3,941 research outputs found

    Comparative evaluation of [(99m)tc]tilmanocept for sentinel lymph node mapping in breast cancer patients: results of two phase 3 trials.

    Get PDF
    BackgroundSentinel lymph node (SLN) surgery is used worldwide for staging breast cancer patients and helps limit axillary lymph node dissection. [(99m)Tc]Tilmanocept is a novel receptor-targeted radiopharmaceutical evaluated in 2 open-label, nonrandomized, within-patient, phase 3 trials designed to assess the lymphatic mapping performance.MethodsA total of 13 centers contributed 148 patients with breast cancer. Each patient received [(99m)Tc]tilmanocept and vital blue dye (VBD). Lymph nodes identified intraoperatively as radioactive and/or blue stained were excised and histologically examined. The primary endpoint, concordance (lower boundary set point at 90 %), was the proportion of nodes detected by VBD and [(99m)Tc]tilmanocept.ResultsA total of 13 centers contributed 148 patients who were injected with both agents. Intraoperatively, 207 of 209 nodes detected by VBD were also detected by [(99m)Tc]tilmanocept for a concordance rate of 99.04 % (p < 0.0001). [(99m)Tc]tilmanocept detected a total of 320 nodes, of which 207 (64.7 %) were detected by VBD. [(99m)Tc]Tilmanocept detected at least 1 SLN in more patients (146) than did VBD (131, p < 0.0001). In 129 of 131 patients with ≥1 blue node, all blue nodes were radioactive. Of 33 pathology-positive nodes (18.2 % patient pathology rate), [(99m)Tc]tilmanocept detected 31 of 33, whereas VBD detected only 25 of 33 (p = 0.0312). No pathology-positive SLNs were detected exclusively by VBD. No serious adverse events were attributed to [(99m)Tc]tilmanocept.Conclusion[(99m)Tc]Tilmanocept demonstrated success in detecting a SLN while meeting the primary endpoint. Interestingly, [(99m)Tc]tilmanocept was additionally noted to identify more SLNs in more patients. This localization represented a higher number of metastatic breast cancer lymph nodes than that of VBD

    Dental Light-curing Units: An American Dental Association Clinical Evaluators Panel Survey

    Get PDF
    Background The ability to polymerize light-activated dental materials with dental light-curing units (DLCUs) has revolutionized dentistry. However, proper DLCU use is essential for ensuring the effectiveness and performance of these materials. Methods The authors developed an electronic cross-sectional survey in the American Dental Association Qualtrics Research Core platform. The survey included questions about DLCU use, unit type and selection, training, maintenance, technique, and safety measures. The authors deployed the survey to 809 American Dental Association Clinical Evaluators (ACE) panelists on October 9, 2019, and sent reminder links to nonrespondents 1 week later. They conducted exploratory and descriptive analyses using SAS software Version 9.4. Results Of the 353 ACE panelists who completed the survey, most used a DLCU in their practices (99%), and light-emitting diode multiwave units were the most common type of DLCU units (55%). Dentists use DLCUs for over one-half of their appointments each day (mean [standard deviation], 59% [22%]). Regarding technique, respondents reported that they modify their curing technique on the basis of material thickness (79%) and material type or light tip-to-target distances (59%). Maintenance practices varied, with two-thirds of respondents reporting that they periodically check their DLCUs\u27 light output. Conclusions DLCUs are an integral part of a general dentist’s daily practice, but maintenance, ocular safety, and technique varied widely among this sample. Practical Implications Because clinical effectiveness requires delivery of an adequate amount of light energy at the appropriate wavelength, variation in DLCU maintenance, safety, and techniques suggest that dentists could benefit from additional guidance and training on DLCU operation

    Long-term effectiveness of PROMPT treatment in a severely apractic-aphasic speaker

    Get PDF
    This study examined the acquisition and long-term maintenance of a functional core vocabulary by a severely apractic-aphasic speaker following the application of Prompts for Restructuring Oral Muscular Phonetic Targets (PROMPT) treatment. The subject was a 24-year-old male who had suffered a single left- hemisphere thrombotic CVA approximately 2 years prior to the beginning of this investigation. Treatment and maintenance were monitored over a 41-week period. The results showed that the 30 target words and phrases were produced accurately during the treatment phases of the study and after treatment was discontinued

    Bonding Crowns and Bridges with Resin Cement

    Get PDF
    Background Bonding crowns and bridges with resin cement can improve retention and reinforcement of the restoration. However, there is variation in the steps taken by different practitioners to achieve this goal. Methods The authors developed a survey on bonding dental crowns and bridges with resin cement and distributed it electronically to the American Dental Association Clinical Evaluators (ACE) Panel on May 22, 2020. The survey remained open for 2 weeks. Descriptive data analysis was conducted using SAS Version 9.4. Results A total of 326 panelists responded to the survey, and 86% of respondents who place crowns or bridges use resin cements for bonding. When placing a lithium disilicate restoration, an almost equal proportion of respondents etch it with hydrofluoric acid in their office or asked the laboratory to do it for them, and more than two-thirds use a silane primer before bonding. For zirconia restorations, 70% reported their restorations are sandblasted in the laboratory, and 39% use a primer containing 10-methacryloyloxydecyl dihydrogen phosphate. One-half of respondents clean their lithium disilicate or zirconia restorations with a cleaning solution. Resin cements used with a primer in the etch-and-rinse mode are the most widely used. The technique used to cure and clean excess resin cement varies among respondents. Conclusions The types of resin cements used, tooth preparation, crown or bridge preparation, and bonding technique vary among this sample. Practical Implications Although many dentists bond crowns and bridges on the basis of best practices, improvement in the process may be achieved by dentists communicating with their laboratory to confirm the steps performed there, ensuring an effective cleaning technique is used after try-in and verifying that the correct primer is used with their chosen restorative material

    Spatial and temporal changes in cumulative human impacts on the world's ocean

    Get PDF
    Human pressures on the ocean are thought to be increasing globally, yet we know little about their patterns of cumulative change, which pressures are most responsible for change, and which places are experiencing the greatest increases. Managers and policymakers require such information to make strategic decisions and monitor progress towards management objectives. Here we calculate and map recent change over 5 years in cumulative impacts to marine ecosystems globally from fishing, climate change, and ocean- and land-based stressors. Nearly 66% of the ocean and 77% of national jurisdictions show increased human impact, driven mostly by climate change pressures. Five percent of the ocean is heavily impacted with increasing pressures, requiring management attention. Ten percent has very low impact with decreasing pressures. Our results provide large-scale guidance about where to prioritize management efforts and affirm the importance of addressing climate change to maintain and improve the condition of marine ecosystems

    Are autistic traits measured equivalently in individuals with and without an Autism Spectrum Disorder?:An invariance analysis of the Autism Spectrum Quotient Short Form

    Get PDF
    It is common to administer measures of autistic traits to those without autism spectrum disorders (ASDs) with, for example, the aim of understanding autistic personality characteristics in non-autistic individuals. Little research has examined the extent to which measures of autistic traits actually measure the same traits in the same way across those with and without an ASD. We addressed this question using a multi-group confirmatory factor invariance analysis of the Autism Quotient Short Form (AQ-S: Hoekstra et al. in J Autism Dev Disord 41(5):589-596, 2011) across those with (n = 148) and without (n = 168) ASD. Metric variance (equality of factor loadings), but not scalar invariance (equality of thresholds), held suggesting that the AQ-S measures the same latent traits in both groups, but with a bias in the manner in which trait levels are estimated. We, therefore, argue that the AQ-S can be used to investigate possible causes and consequences of autistic traits in both groups separately, but caution is due when combining or comparing levels of autistic traits across the two group

    Genetic risk scores associated with baseline lipoprotein subfraction concentrations do not associate with their responses to fenofibrate

    Get PDF
    Lipoprotein subclass concentrations are modifiable markers of cardiovascular disease risk. Fenofibrate is known to show beneficial effects on lipoprotein subclasses, but little is known about the role of genetics in mediating the responses of lipoprotein subclasses to fenofibrate. A recent genomewide association study (GWAS) associated several single nucleotide polymorphisms (SNPs) with lipoprotein measures, and validated these associations in two independent populations. We used this information to construct genetic risk scores (GRSs) for fasting lipoprotein measures at baseline (pre-fenofibrate), and aimed to examine whether these GRSs also associated with the responses of lipoproteins to fenofibrate. Fourteen lipoprotein subclass measures were assayed in 817 men and women before and after a three week fenofibrate trial. We set significance at a Bonferroni corrected alpha <0.05 (p < 0.004). Twelve subclass measures changed with fenofibrate administration (each p = 0.003 to <0.0001). Mixed linear models which controlled for age, sex, body mass index (BMI), smoking status, pedigree and study-center, revealed that GRSs were associated with eight baseline lipoprotein measures (p < 0.004), however no GRS was associated with fenofibrate response. These results suggest that the mechanisms for changes in lipoprotein subclass concentrations with fenofibrate treatment are not mediated by the genetic risk for fasting levels

    Milk consumption and the prepubertal somatotropic axis

    Get PDF
    © 2007 Rich-Edwards et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution Licens

    A clustering analysis of lipoprotein diameters in the metabolic syndrome

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The presence of smaller low-density lipoproteins (LDL) has been associated with atherosclerosis risk, and the insulin resistance (IR) underlying the metabolic syndrome (MetS). In addition, some research has supported the association of very low-, low- and high-density lipoprotein (VLDL HDL) particle diameters with components of the metabolic syndrome (MetS), although this has been the focus of less research. We aimed to explore the relationship of VLDL, LDL and HDL diameters to MetS and its features, and by clustering individuals by their diameters of VLDL, LDL and HDL particles, to capture information across all three fractions of lipoprotein into a unified phenotype.</p> <p>Methods</p> <p>We used nuclear magnetic resonance spectroscopy measurements on fasting plasma samples from a general population sample of 1,036 adults (mean ± SD, 48.8 ± 16.2 y of age). Using latent class analysis, the sample was grouped by the diameter of their fasting lipoproteins, and mixed effects models tested whether the distribution of MetS components varied across the groups.</p> <p>Results</p> <p>Eight discrete groups were identified. Two groups (N = 251) were enriched with individuals meeting criteria for the MetS, and were characterized by the smallest LDL/HDL diameters. One of those two groups, one was additionally distinguished by large VLDL, and had significantly higher blood pressure, fasting glucose, triglycerides, and waist circumference (WC; <it>P </it>< .001). However, large VLDL, in the absence of small LDL and HDL particles, did not associate with MetS features. These associations held after additionally controlling for VLDL, LDL and HDL particle concentrations.</p> <p>Conclusions</p> <p>While small LDL diameters remain associated with IR and the MetS, the occurrence of these in conjunction with a shift to overall larger VLDL diameter may identify those with the highest fasting glucose, TG and WC within the MetS. If replicated, the association of this phenotype with more severe IR-features indicated that it may contribute to identifying of those most at risk for incident type II diabetes and cardiometabolic disease.</p
    corecore