pep and CNO neutrino events by about ten to one. In order to extract the flux of these two neutrino species, a highly efficient identification of this background is mandatory. We present here the details of the most consolidated strategy, used throughout Borexino solar neutrino measurements. It hinges upon finding the space-time correlations between 11C decays, the preceding parent muons and the accompanying neutrons. This article describes the working principles and evaluates the performance of this Three-Fold Coincidence (TFC) technique in its two current implementations: a hard-cut and a likelihood-based approach. Both show stable performances throughout Borexino Phases II (2012–2016) and III (2016–2020) data sets, with a 11C tagging efficiency of ∌90 % and ∌ 63–66 % of the exposure surviving the tagging. We present also a novel technique that targets specifically 11C produced in high-multiplicity during major spallation events. Such 11C appear as a burst of events, whose space-time correlation can be exploited. Burst identification can be combined with the TFC to obtain about the same tagging efficiency of ∌90% but with a higher fraction of the exposure surviving, in the range of ∌ 66–68 %

    Influence of inflow cannula length in axial-flow pumps on neurologic adverse event rate: results from a multi-center analysis

    Full text link
    BACKGROUND: The application of axial-flow pumps in patients with end-stage heart failure reveals a significantly reduced infectious complication rate as compared with rates observed with pulsatile devices. The remaining adverse event rate relates mainly to thromboembolic complications with neurologic consequences. We investigated the dependence of the neurologic adverse event rate on the length of the inflow cannula. METHODS: A total of 216 consecutive patients with an axial-flow pump (INCOR; Berlin Heart GmbH, Berlin, Germany) were included in a retrospective multi-center analysis. In 138 patients, a short inflow cannula (24-mm tip length into the left ventricle), and in 78 patients a long inflow cannula (tip length 34 mm) was applied. RESULTS: Patients with a long inflow cannula (LC) demonstrated a better survival rate than those with a short inflow cannula (SC) at the end of the observation period (LC, 63.4%; SC, 52.9%; p = 0.05). The thromboembolic adverse event rate was also significantly lower. Only 3 of the 78 patients (3.8%) with an LC had a thromboembolic adverse event (thromboembolic events per patient-year = 0.11) as compared with 32 (23.2%) of SC patients (thromboembolic events per patient-year = 0.50, p < 0.001). CONCLUSIONS: Patients with a long inflow cannula had a better survival rate and a lower incidence of cerebrovascular adverse events than patients with a short inflow cannula
    • 

    corecore