423 research outputs found

    Definition and classification for adverse events following spinal and peripheral joint manipulation and mobilization: A scoping review

    Full text link
    INTRODUCTION Spinal and peripheral joint manipulation and mobilization are interventions used by many healthcare providers to manage musculoskeletal conditions. Although there are many reports of adverse events (or undesirable outcomes) following such interventions, there is no common definition for an adverse event or clarity on any severity classification. This impedes advances of patient safety initiatives and practice. This scoping review mapped the evidence of adverse event definitions and classification systems following spinal and peripheral joint manipulation and mobilization for musculoskeletal conditions in adults. METHODS An electronic search of the following databases was performed from inception to February 2021: MEDLINE, EMBASE, CINAHL, Scopus, AMED, ICL, PEDro, Cochrane Library, Open Grey and Open Theses and Dissertations. Studies including adults (18 to 65 years old) with a musculoskeletal condition receiving spinal or peripheral joint manipulation or mobilization and providing an adverse event definition and/or classification were included. All study designs of peer-reviewed publications were considered. Data from included studies were charted using a standardized data extraction form and synthesised using narrative analysis. RESULTS From 8248 identified studies, 98 were included in the final synthesis. A direct definition for an adverse event and/or classification system was provided in 69 studies, while 29 provided an indirect definition and/or classification system. The most common descriptors to define an adverse event were causality, symptom severity, onset and duration. Twenty-three studies that provided a classification system described only the end anchors (e.g., mild/minor and/or serious) of the classification while 26 described multiple categories (e.g., moderate, severe). CONCLUSION A vast array of terms, definition and classification systems were identified. There is no one common definition or classification for adverse events following spinal and peripheral joint manipulation and mobilization. Findings support the urgent need for consensus on the terms, definition and classification system for adverse events related to these interventions

    Chiropractic student diagnosis and management of headache disorders: A survey examining self-perceived preparedness and clinical proficiency.

    Full text link
    ObjectiveTo explore the self-perceived preparedness and clinical proficiency in headache diagnosis and management of Australian chiropractic students in senior years of study.MethodsAustralian chiropractic students in the 4th (n = 134) and 5th year (n = 122) of 2 chiropractic university programs were invited to participate in an online cross-sectional survey. Descriptive analyses were conducted for all variables. Post hoc analyses were performed using simple linear regression to evaluate the relationship between self-perceived preparedness and correctness of headache diagnosis and management scores.ResultsAustralian chiropractic students in senior years demonstrated moderate overall levels of self-perceived preparedness and proficiency in their ability to diagnose and manage headache disorders. Final-year students had a slightly higher self-perceived preparedness and proficiency in headache diagnosis and management compared to those students in the 4th year of study. There was no relationship between self-perceived preparedness and correctness of headache diagnosis and management for either 4th- or 5th-year chiropractic students.ConclusionOur findings suggest that there may be gaps in graduate chiropractic student confidence and proficiency in headache diagnosis and management. These findings call for further research to explore graduate chiropractic student preparedness and proficiency in the diagnosis and management of headache disorders

    Correlations Between Individuals' Characteristics and Spinal Stiffness in Individuals With and Without Back Pain: A Combined Analysis of Multiple Data Sets.

    Get PDF
    OBJECTIVE: The purpose of this study was to describe the correlations between individual characteristics and spinal stiffness as measured with different spinal stiffness measurement devices in individuals with and without back pain. METHODS: A secondary analysis of 3 adult data sets obtained using 3 different devices, in 2 spinal regions, from a total of 5 separate cross-sectional studies was conducted. Differences in spinal stiffness between men and women and in the strength of correlations among spinal stiffness and age and anthropometric characteristics were evaluated using either the t test for independent samples, Pearson's correlation coefficient, or Kendall's Ï„ rank correlation coefficient. RESULTS: As expected, results varied between data sets; however, few factors had consistent correlations. Specifically, spinal stiffness was significantly lower in women than men in all 3 data sets. Height was positively correlated with spinal stiffness across all data sets. Although weight was correlated with thoracic stiffness, its correlation with lumbar stiffness varied. In 2 data sets, body mass index was inversely associated with lumbar spinal stiffness, whereas results from the thoracic spine region revealed a positive correlation. The results for 1 data set suggest that physiological measurement evaluating body weight distribution may also affect spinal stiffness; however, the specific correlation remains unclear. CONCLUSION: Despite data set differences, significant correlations were observed, indicating that participants' characteristics appear to affect spinal stiffness measurement

    Clinicians' Ability to Detect a Palpable Difference in Spinal Stiffness Compared With a Mechanical Device.

    Get PDF
    OBJECTIVE: The purpose of this study was to quantify the threshold at which clinicians can detect a difference in spinal stiffness of the thoracic and lumbar spine via palpation and then determine if this detection threshold would affect a clinician's ability to identify changes in spinal stiffness as measured by an objective instrument. METHODS: In this study, the threshold at which a change in spinal stiffness was detected was quantified in 12 experienced clinicians (physical therapists and doctors of chiropractic) by changing the differential stiffness in 2 inflatable targets until the clinician could no longer identify which was stiffer. In the second part of the study, clinicians then were asked to palpate pre-identified pairs of vertebrae in an asymptomatic volunteer and to identify the stiffer of the pair (T7 and L3, T7 and L4, L3 and L4), and the biomechanical stiffness of each vertebral pair was quantified objectively by a validated instrument. RESULTS: The mean stiffness detection threshold for the clinicians was 8%. Objective measurement of the stiffness differential between vertebral pairs was 30% for T7* and L3, 20% for T7* and L4, and 10% for L3* and L4 (*denotes the stiffer of the pair). Ten of 12 clinicians correctly identified T7 as stiffer when compared with L3 and T7 as stiffer than L4. Alternatively, when the differential vertebral pair stiffness was similar to the stiffness detection threshold (~8%), clinicians were less successful in identifying the stiffer vertebra of the pair; 4 of 12 clinicians correctly identified L3 as being stiffer compared with L4. CONCLUSION: These results suggest that the physiological limits of human palpation may limit the ability of clinicians to identify small alterations in spine stiffness

    Antiulcerogenic and antioxidant activities of Baccharis trimera (Less) DC (Asteraceae)

    Get PDF
    A "carqueja", Baccharis trimera (Less) DC (Asteraceae), é uma espécie vegetal característica de regiões tropicais, muito utilizada na medicina popular como antiinflamatória, hipoglicemiante e em tratamento de problemas digestivos. A avaliação da atividade antiúlcera do extrato bruto liofilizado e do extrato liofilizado da "resina" (porção que durante a concentração dos extratos ficava depositada no fundo do recipiente com aspecto viscoso e pegajoso) foi realizada através de indução aguda por etanol acidificado. O extrato bruto liofilizado, na dose de 400 mg/ kg, reduziu a área de lesão em 90%, 200 mg/kg, 87%, 100 mg/kg, 66% e o fármaco controle (lansoprazol), 66%. O extrato liofilizado da "resina", administrado na dose de 400 mg/kg, reduziu a área de lesão em 82%, 200 mg/kg, 82%, 100 mg/kg, 53% e o fármaco controle (lansoprazol), 70%. A atividade antioxidante foi ensaiada com extrato bruto liofilizado, extrato liofilizado da "resina", pó da droga e frações clorofórmica, acetato de etila, etanol e etanol 50% através do método que reduz o radical 2,2'-difenil-1-picril-hidrazil (DPPH), permitindo após o equilíbrio da reação, calcular a quantidade de antioxidante gasta para reduzir 50% do DPPH, apresentando resultado evidente, comparado à vitamina E. Não foram verificados sinais de alteração aparente no ensaio de toxicidade na dose única de 5g/kg, em camundongos.Baccharis trimera (Less) DC (Asteraceae) is a medicinal Brazilian plant well-known by "carqueja". Natural from tropical regions, used as home-made medicine as anti-inflammatory, hypoglycemiant and for the treatment of digestive problems. The evaluation of the antiulcer activity of the extract and the "resin" (portion which during the extracts concentration was settled at the bottom of the recipient, showing a viscous and clammy aspect), was accomplished through the acute induction by acidified ethanol. The lyophilized extract, at a dose of 400 mg/kg, reduced the lesion area at 90%; 200 mg/kg, at 87%; 100 mg/kg, at 66%; and the control (lansoprazol) at 66%. The "resin" administered at the 400 mg/kg dose reduced the lesion area at 82%; 200 mg/kg, at 82%, 100 mg/kg, at 53% and the control (lansoprazol), at 70%. The antioxidant activity of the lyophilized extract, of the "resin" of the powdered drug, of the chloroform, ethyl acetate, ethanol and 50% ethanol fractions was tested following the method which reduces the 2,2-dipheny l-1 -picrylhydrazyl (DPPH) radical, permitting after the reaction balance, to calculate the amount of antioxidant spent to reduce 50% of the DPPH. The result was meaningful, when compared with the vitamin E result. The acute toxicity test performed in mice showed no apparent alteration

    Investigation of the factors influencing spinal manipulative therapy force transmission through the thorax: A cadaveric study

    Get PDF
    Abstract Spinal manipulative therapy (SMT) clinical effects are believed to be linked to its force–time profile characteristics. Previous studies have revealed that the force measured at the patient-table interface is most commonly greater than the one applied at the clinician-patient interface. The factors explaining this force amplification remains unclear. Objective To determine the difference between the force applied to a cadaveric specimen’s thoracic spine and the resulting force measured by a force-sensing table, as well as to evaluate the relationship between this difference and both the SMT force–time characteristics and the specimens’ characteristics. Methods Twenty-five SMTs with different force–time profiles were delivered by an apparatus at the T7 vertebra of nine human cadaveric specimens lying prone on a treatment table equipped with a force plate. The difference between the force applied by the apparatus and the resulting force measured by the force plate was calculated in absolute force (Fdiff) and as the percentage of the applied force (Fdiff%). Kinematics markers were inserted into T6 to T8 spinous and transverse processes to evaluate vertebral displacements during the SMT thrusts. Mixed-effects linear models were run to evaluate the variance in Fdiff and Fdiff% explained by SMT characteristics (peak force, thrust duration and force application rate), T6 to T8 relative and total displacements, and specimens’ characteristics (BMI, height, weight, kyphosis angle, thoracic thickness). Results Sixty percent of the trials showed lower force measured at the force plate than the one applied at T7. Fdiff¸ was significantly predicted (R2marginal = 0.54) by peak force, thrust duration, thoracic thickness and T6–T7 relative displacement in the z-axis (postero-anterior). Fdiff% was significantly predicted (R2marginal = 0.56) by force application rate, thoracic thickness and total T6 displacements. For both dependant variables, thoracic thickness showed the highest R2marginal out of all predictors. Conclusion Difference in force between the clinician-patient and the patient-table interfaces is influenced by SMT force–time characteristics and by thoracic thickness. How these differences in force are associated with vertebral displacements remains unclear. Although further studies are needed, clinicians should consider thorax thickness as a possible modulator of forces being transmitted through it during prone SMT procedures

    Devices used to measure force-time characteristics of spinal manipulations and mobilizations: A mixed-methods scoping review on metrologic properties and factors influencing use

    Get PDF
    Background: Spinal manipulations (SMT) and mobilizations (MOB) are interventions commonly performed by many health care providers to manage musculoskeletal conditions. The clinical effects of these interventions are believed to be, at least in part, associated with their force-time characteristics. Numerous devices have been developed to measure the force-time characteristics of these modalities. The use of a device may be facilitated or limited by different factors such as its metrologic properties.Objectives: This mixed-method scoping review aimed to characterize the metrologic properties of devices used to measure SMT/MOB force-time characteristics and to determine which factors may facilitate or limit the use of such devices within the context of research, education and clinical practice. Methods: This study followed the Joanna Briggs Institute's framework. The literature search strategy included four concepts: (1) devices, (2) measurement of SMT or MOB force-time characteristics on humans, (3) factors facilitating or limiting the use of devices, and (4) metrologic properties. Two reviewers independently reviewed titles, abstracts and full articles to determine inclusion. To be included, studies had to report on a device metrologic property (e.g., reliability, accuracy) and/or discuss factors that may facilitate or limit the use of the device within the context of research, education or clinical practice. Metrologic properties were extracted per device. Limiting and facilitating factors were extracted and themes were identified. Results: From the 8,998 studies initially retrieved, 46 studies were finally included. Ten devices measuring SMT/MOB force-time characteristics at the clinician-patient interface and six measuring them at patient-table interfaces were identified. Between zero and eight metrologic properties were reported per device: measurement error (defined as validity, accuracy, fidelity, or calibration), reliability/repeatability, coupling/crosstalk effect, linearity/correlation, sensitivity, variability, drift, and calibration. From the results, five themes related to the facilitating and limiting factors were developed: user-friendliness and versatility, metrologic/intrinsic properties, cost and durability, technique application, and feedback. Conclusion: Various devices are available to measure SMT/MOB force-time characteristics. Metrologic properties were reported for most devices, but terminology standardization is lacking. The usefulness of a device in a particular context should be determined considering the metrologic properties as well as other potential facilitating and limiting factors

    Association of Exposures to Seated Postures With Immediate Increases in Back Pain: A Systematic Review of Studies With Objectively Measured Sitting Time

    Get PDF
    have determined sitting time by self-report and/or LBP by recall following exposure. Given known problems with recall and the validity of estimated sitting time, we conducted a systematic review of studies using objectively measured sitting time to determine if sitting time is associated with immediate LBP in adults. Methods: Four databases (PubMed, EMBASE, SPORTDiscus and CINAHL) were searched from inception to September 1, 2018. Randomized controlled trials, cohort and cross-sectional studies, where objectively measured sitting time was temporally matched with a measure of LBP in adults, were included. Studies without a control session conducted on a separate day were excluded. Screening, full text review, data extraction and risk of bias assessment (QUIPS) of included papers were performed independently by two reviewers, with a third available to resolve disagreements. Results: In total, 609 articles were identified, 361 titles/abstracts were screened,75 full-text articles were assessed for eligibility and 10 met the inclusion criteria. All but one reported sitting time to be associated with immediate increase in LBP. Six of these reported clinically relevant pain levels (n=330). Half of the included studies were rated as having low risk of bias and the remaining as moderate risk of bias. Conclusion: Prolonged sitting increases immediate reporting of LBP in adults; however, no conclusion between sitting and clinical episodes of LBP can be made. Future prospective studies should match objectively measured sitting with temporally related pain measurements to determine whether prolonged sitting can trigger a clinical episode of LBP
    • …
    corecore