396 research outputs found

    Hybrid rocket performance

    Get PDF
    A hybrid rocket is a system consisting of a solid fuel grain and a gaseous or liquid oxidizer. Figure 1 shows three popular hybrid propulsion cycles that are under current consideration. NASA MSFC has teamed with industry to test two hybrid propulsion systems that will allow scaling to motors of potential interest for Titan and Atlas systems, as well as encompassing the range of interest for SEI lunar ascent stages and National Launch System Cargo Transfer Vehicle (NLS CTV) and NLS deorbit systems. Hybrid systems also offer advantages as moderate-cost, environmentally acceptable propulsion system. The objective of this work was to recommend a performance prediction methodology for hybrid rocket motors. The scope included completion of: a literature review, a general methodology, and a simplified performance model

    A Historical Systems Study of Liquid Rocket Engine Throttling Capabilities

    Get PDF
    This is a comprehensive systems study to examine and evaluate throttling capabilities of liquid rocket engines. The focus of this study is on engine components, and how the interactions of these components are considered for throttling applications. First, an assessment of space mission requirements is performed to determine what applications require engine throttling. A background on liquid rocket engine throttling is provided, along with the basic equations that are used to predict performance. Three engines are discussed that have successfully demonstrated throttling. Next, the engine system is broken down into components to discuss special considerations that need to be made for engine throttling. This study focuses on liquid rocket engines that have demonstrated operational capability on American space launch vehicles, starting with the Apollo vehicle engines and ending with current technology demonstrations. Both deep throttling and shallow throttling engines are discussed. Boost and sustainer engines have demonstrated throttling from 17% to 100% thrust, while upper stage and lunar lander engines have demonstrated throttling in excess of 10% to 100% thrust. The key difficulty in throttling liquid rocket engines is maintaining an adequate pressure drop across the injector, which is necessary to provide propellant atomization and mixing. For the combustion chamber, cooling can be an issue at low thrust levels. For turbomachinery, the primary considerations are to avoid cavitation, stall, surge, and to consider bearing leakage flows, rotordynamics, and structural dynamics. For valves, it is necessary to design valves and actuators that can achieve accurate flow control at all thrust levels. It is also important to assess the amount of nozzle flow separation that can be tolerated at low thrust levels for ground testing

    RP-1 and JP-8 Thermal Stability Experiments

    Get PDF
    This work experimentally investigates the effect of fuel composition changes on jet and rocket fuel thermal stability. A High Reynolds Number Thermal Stability test device evaluated JP-8 and RP-1 fuels. The experiment consisted of an electrically heated, stainless steel capillary tube with a controlled fuel outlet temperature. An optical pyrometer monitored the increasing external temperature profiles of the capillary tube as deposits build inside during each test. Multiple runs of each fuel composition provided results on measurement repeatability. Testing a t two different facilities provided data on measurement reproducibility. The technique is able to distinguish between thermally stable and unstable compositions of JP-8 and intermediate blends made by combining each composition. The technique is also able to distinguish among standard RP-1 rocket fuels and those having reduced sulfur levels. Carbon burn off analysis of residue in the capillary tubes on the RP-1 fuels correlates with the external temperature results

    The onsite manufacture of propellant oxygen from lunar resources

    Get PDF
    The Aerojet carbothermal process for the manufacture of oxygen from lunar materials has three essential steps: the reduction of silicate with methane to form carbon monoxide and hydrogen; the reduction of carbon monoxide with hydrogen to form methane and water; and the electrolysis of water to form hydrogen and oxygen. The reactions and the overall process are shown. It is shown with laboratory experimentation that the carbothermal process is feasible. Natural silicates can be reduced with carbon or methane. The important products are carbon monoxide, metal, and slag. The carbon monoxide can be completely reduced to form methane and water. The water can be electrolyzed to produce hydrogen and oxygen. A preliminary engineering study shows that the operation of plants using this process for the manufacture of propellant oxygen has a large economic advantage when the cost of the plant and its operation is compared to the cost of delivering oxygen from Earth

    Changes in the Radiometric Sensitivity of SeaWiFS

    Get PDF
    We report on the lunar and solar measurements used to determine the changes in the radiometric sensitivity of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS). Radiometric sensitivity is defined as the output from the instrument (or from one of the instrument bands) per unit spectral radiance at the instrument's input aperture. Knowledge of the long-term repeatability of the SeaWiFS measurements is crucial to maintaining the quality of the ocean scenes derived from measurements by the instrument. For SeaWiFS bands 1 through 6 (412 nm through 670 rim), the change in radiometric sensitivity is less than 0.2% for the period from November 1997 through November 1998. For band 7 (765 nm), the change is about 1.5%, and for band 8 (865 nm) about 5%. The rates of change of bands 7 and 8, which were linear with time for the first eight months of lunar measurements, are now slowing. The scatter in the data points about the trend lines in this analysis is less than 0.3% for all eight SeaWiFS bands. These results are based on monthly measurements of the moon. Daily solar measurements using an onboard diffuser show that the radiometric sensitivities of the SeaWiFS bands have changed smoothly during the time intervals between lunar measurements. Since SeaWiFS measurements have continued past November 1998, the results presented here are considered as a snapshot of the instrument performance as of that date

    Stability and Reversibility of Lithium Borohydrides Doped by Metal Halides and Hydrides

    Get PDF
    In an effort to develop reversible metal borohydrides with high hydrogen storage capacities and low dehydriding temperature, doping LiBH4 with various metal halides and hydrides has been conducted. Several metal halides such as TiCl3, TiF3, and ZnF2 effectively reduced the dehydriding temperature through a cation exchange interaction. Some of the halide doped LiBH4 are partially reversible. The LiBH4 + 0.1TiF3 desorbed 3.5 wt % and 8.5 wt % hydrogen at 150 and 450 °C, respectively, with subsequent reabsorption of 6 wt % hydrogen at 500 °C and 70 bar observed. XRD and NMR analysis of the rehydrided samples confirmed the reformation of LiBH4. The existence of the (B12H12)−2 species in dehydrided and rehydrided samples gives insight into the resultant partial reversibility. A number of other halides, MgF2, MgCl2, CaCl2, SrCl2, and FeCl3, did not reduce the dehydriding temperature of LiBH4 significantly. XRD and TGA-RGA analyses indicated that an increasing proportion of halides such as TiCl3, TiF3, and ZnCl2 from 0.1 to 0.5 mol makes lithium borohydrides less stable and volatile. Although the less stable borohydrides such as LiBH4 + 0.5TiCl3, LiBH4 + 0.5TiF3, and LiBH4 + 0.5ZnCl2 release hydrogen at room temperature, they are not reversible due to unrecoverable boron loss caused by diborane emission. In most cases, doping that produced less stable borohydrides also reduced the reversible hydrogen uptake. It was also observed that halide doping changed the melting points and reduced air sensitivity of lithium borohydrides

    A multi-modal intervention for Activating Patients at Risk for Osteoporosis (APROPOS): Rationale, design, and uptake of online study intervention material

    Get PDF
    OBJECTIVE: To develop an innovative and effective educational intervention to inform patients about the need for osteoporosis treatment and to determine factors associated with its online uptake. METHODS: Postmenopausal women with a prior fracture and not currently using osteoporosis therapy were eligible to be included in the Activating Patients at Risk for OsteoPOroSis (APROPOS). Four nominal groups with a total of 18 racially/ethnically diverse women identified osteoporosis treatment barriers. We used the Information, Motivation, Behavior Skills conceptual model to develop a direct-to-patient intervention to mitigate potentially modifiable barriers to osteoporosis therapy. The intervention included videos tailored by participants\u27 race/ethnicity and their survey responses: ranked barriers to osteoporosis treatment, deduced barriers to treatment, readiness to behavior change, and osteoporosis treatment history. Videos consisted of storytelling narratives, based on osteoporosis patient experiences and portrayed by actresses of patient-identified race/ethnicity. We also delivered personalized brief phone calls followed by an interactive voice-response phone messages aimed to promote uptake of the videos. RESULTS: To address the factors associated with online intervention uptake, we focused on participants assigned to the intervention arm (n = 1342). These participants were 92.9% Caucasian, with a mean (SD) age 74.9 (8.0) years and the majority (77.7%) had some college education. Preference for natural treatments was the barrier ranked #1 by most (n = 130; 27%), while concern about osteonecrosis of the jaw was the most frequently reported barrier (at any level; n = 322; 67%). Overall, 28.1% (n = 377) of participants in the intervention group accessed the videos online. After adjusting for relevant covariates, the participants who provided an email address had 6.07 (95% CI 4.53-8.14) higher adjusted odds of accessing their online videos compared to those who did not. CONCLUSION: We developed and implemented a novel tailored multi-modal intervention to improve initiation of osteoporosis therapy. An email address provided on the survey was the most important factor independently associated with accessing the intervention online. The design and uptake of this intervention may have implications for future studies in osteoporosis or other chronic diseases

    Impact of medical and neurological ICU complications on moderate-severe traumatic brain injury (TBI)

    Get PDF
    Certain admission characteristics are known predictors of adverse outcomes in patients with moderate-severe TBI, but explain only 1/3 of outcome variability. Intensive care unit (ICU) complications occur frequently in this population, but their impact on patient outcomes remains poorly defined. In a prospective observational cohort study of 170 consecutive moderate-severe TBI patients admitted to Level I trauma center (UMASS) over the period 11/2009–2/2012, we examined the association of ICU complications and 3-month outcome (Glasgow Outcome Scale [GOS]). The mean age was 51 years, 72% were men, and the median GCS and injury severity scores were 4 and 29, respectively. Using multiple logistic regression analysis, hypotension requiring vasopressors (HRV) was the strongest predictor of poor outcome (GOS 1-3 [OR 2.8; 95% CI 1-7.5]) among medical complications. After combining medical with neurological ICU complications, brain herniation (OR 5.8; 95% CI 1.1-30.2) and intracranial rebleeding (OR 2.9; 95% CI 1-8.4) were the strongest predictors of poor outcome, while HRV approached significance (OR 2.4; 95% CI 0.9-6.4). We identified important potentially modifiable predictors of adverse outcomes after moderate-severe TBI. Confirmation of our findings in a larger cohort is warranted

    Incidence rates of ICU complications in moderate-severe traumatic brain injury (TBI)

    Get PDF
    Retrospective studies suggest that non-neurologic organ failure may contribute to 2/3 of all deaths after TBI, but the actual incidence rates of specific intensive care unit (ICU) complications in moderate-severe TBI are not known. In a prospective observational cohort study of consecutive TBI patients from a single Level I trauma center (UMASS) over the period 11/2009 – 2/2012, we identified the ten most common medical complications after ICU admission according to strict pre-specified criteria in 170 moderate-severe TBI patients. The mean age of the study sample was 51 years, 72% were men, and the median GCS and injury severity scores were 4 and 29, respectively. Incidence rates of the ten most common medical complications in the ICU were: hyperglycemia (75%), fever (62%), systemic inflammatory response syndrome (38%), cardiac complications (36%), hypotension requiring vasopressors (35%), pneumonia (any type [34%]); sepsis (33%), anemia requiring transfusion (31%), other pulmonary complications (ARDS, pulmonary edema [26%]), and hyponatremia (sodium ≤134mEq/L; [23%]). Medical complications in moderate-severe TBI are very common, and their association with important patient outcomes should be further investigated. Specific medical complications may pose attractive modifiable treatment targets to improve the outcome of moderate-severe TBI patients

    Uncertainty Assessment of the SeaWiFS On-Orbit Calibration

    Get PDF
    Ocean color climate data records require water-leaving radiances with 5% absolute and 1% relative accuracies as input. Because of the amplification of any sensor calibration errors by the atmospheric correction, the 1% relative accuracy requirement translates into a 0.1% long-term radiometric stability requirement for top-of-the atmosphere radiances. The rigorous on-orbit calibration program developed and implemented for SeaWiFS by the NASA Ocean Biology Processing Group (OBPG) Calibration and Validation Team (CVT) has allowed the CVT to maintain the stability of the radiometric calibration of SeaWiFS at 0.13% or better over the mission. The uncertainties in the resulting calibrated top-of-the-atmosphere (TOA) radiances can be addressed in terms of accuracy (biases in the measurements), precision (scatter in the measurements), and stability (repeatability of the measurements). The calibration biases of lunar observations relative to the USGS RObotic Lunar Observatory (ROLO) photometric model of the Moon are 2-3%. The biases from the vicarious calibration against the Marine Optical Buoy (MOBY) are 1-2%. The precision of the calibration derived from the solar calibration signal-tonoise ratios are 0.16%, from the lunar residuals are 0.13%, and from the vicarious gains are 0.10%. The long-term stability of the TOA radiances, derived from the lunar time series, is 0.13%. The stability of the vicariouslycalibrated TOA radiances, incorporating the uncertainties in the MOBY measurements and the atmospheric correction, is 0.30%. These results allow the OBPG to produce climate data records from the SeaWiFS ocean color data
    corecore