28 research outputs found

    The ability of contemporary cardiologists to judge the ischemic impact of a coronary lesion visually

    Get PDF
    Background: Landmark trials showed that invasive pressure measurement (Fractional Flow Reserve, FFR) was a better guide to coronary stenting than visual assessment. However, present-day interventionists have benefited from extensive research and personal experience of mapping anatomy to hemodynamics. Aims: To determine if visual assessment of the angiogram performs as well as invasive measurement of coronary physiology. Methods: 25 interventional cardiologists independently visually assessed the single vessel coronary disease of 200 randomized participants in The Objective Randomized Blinded Investigation with optimal medical Therapy of Angioplasty in stable angina trial (ORBITA). They gave a visual prediction of the FFR and Instantaneous Wave-free Ratio (iFR), denoted vFFR and viFR respectively. Each judged each lesion on 2 occasions, so that every lesion had 50 vFFR, and 50 viFR assessments. The group consensus visual estimates (vFFR-group and viFR-group) and individual cardiologists' visual estimates (vFFR-individual and viFR-individual) were tested alongside invasively measured FFR and iFR for their ability to predict the placebo-controlled reduction in stress echo ischemia with stenting. Results: Placebo-controlled ischemia improvement with stenting was predicted by vFFR-group (p < 0.0001) and viFR-group (p < 0.0001), vFFR-individual (p < 0.0001) and viFR-individual (p < 0.0001). There were no significant differences between the predictive performance of the group visual estimates and their invasive counterparts: p = 0.53 for vFFR vs FFR and p = 0.56 for viFR vs iFR. Conclusion: Visual assessment of the angiogram by contemporary experts, provides significant additional information on the amount of ischaemia which can be relieved by placebo-controlled stenting in single vessel coronary artery disease

    Coronary Artery Hematoma Treated with Fenestration Using a Novel NSE Alpha® Scoring Balloon

    No full text
    The optimal management of coronary intramural hematoma has not been defined. We described a case in which coronary occlusion developed due to an intramural hematoma after percutaneous coronary intervention for mid left circumflex artery (LCX). Intravascular ultrasound (IVUS) demonstrated the progression of the intramural hematoma and a totally compressed true lumen. Our approach was based on fenestration with a scoring balloon (NSE Alpha, Goodman, Japan), which allowed the deployment of an additional stent to be avoided. In conclusion, this management can be effectively and safely performed

    The bending technique of a scoring balloon Aperta NSE leading to successful crossing into stents

    No full text
    Abstract A new scoring balloon Aperta NSE has 3 longitudinal nylon elements mounted on the non‐compliant balloon surface. Although a high‐pressure balloon is usually used as a post‐dilation balloon in an implanted stent, it is difficult to pass into the stents because a balloon gets caught in stents in some cases. Aperta NSE has some grooves at elements; therefore, this balloon is bendable and shaped in an arc. The bent scoring balloon could eliminate interference between the balloon and the stents or lesions. Moreover, the point where the tip of the balloon contacts could change. As a result, it helps to improve crossability of this balloon. The bending technique of a scoring balloon Aperta NSE could lead to successful crossing into stents or complex lesions

    Intraprocedural left ventricular free wall rupture diagnosed by left ventriculogram in a patient with infero-posterior myocardial infarction and severe aortic stenosis

    Get PDF
    Background: Left ventricular wall rupture remains a major lethal complication of acute myocardial infarction and hypertension is a well-known predisposing factor of cardiac rupture after myocardial infarction. Case presentation: An 87-year-old man was admitted to our hospital, diagnosed as acute myocardial infarction (AMI). The echocardiogram showed 0.67-cm2 aortic valve, consistent with severe aortic stenosis (AS). A coronary angiography showed a chronic occlusion of the proximal left circumflex artery and a 99 % stenosis and thrombus in the mid right coronary artery. During percutaneous angioplasty of the latter, transient hypotension and bradycardia developed at the time of balloon inflation, and low doses of noradrenaline and etilefrine were intravenously administered as needed. The patient suddenly lost consciousness and developed electro-mechanical dissociation. Cardio-pulmonary resuscitation followed by insertion of an intra-aortic balloon pump (IABP) and percutaneous cardiopulmonary support were initiated. The echocardiogram revealed moderate pericardial effusion, though the site of free wall rupture was not distinctly visible. A left ventriculogram clearly showed an infero-posterior apical wall rupture. Surgical treatment was withheld because of the interim development of brain death. Conclusions: In this patient, who presented with severe AS, the administration of catecholamine to stabilize the blood pressure probably increased the intraventricular pressures considerably despite apparently normal measurements of the central aortic pressure. IABP, temporary pacemaker, or both are recommended instead of intravenous catecholamines for patients with AMI complicated with significant AS to stabilize hemodynamic function during angioplasty
    corecore