8,843 research outputs found

    Rotational spectrum of cis–cis HOONO

    Get PDF
    The pure rotational spectrum of cis-cis peroxynitrous acid, HOONO, has been observed. Over 220 transitions, sampling states up to J(')=67 and K-a(')=31, have been fitted with an rms uncertainty of 48.4 kHz. The experimentally determined rotational constants agree well with ab initio values for the cis-cis conformer, a five-membered ring formed by intramolecular hydrogen bonding. The small, positive inertial defect Delta=0.075667(60) amu A(2) and lack of any observable torsional splittings in the spectrum indicate that cis-cis HOONO exists in a well-defined planar structure at room temperature

    Rotational spectroscopy and dipole moment of cis-cis HOONO and DOONO

    Get PDF
    The rotational spectrum of cis-cis HOONO has been studied over a broad range of frequencies, 13–840 GHz, using pulsed beam Fourier-transform microwave spectroscopy and room-temperature flow cell submillimeter spectroscopy. The rotational spectrum of the deuterated isotopomer, cis-cis DOONO, has been studied over a subset of this range, 84–640 GHz. Improved spectroscopic constants have been determined for HOONO, and the DOONO spectrum is analyzed for the first time. Weak-field Stark effect measurements in the region of 84–110 GHz have been employed to determine the molecular dipole moments of cis-cis HOONO [µa=0.542(8) D,µb=0.918(15) D,µ=1.07(2) D] and DOONO [µa=0.517(9) D,µb=0.930(15) D,µ=1.06(2) D]. The quadrupole coupling tensor in the principal inertial axis system for the 14N nucleus has been determined to be chiaa=1.4907(25) MHz,chibb=–4.5990(59) MHz,chiab=3.17(147) MHz, and chicc=3.1082(59) MHz. Coordinates of the H atom in the center-of-mass frame have been determined with use of the Kraitchman equations, |aH|=0.516 Å and |bH|=1.171 Å. The inertial defects of HOONO and DOONO are consistent with a planar equilibrium structure with significant out-of-plane H atom torsional motion. Comparisons of the present results are made to ab initio calculations

    Clinical Validation of the Ansi C63.19 Draft Standard for Measuring Compatibility between Digital Wireless Phones and Hearing Aids

    Get PDF
    Acoustic interference can be generated in hearing aids by the pulsed transmission signal of a digital wireless phone. This interference, resembling a buzzing, clicking, or static sound, is annoying and can seriously degrade the intelligibility of the speech. The objective of the ANSI C63.19 Draft Standard is to provide a simple, reliable test procedure for measuring the immunity of hearing aids to this interference. To clinically validate the standard, hearing aids were custom manufactured for eighteen hearing-impaired participants. The participants rated the effects of the interference experienced when using five digital wireless phone technologies (CDMA at 800 and 1900 MHz, TDMA-50 Hz at 800 and 1900 MHz, and TDMA-217 Hz at 1900 MHz) at five transmission power levels (0, 6, 12, 18, and 24 dBm). More than two-thirds of the subjects responded as predicted by acoustic measurements of the interference. The remaining subjects experienced difficulties unrelated to wireless phone interference due to severe hearing loss or excessive feedback. These results support the use of acoustic measurements of immunity as the basis for the ANSI C63.19 standard.Yeshttps://us.sagepub.com/en-us/nam/manuscript-submission-guideline

    Cardiovascular Disease

    Get PDF
    <p>Abstract</p> <p>Health Issue</p> <p>Cardiovascular disease (CVD) is the leading cause of death in Canadian women and men. In general, women present with a wider range of symptoms, are more likely to delay seeking medial care and are less likely to be investigated and treated with evidence-based medications, angioplasty or coronary artery bypass graft than men.</p> <p>Key Findings</p> <p>In 1998, 78,964 Canadians died from CVD, almost half (39,197) were women. Acute myocardial infarction, which increases significantly after menopause, was the leading cause of death among women.</p> <p>Cardiovascular disease accounted for 21% of all hospital admissions for Canadian women over age 50 in 1999. Admissions to hospital for ischemic heart disease were more frequent for men, but the mean length of hospital stay was longer for women.</p> <p>Mean blood pressure increases with age in both men and women. After age 65, however, high blood pressure is more common among Canadian women. More than one-third of postmenopausal Canadian women have hypertension.</p> <p>Diabetes increases the mortality and morbidity associated with CVD in women more than it does in men. Depression also contributes to the incidence and recovery from CVD, particularly for women who experience twice the rate of depression as men.</p> <p>Data Gaps and Recommendations</p> <p>CVD needs to be recognized as a woman's health issue given Canadian mortality projections (particularly heart failure). Health professionals should be trained to screen, track, and address CVD risk factors among women, including hypertension, elevated lipid levels, smoking, physical inactivity, depression, diabetes and low socio-economic status.</p

    Constraints on Galaxy Bias, Matter Density, and Primordial Non--Gausianity from the PSCz Galaxy Redshift Survey

    Get PDF
    We compute the bispectrum for the \IRAS PSCz catalog and find that the galaxy distribution displays the characteristic signature of gravity. Assuming Gaussian initial conditions, we obtain galaxy biasing parameters 1/b1=1.20−0.19+0.181/b_1=1.20^{+0.18}_{-0.19} and b2/b12=−0.42±0.19b_2/b_1^2=-0.42\pm0.19, with no sign of scale-dependent bias for k≤0.3k\leq 0.3 h/Mpc. These results impose stringent constraints on non-Gaussian initial conditions. For dimensional scaling models with χN2\chi^2_N statistics, we find N>49, which implies a constraint on primordial skewness B3<0.35B_3<0.35.Comment: 4 pages, 3 embedded figures, uses revtex style file, minor changes to reflect published versio

    Inefficiency as the major driver of excess costs in lung resection

    Get PDF
    BackgroundRisk-adjusted outcomes of surgical care are important for quality and cost assessments. Although cardiac surgery is commonly studied, risk-adjusted analysis of excess costs of lung resection has not been pursued.MethodsWe used 2002 to 2005 National Inpatient Sample of the Healthcare Cost and Utilization Project data to evaluate adverse outcomes and costs in elective lung resections in hospitals with more than 20 cases during that period. Adverse outcomes were inpatient death or excessive risk-adjusted postoperative stay. Logistic models were defined to predict adverse outcomes. Linear models were designed to predict costs. Hospital-specific adverse outcome rates and costs were measured to define performance outliers. Cost-effective reference hospitals were used to define total excess costs.ResultsAmong 12,182 patients at 215 hospitals undergoing lung resection, there were 336 inpatient deaths (2.8%) and 880 live discharges with prolonged risk-adjusted postoperative stay (7.2%). Predictive models for mortality and risk-adjusted postoperative stay had C statistics of 0.773 and 0.643, respectively. There were 11 ineffective hospitals (5.1%) with excessive adverse outcomes (P < .005) and 34 inefficient hospitals (15.8%) meeting quality measures but with higher than predicted costs (P < .0005). Ineffective hospitals had costs 1020percaselowerthanpredicted.Inefficienthospitalshadcosts1020 per case lower than predicted. Inefficient hospitals had costs 9978 higher than predicted.ConclusionsInefficiency is the major factor in excess inpatient costs associated with lung resection in this model. Although refinements in databases, including total physician costs and postdischarge adverse event costs, will alter models, excess costs of lung resection appear to be driven by inefficiency, not adverse outcomes

    A Field-Test of Rhodamine B as a Biomarker in Raccoons

    Get PDF
    Rhodamine B is a dye that when ingested results in fluorescent bands in growing hair and whiskers of many mammals. Previous research at Wildlife Services’ (WS) National Wildlife Research Center (NWRC) found that rhodamine B is a successful biomarker in raccoon whiskers and that raccoons do not have a taste aversion to the dye when it comprises ≤ 3% of a bait. Our study assessed the ease of bait distribution, whisker collection, and evaluation of the biomarker for potential use in the Oral Rabies Vaccination (ORV) program administered by the WS National Rabies Management Program (NRMP). In collaboration with WS operations personnel from Ohio and Michigan, 750 fishmeal polymer baits each containing 150 mg of rhodamine B were hand distributed at NASA\u27s Plum Brook Station, Sandusky, Ohio in the summer of 2008. Four weeks after baits were distributed whiskers from 162 raccoons were collected. Wildlife Services biologists and technicians evaluated the whiskers for fluorescence using a handheld UV magnifying lamp. Biologists then sent the whiskers to the NWRC, Ft. Collins, Colorado for confirmation of fluorescence under a UV microscope. Results suggest a high level of agreement between the two methods of evaluation. Surveys completed by biologists confirmed that the ease of use, less invasive sampling techniques and promptness of results obtained through the use of rhodamine B are advantageous to the tetracycline biomarker presently used by the ORV program. All participants recommended further evaluation of rhodamine B for its inclusion in future efforts requiring biomarker evaluation
    • …
    corecore