10 research outputs found

    A patient-specific measurement technique to model shoulder joint kinematics

    Get PDF
    Measuring dynamic in vivo shoulder kinematics is crucial to better understanding numerous pathologies. Motion capture systems using skin-mounted markers offer good solutions for non-invasive assessment of shoulder kinematics during dynamic movement. However, none of the current motion capture techniques have been used to study translation values at the joint, which is crucial to assess shoulder instability. The aim of the present study was to develop a dedicated patient-specific measurement technique based on motion capture and magnetic resonance imaging (MRI) to determine shoulder kinematics accurately

    Analysis of hip range of motion in everyday life ::a pilot study

    No full text
    Patients undergoing total hip arthroplasty are increasingly younger and have a higher demand concerning hip range of motion. To date, there is no clear consensus as to the amplitude of the “normal hip” in everyday life. It is also unknown if the physical examination is an accurate test for setting the values of true hip motion. The purpose of this study was: 1) to precisely determine the necessary hip joint mobility for everyday tasks in young active subjects to be used in computer simulations of prosthetic models in order to evaluate impingement and instability during their practice; 2) to assess the accuracy of passive hip range of motion measurements during clinical examination. A total of 4 healthy volunteers underwent Magnetic Resonance Imaging and 2 motion capture experiments. During experiment 1, routine activities were recorded and applied to prosthetic hip 3D models including nine cup configurations. During experiment 2, a clinical examination was performed, while the motion of the subjects was simultaneously captured. Important hip flexion (mean range 95°-107°) was measured during daily activities that could expose the prosthetic hip to impingement and instability. The error made by the clinicians during physical examination varied in the range of ±10°, except for flexion and abduction where the error was higher. This study provides useful information for the surgical planning to help restore hip mobility and stability, when dealing with young active patients. The physical examination seems to be a precise method for determining passive hip motion, if care is taken to stabilise the pelvis during hip flexion and abduction

    Assessment of congruence and impingement of the hip joint in professional ballet dancers: a motion capture study

    No full text
    Early hip osteoarthritis in dancers could be explained by femoroacetabular impingements. However, there is a lack of validated noninvasive methods and dynamic studies to ascertain impingement during motion. Moreover, it is unknown whether the femoral head and acetabulum are congruent in typical dancing positions

    Swiss-wide multicentre evaluation and prediction of core outcomes in arthroscopic rotator cuff repair: protocol for the ARCR_Pred cohort study

    No full text
    Introduction In the field of arthroscopic rotator cuff repair (ARCR), reporting standards of published studies differ dramatically, notably concerning adverse events (AEs). In addition, prognostic studies are overall methodologically poor, based on small data sets and explore only limited numbers of influencing factors. We aim to develop prognostic models for individual ARCR patients, primarily for the patient-reported assessment of shoulder function (Oxford Shoulder Score (OSS)) and the occurrence of shoulder stiffness 6 months after surgery. We also aim to evaluate the use of a consensus core event set (CES) for AEs and validate a severity classification for these events, considering the patient’s perspective.Methods and analysis A cohort of 970 primary ARCR patients will be prospectively documented from several Swiss and German orthopaedic clinics up to 24 months postoperatively. Patient clinical examinations at 6 and 12 months will include shoulder range of motion and strength (Constant Score). Tendon repair integrity status will be assessed by ultrasound at 12 months. Patient-reported questionnaires at 6, 12 and 24 months will determine functional scores (subjective shoulder value, OSS), anxiety and depression scores, working status, sports activities, and quality of life (European Quality of Life 5 Dimensions 5 Level questionnaire). AEs will be documented according to a CES. Prognostic models will be developed using an internationally supported regression methodology. Multiple prognostic factors, including patient baseline demographics, psychological, socioeconomic and clinical factors, rotator cuff integrity, concomitant local findings, and (post)operative management factors, will be investigated.Ethics and dissemination This project contributes to the development of personalised risk predictions for supporting the surgical decision process in ARCR. The consensus CES may become an international reference for the reporting of complications in clinical studies and registries. Ethical approval was obtained on 1 April 2020 from the lead ethics committee (EKNZ, Basel, Switzerland; ID: 2019-02076). All participants will provide informed written consent before enrolment in the study.Trial registration number NCT04321005.Protocol version Version 2 (13 December 2019)
    corecore