64 research outputs found

    SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site

    Get PDF
    Purpose: SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and a conventional computerised tomography (CT). SPECT/CT allows accurate anatomical localisation of metabolic tracer activity. It allows the correlation of surgical factors such as tunnel position and orientation with mechanical alignment, clinical outcome and biological factors. The purpose of this study was to investigate whether the SPECT/CT tracer uptake (intensity and distribution) correlates with the stability and laxity of the knee joint and the position and orientation of the tibial and femoral tunnels in patients after anterior cruciate ligament (ACL) reconstruction. Methods: A consecutive series of knees (n = 66), with symptoms of pain and/or instability after ACL reconstruction were prospectively evaluated using clinical examination and 99mTc-HDP-SPECT/CT. Clinical laxity testing was performed using the Rolimeter (Ormed, Freiburg, Germany) including Lachman testing (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), anterior drawer test (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), pivot shift test (positive versus negative) and patient-based subjective instability (yes versus no). For analysis of SPECT/CT tracer uptake a previously validated SPECT/CT localisation scheme consisting of 17 tibial, nine femoral and four patellar regions on standardised axial, coronal, and sagittal slices was used. The tracer activity on SPECT/CT was localised and recorded using a 3D volumetric and quantitative analysis software. Mean, standard deviation, minimum and maximum of grading for each area of the localisation scheme were recorded. The position and orientation of the tibial and femoral tunnel was assessed using a previously published method on 3D-CT. Results: Correlation of instability, pivot shift as well as clinical laxity testing with 99mTc-HDP-SPECT/CT tracer uptake intensity and distribution showed no significant correlation. 99mTc-HDP-SPECT/CT tracer uptake correlated significantly with the position and orientation of the ACL graft. A more horizontal femoral graft position showed significantly increased tracer uptake within the superior and posterior femoral regions. A more posteriorly-placed femoral insertion site showed significantly more tracer uptake within the femoral and tibial tunnel regions. A more vertical or a less medial tibial tunnel orientation showed significant increased uptake within the tibial and femoral tunnel regions. A more anterior tibial tunnel position showed significantly more tracer uptake in the femoral and tibial tunnel regions as well as the entire tibiofemoral joint. Conclusions: SPECT/CT tracer uptake intensity and distribution showed a significant correlation with the femoral and tibial tunnel position and orientation in patients with symptomatic knees after ACL reconstruction. No correlation was found with stability or clinical laxity. SPECT/CT tracer uptake distribution has the potential to give us important information on joint homeostasis and remodelling after ACL reconstruction. It might help to predict ACL graft failure and improve our surgical ACL reconstruction technique in finding the optimal tunnel and graft position and orientatio

    The unhappy total knee arthroplasty (TKA) patient: higher WOMAC and lower KSS in depressed patients prior and after TKA

    Get PDF
    Purpose: Patient-based and psychological factors do influence outcome in patients undergoing total knee arthroplasty (TKA). The purpose was to investigate if preoperative psychological factors influence the subjective and objective outcomes 6weeks, 4months and 1year after TKA. Our hypothesis was that there is a significant influence of psychological factors on clinical outcome scores before and after TKA. Methods: A prospective, longitudinal, single-cohort study investigating the correlation of depression, control beliefs, anxiety and a variety of other psychological factors with outcomes of patients undergoing TKA was performed. A total of 104 consecutive patients were investigated preoperatively using the Beck'ss depression inventory, the State-Trait Anxiety Index, the questionnaire for assessment of control beliefs and the SCL-90R inventory. The Knee Society Clinical Rating System (KSS) and the WOMAC were used. Analysis of TKA position was performed on radiographs according to Ewald et al. Correlation of psychological variables with outcomes was performed (p<.05). Results: Self-efficacy did not influence clinical scores. More depressed patients showed higher pre- and postoperative WOMAC scores, but no difference in amelioration. KSS scores were not influenced. Patients with higher State and Trait Anxiety Indexes had higher WOMAC and lower KSS scores before and after the operation, but most significant correlations were <0.3. Several SCL-90 dimensions had significant correlations with pre- and postoperative clinical scores, but not with their amelioration. The SCL-90 subscore for somatization and the overall SCL-90 significantly correlated with the WOMAC, KSS before and after TKA. Conclusions: Depression, anxiety, a tendency to somatize and psychological distress were identified as significant predictors for poorer clinical outcomes before and/or after TKA. Standardized preoperative screening and subsequent treatment should become part of the preoperative work-up in orthopaedic practice. Level of evidence: Prognostic prospective, Level

    Optical fibers for endoscopic high-power Er:YAG laserosteotomy

    Full text link
    ignificance: The highest absorption peaks of the main components of bone are in the mid-infrared region, making Er:YAG and CO2 lasers the most efficient lasers for cutting bone. Yet, studies of deep bone ablation in minimally invasive settings are very limited, as finding suitable materials for coupling high-power laser light with low attenuation beyond 2  μm is not trivial. Aim: The first aim of this study was to compare the performance of different optical fibers in terms of transmitting Er:YAG laser light with a 2.94-μm wavelength at high pulse energy close to 1 J. The second aim was to achieve deep bone ablation using the best-performing fiber, as determined by our experiments. Approach: In our study, various optical fibers with low attenuation (λ  =  2.94  μm) were used to couple the Er:YAG laser. The fibers were made of germanium oxide, sapphire, zirconium fluoride, and hollow-core silica, respectively. We compared the fibers in terms of transmission efficiency, resistance to high Er:YAG laser energy, and bending flexibility. The best-performing fiber was used to achieve deep bone ablation in a minimally invasive setting. To do this, we adapted the optimal settings for free-space deep bone ablation with an Er:YAG laser found in a previous study. Results: Three of the fibers endured energy per pulse as high as 820 mJ at a repetition rate of 10 Hz. The best-performing fiber, made of germanium oxide, provided higher transmission efficiency and greater bending flexibility than the other fibers. With an output energy of 370 mJ per pulse at 10 Hz repetition rate, we reached a cutting depth of 6.82  ±  0.99  mm in sheep bone. Histology image analysis was performed on the bone tissue adjacent to the laser ablation crater; the images did not show any structural damage. Conclusions: The findings suggest that our prototype could be used in future generations of endoscopic devices for minimally invasive laserosteotomy

    Assessment of in vivo loading history of the patellofemoral joint: a study combining patellar position, tilt, alignment and bone SPECT/CT

    Get PDF
    Purpose: The current study investigates whether patella height and tilt or leg alignment influence the intensity values as well as the distribution pattern of single photon emission computerized tomography/computerized tomography (SPECT/CT) tracer uptake in the patellofemoral joint. Methods: 99mTc-HDP-SPECT/CT and radiographs of consecutive 84 knees were prospectively obtained. Lateral radiographs were analyzed in terms of patellar height, Insall-Salvati index and modified Insall-Salvati index. Skyline views were analyzed for Laurin's lateral patellofemoral angle. On long-leg radiographs, the mechanical leg alignment was classified as varus, valgus or neutral. SPECT/CT was analyzed for each anatomical region using a previously validated SPECT/CT localization and grading algorithm. Mean, standard deviation, minimum and maximum of grading for each area of the localization scheme were recorded. Nonparametric Spearman's correlations were used to correlate patellar height, lateral patellar angle and leg alignment with the tracer uptake intensity. Chi-square statistics were used for categorical data (p<0.05). Results: A patella baja correlated significantly with higher SPECT/CT tracer uptake in all patellar and lateral femoral regions (p<0.001). A higher lateral patellar tilt correlated significantly with higher tracer uptake in the superior lateral femoral parts and the tibial tubercle. In mechanically varus aligned knees, there was significantly higher SPECT/CT tracer uptake on the medial and in valgus knees on the lateral part of the patellofemoral joint (p<0.05). Conclusions: As the intensity and distribution of the SPECT/CT significantly correlated with patella baja and patellar tilt, SPECT/CT might be considered as imaging modality for evaluating patients with patellofemoral disorders and for follow-up of patients after patellofemoral realignment procedures. Level of evidence: Diagnostic study, Level II

    Micro- and nanosystems for biology and medicine

    Get PDF
    The development of new tools and instruments for biomedical applications based on nano- (NEMS) or microelectromechanical systems technology (MEMS) are bridging the gap between the macro- and the nano-world. The well mastered microtechnique allows controlling many parameters of these instruments, which is essential for conducting reproducible and repeatable experiments in the life sciences. Examples are multifunctional scanning probe sensors for cell biology, an arthroscopic scanning force microscope for minimally invasive medical interventions and a nanopore sensor for single molecule experiments in biochemistry. This paper reviews some of the activities conducted in a fruitful interdisciplinary collaboration between physicists, engineers, biologists and physicians

    Stress avulsion of the tibial tuberosity after tension band wiring of a patellar fracture: a case report

    Get PDF
    INTRODUCTION: To the best of our knowledge there is no other report of an elderly patient who was surgically treated for a patellar fracture with tension band wiring and who subsequently suffered from an avulsion fracture of the tibial tuberosity. The combination of a patellar fracture and avulsion of the patellar ligament has only been described as complication after bone-patellar tendon-bone anterior cruciate ligament reconstructions. However, due to demographic changes and more elderly patients treated this injury may become more frequent in future. CASE PRESENTATION: We present the case of an 81 year old female who sustained an oblique patellar fracture after a direct contact injury of the left knee when falling on ice. Consequently the patellar fracture was openly reduced and stabilized with tension band wiring. The follow-up was uneventful till three months after surgery when the patient noticed a spontaneous avulsion fracture of the tibial tuberosity (Ogden type 3). The tibial tuberosity fragment was reattached with two non-resorbable sutures looped around two modified AO cortical 3.5 mm long neck screws. Intraoperatively multiple bone cysts were seen. Biopsies were not taken to prevent further fragmentation of the tibial tuberosity. The patient was followed up with anteroposterior and lateral full weight bearing radiographs and clinical assessment at 6, 12 weeks and 6 months after surgery. Recovery was completely pain free with full satisfaction. CONCLUSION: In conclusion in elderly patients with a patella fracture a possible associated but not obvious fracture of the tibial tuberosity should be ruled out and the postoperative rehabilitation protocol after tension band wiring of the patella might have to be individually adjusted to bone quality and course of the fracture

    An unusual case of persistent groin pain after total hip arthroplasty: a case report

    Get PDF
    ABSTRACT: INTRODUCTION: Arthroplasty is a well-established routine elective surgical procedure in orthopaedics. To a great extent, diagnosis, treatment and post-operative rehabilitation in these patients is standardised. In a busy clinic, surgeons from time to time tend to focus their attention on common causes of joint pain, but it may lead them to overlook sinister but less common pathologies. Here we report a case of a patient with groin pain due to pre-operatively undetected pelvic metastases from a pyeloureteral carcinoma who underwent total hip arthroplasty. There are several case reports which deal with primary or secondary tumours which were either discovered at the time of replacement surgery or developed at the site of prosthesis years after total hip or knee replacement. To the best of our knowledge, this is the first case report in which a metastatic cancer was missed pre-operatively and intra-operatively both by the radiologist and by the orthopaedic surgeon and should be reported so that surgeons are reminded to be careful when dealing with seemingly routine cases. CASE PRESENTATION: A 79-year-old Caucasian woman presented to the arthroplasty clinic with groin pain. Initial radiographs showed subtle bilateral abnormalities in the pelvis. Neither the radiologist nor the orthopaedic surgeon recognized it. A diagnosis of osteoarthritis of the hip was established, and she underwent total hip arthroplasty. Despite initial improvement, the patient came back with worsening hip pain three months later. Further radiological examination revealed multiple metastatic lesions throughout the pelvis due to a pyeloureteral carcinoma. CONCLUSIONS: This case report emphasizes the importance of meticulous, unbiased pre-operative assessment of patients and their radiographs, even in so-called routine clinical cases. Often subtle radiological changes are classed as normal, especially if they are bilateral. Further radiological imaging should be recommended in all cases where unexplained clinical features or radiological findings are present

    Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA).</p> <p>Methods</p> <p>Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10) and its anatomical distribution was mapped using a validated localization scheme. Univariate analysis (Wilcoxon-Mann-Whitney, Spearmean`s-rho test, p < 0.05) was performed to identify any correlations between component position, tracer uptake and diagnosis.</p> <p>Results</p> <p>SPECT/CT imaging changed the suspected diagnosis and the proposed treatment in 19/23 (83%) knees. Progression of patellofemoral OA (n = 11), loosening of the tibial (n = 3) and loosening of the femoral component (n = 2) were identified as the leading causes of pain after TKA.</p> <p>Patients with externally rotated tibial trays showed higher tracer uptake in the medial patellar facet (p = 0.049) and in the femur (p = 0.051). Patients with knee pain due to patellofemoral OA showed significantly higher tracer uptake in the patella than others (p < 0.001).</p> <p>Conclusions</p> <p>SPECT/CT was very helpful in establishing the diagnosis and guiding subsequent management in patients with painful knees after TKA, particularly in patients with patellofemoral problems and malpositioned or loose TKA.</p
    • …
    corecore