40 research outputs found

    Stochastic formalism for U(1) gauge fields in axion inflation

    Full text link
    We develop the stochastic formalism for U(1)\mathrm{U}(1) gauge fields that has the Chern-Simons coupling to a rolling pseudo-scalar field during inflation. The Langevin equations for the physical electromagnetic fields are derived and the analytic solutions are studied. Using numerical simulation we demonstrate that the electromagnetic fields averaged over the Hubble scale continuously change their direction and their amplitudes fluctuate around the analytically obtained expectation values. Though the isotropy is spontaneously broken by picking up a particular local Hubble patch, each Hubble patch is understood independent and the isotropy is conserved globally by averaging all the Hubble patches.Comment: 15pages, 4 figure

    Effective treatment of U(1) gauge field and charged particles in axion inflation

    Full text link
    The axionic inflaton with the Chern-Simons coupling may generate U(1) gauge fields and charged particles simultaneously. In order to incorporate the backreaction from the charged particles on the gauge fields, we develop a procedure to obtain an equilibrium solution for the gauge fields by treating the induced current as effective electric and magnetic conductivities. Introducing mean field approximation, and numerically solving self-consistency equations, we find that the gauge field amplitudes are drastically suppressed. Interestingly, as the production becomes more efficient, the charged particles gain a larger part of the transferred energy from the inflaton and eventually dominate it. Our formalism offers a basis to connect this class of inflationary models to a rich phenomenology such as baryogenesis and magnetogenesis.Comment: 28 pages, 7 figure

    視野左方偏倚が線分二等分試験に及ぼす影響 : Head Mounted Displayを用いた若年健常者に対する検討

    Get PDF
    Objective: The purpose of this study was to verify the effect on spatial perception in healthy young subjects of an unconscious leftward optical shift created by a head-mounted display (HMD) with an offset camera. Methods: We recruited 40 healthy right-handed adults who were divided into four groups according to the hand used in the tests and the visual direction displayed by the HMD (centered or 10° left). Each of the four groups (n = 10) undertook line bisection tasks across four combinations of variables: using a finger/stick or a mouse to point at a touch panel located 60 or 120 cm away from the subject. Results: According to the results, regardless of the hand used, when the index finger or a stick was used (reaching condition), the line bisection point was displaced significantly to the left of the center. Additionally, a major left-displacement trend was observed in the short-distance reaching task, which did not require the use of a stick. In contrast, the long-distance task required a stick to be used, and the left displacements were all smaller than those for the short-distance tasks that used the index finger. Conclusion: This finding may be explained by the subjects having sufficient experience coordinating hand and eye movements in the condition where they used their dominant hand and reached with their own arms without using a stick.東京都立大学学位論文甲第1160号 副論

    Optimal Intravascular Ultrasound-Guided Percutaneous Coronary Intervention in Patients With Multivessel Disease

    Get PDF
    BACKGROUND: Intravascular ultrasound (IVUS) was only rarely used in landmark trials comparing percutaneous coronary intervention (PCI) with coronary artery bypass grafting (CABG) in patients with multivessel disease. OBJECTIVES: The authors aimed to evaluate clinical outcomes after optimal IVUS-guided PCI in patients undergoing multivessel PCI. METHODS: The OPTIVUS (OPTimal IntraVascular UltraSound)-Complex PCI study multivessel cohort was a prospective multicenter single-arm study enrolling 1, 021 patients undergoing multivessel PCI, including left anterior descending coronary artery using IVUS, aiming to meet the prespecified criteria (OPTIVUS criteria: minimum stent area > distal reference lumen area [stent length ≥28mm], and minimum stent area >0.8 × average reference lumen area [stent length <28mm]) for optimal stent expansion. The primary endpoint was major adverse cardiac and cerebrovascular events (MACCE) (death/myocardial infarction/stroke/any coronary revascularization). The predefined performance goals were derived from the CREDO-Kyoto (Coronary REvascularization Demonstrating Outcome study in Kyoto) PCI/CABG registry cohort-2 fulfilling the inclusion criteria in this study. RESULTS: In this study, 40.1% of the patients met OPTIVUS criteria in all stented lesions. The cumulative 1-year incidence of the primary endpoint was 10.3% (95% CI: 8.4%-12.2%), which was significantly lower than the predefined PCI performance goal of 27.5% (P < 0.001), and which was numerically lower than the predefined CABG performance goal of 13.8%. The cumulative 1-year incidence of the primary endpoint was not significantly different regardless of meeting or not meeting OPTIVUS criteria. CONCLUSIONS: Contemporary PCI practice conducted in the OPTIVUS-Complex PCI study multivessel cohort was associated with a significantly lower MACCE rate than the predefined PCI performance goal, and with a numerically lower MACCE rate than the predefined CABG performance goal at 1 year

    Fabrication of Polarization Grating on <i>N</i>-Benzylideneaniline Polymer Liquid Crystal and Control of Diffraction Beam

    No full text
    Photoresponsive photoalignable liquid crystalline polymers composed of phenyl benzoate terminated with N-benzylideneaniline were evaluated. These polymers are capable of axis-selective photoreaction, photoinduced orientation, and surface relief grating formation. Polarization holography using an He-Cd laser beam at a wavelength of 325 nm demonstrated the formation of a surface relief grating with a molecularly oriented structure based on periodic light-induced reorientation and molecular motion. Electrical switching of diffracted light using an electric field response of twisted-nematic cell containing a low-molecular-weight liquid crystal in combination was also demonstrated

    Modulation of the mechanical properties of ventricular extracellular matrix hydrogels with a carbodiimide crosslinker and investigation of their cellular compatibility

    No full text
    Hydrogels made from the cardiac extracellular matrix (ECM) as two-dimensional (2D) or 3D cell-culture substrates have beneficial biochemical effects on the differentiation of stem cells into cardiomyocytes. The mechanical properties of the substrates that match those of the host tissues have been identified as critical biophysical cues for coaxing the tissue-specific differentiation of stem cells. The objectives of the present study are (1) to fabricate hydrogels comprising pure ventricular ECM (vECM), (2) to make the gels possess mechanical properties similar to those of the decellularized ventricular tissue, and (3) to evaluate the cellular compatibility of the hydrogels. In order to achieve these aims, (1) a simplified protocol was developed to produce vECM solution easily and rapidly, (2) N-(3-Dimethylaminopropyl)-N’-ethylcarbodiimide hydrochloride (EDAC) was chosen to crosslink the hydrogels made from the vECM solution to enhance their mechanical properties and stabilize the microstructure of the gels, (3) rat embryonic fibroblasts or cardiomyocytes were cultured on these gels to determine the cellular compatibility of the gels. In particular, the nonlinearity and viscoelasticity of the gels were characterized quantitatively using a newly proposed nonlinear Kelvin model. The results showed that EDAC treatment allowed modulation of the mechanical properties of the gels to the same level as those of decellularized ventricular tissue in terms of the equilibrium elasticity and relaxation coefficient. Cell culture confirmed the cellular compatibility of the gels. Furthermore, an empirical relationship between the equilibrium elastic modulus of the gels and the vECM and EDAC concentrations was derived, which is important to tailor the mechanical properties of the gels. Finally, the influence of the mechanical properties of the gels on the behavior of cultured fibroblasts and cardiomyocytes was discussed
    corecore