36 research outputs found

    Human lung adenocarcinoma cell cultures derived from malignant pleural effusions as model system to predict patients chemosensitivity

    Get PDF
    BACKGROUND: Lung cancer is the leading cause of cancer related deaths and Malignant Pleural Effusion (MPE) is a frequent complication. Current therapies suffer from lack of efficacy in a great percentage of cases, especially when cancer is diagnosed at a late stage. Moreover patients' responses vary and the outcome is unpredictable. Therefore, the identification of patients who will benefit most of chemotherapy treatment is important for accurate prognostication and better outcome. In this study, using malignant pleural effusions (MPE) from non-small cell lung cancer (NSCLC) patients, we established a collection of patient-derived Adenocarcinoma cultures which were characterized for their sensitivity to chemotherapeutic drugs used in the clinical practice. METHODS: Tumor cells present in MPEs of patients with NSCLC were isolated by density gradient centrifugation, placed in culture and genotyped by next generation sequencing. In a subset of cases patient derived xenografts (PDX) were obtained upon tumor cell inoculation in rag2/IL2 knock-out mice. Isolated primary cultures were characterized and tested for drug sensitivity by in vitro proliferation assays. Additivity, antagonism or synergy for combinatorial treatments were determined by analysis with the Calcusyn software. RESULTS: We have optimized isolation procedures and culture conditions to expand in vitro primary cultures from Malignant Pleural Effusions (MPEs) of patients affected by lung adenocarcinomas, the most frequent form of non small cell lung cancer. Using this approach we have been able to establish 16 primary cultures from MPEs. Cells were banked at low passages and were characterized for their mutational pattern by next generation sequencing for most common driver mutations in lung cancer. Moreover, amplified cultures were shown to engraft with high efficiency when injected in immunocompromised mice. Cancer cell sensitivity to drugs used in standard chemotherapy regimens was assessed either individually or in combination. Differential chemosensitivity and different mutation profiles were observed which suggests that this isolation method could provide a platform for predicting the efficacy of chemotherapy in the clinical setting. Most importantly for six patients it was possible to establish a correlation between drug response in vitro and response to therapy in the clinic. CONCLUSIONS: Results obtained using primary cultured cells from MPEs underscore the heterogeneity of NSCLC in advanced stage as indicated by drug response and mutation profile. Comparison of data obtained from in vitro assays with patients' responses to therapy leads to the conclusion that this strategy may provide a potentially useful approach for evaluating individual chemosensitivity profile and tailor the therapy accordingly. Furthermore, combining MPE-derived primary cultures with their genomic testing allows to identify patients eligible to trials with novel targeted agents

    IQN path ASBL report from the first European cfDNA consensus meeting:expert opinion on the minimal requirements for clinical ctDNA testing

    Get PDF
    Liquid biopsy testing is a new laboratory-based method that detects tumour mutations in circulating free DNA (cfDNA) derived from minimally invasive blood sampling techniques. Recognising the significance for clinical testing, in 2017, IQN Path provided external quality assessment for liquid biopsy testing. Representatives of those participating laboratories were invited to attend a workshop to discuss the findings and how to achieve quality implementation of cfDNA testing in the clinical setting, the discussion and outcomes of this consensus meeting are described below. Predictive molecular profiling using tumour tissue in order to select cancer patients eligible for targeted therapy is now routine in diagnostic pathology. If insufficient tumour tissue material is available, in some circumstances, recent European Medicines Agency (EMA) guidance recommends mutation testing with plasma cfDNA. Clinical applications of cfDNA include treatment selection based on clinically relevant mutations derived from pre-treatment samples and the detection of resistant mutations upon progression of the disease. In order to identify tumour-related mutations in amongst other nucleic acid material found in plasma samples, highly sensitive laboratory methods are needed. In the workshop, we discussed the variable approaches taken with regard to cfDNA extraction methods, the tests, and considered the impact of false-negative test results. We explored the lack of standardisation of complex testing procedures ranging from plasma collection, transport, processing and storage, cfDNA extraction, and mutation analysis, to interpretation and reporting of results. We will also address the current status of clinical validation and clinical utility, and its use in current diagnosis. This workshop revealed a need for guidelines on with standardised procedures for clinical cfDNA testing and reporting, and a requirement for cfDNA-based external quality assessment programs

    International pilot external quality assessment scheme for analysis and reporting of circulating tumour DNA

    Get PDF
    Background Molecular analysis of circulating tumour DNA (ctDNA) is becoming increasingly important in clinical treatment decisions. A pilot External Quality Assessment (EQA) scheme for ctDNA analysis was organized by four European EQA providers under the umbrella organization IQN Path, in order to investigate the feasibility of delivering an EQA to assess the detection of clinically relevant variants in plasma circulating cell-free DNA (cfDNA) and to analyze reporting formats. Methods Thirty-two experienced laboratories received 5 samples for EGFR mutation analysis and/or 5 samples for KRAS and NRAS mutation analysis. Samples were artificially manufactured to contain 3 mL of human plasma with 20 ng/mL of fragmented ctDNA and variants at allelic frequencies of 1 and 5%. Results The scheme error rate was 20.1%. Higher error rates were observed for RAS testing when compared to EGFR analysis, for allelic frequencies of 1% compared to 5%, and for cases including 2 different variants. The reports over-interpreted wild-type results and frequently failed to comment on the amount of cfDNA extracted. Conclusions The pilot scheme demonstrated the feasibility of delivering a ctDNA EQA scheme and the need for such a scheme due to high error rates in detecting low frequency clinically relevant variants. Recommendations to improve reporting of cfDNA are provided

    The Italian external quality assessment for RAS testing in colorectal carcinoma identifies methods-related inter-laboratory differences

    No full text
    BACKGROUND: In 2014 the European Medicines Agency included exon 2, 3 and 4 KRAS and NRAS testing for the selection of metastatic colorectal cancer (mCRC) patients eligible for the therapy with anti-EGFR monoclonal antibodies. The Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology and Cytology (SIAPEC) organized an external quality assessment (EQA) scheme for CRC to evaluate inter-laboratory consistency and to ensure standardization of the results in the transition from KRAS to all-RAS testing. METHODS: Ten formalin fixed paraffin embedded specimens including KRAS/NRAS (exons 2, 3, 4) and BRAF (codon 600) mutations were validated by three referral laboratories and sent to 88 participant centers. Molecular pathology sample reports were also requested to each laboratory. A board of assessors from AIOM and SIAPEC evaluated the results according to a predefined scoring system. The scheme was composed of two rounds. RESULTS: In the first round 36% of the 88 participants failed, with 23 centers having at least one false positive or false negative while 9 centers did not meet the deadline. The genotyping error rate was higher when Sanger sequencing was employed for testing as compared with pyrosequencing (3 vs 1.3%; p = 0.01; Pearson Chi Square test). In the second round, the laboratories improved their performance, with 23/32 laboratories passing the round. Overall, 79/88 participants passed the RAS EQA scheme. Standardized Human Genome Variation Society nomenclature was incorrectly used to describe the mutations identified and relevant variations were noticed in the genotype specification. CONCLUSION: The results of the Italian RAS EQA scheme indicate that the mutational analyses are performed with good quality in many Italian centers, although significant differences in the methods used were highlighted. The relatively high number of centers failing the first round underlines the fundamental role in continued education covered by EQA schemes

    CovidArray: A Microarray-Based Assay with High Sensitivity for the Detection of Sars-Cov-2 in Nasopharyngeal Swabs

    No full text
    A new coronavirus (SARS-CoV-2) caused the current coronavirus disease (Covid-19) epidemic. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) is used as the gold standard for clinical detection of SARS-CoV-2. Under ideal conditions, RT-qPCR Covid-19 assays have analytical sensitivity and specificity greater than 95%. However, when the sample panel is enlarged including asymptomatic individuals, the sensitivity decreases and false negatives are reported. Moreover, RT-qPCR requires up to 3–6 h with most of the time involved in RNA extraction from swab samples. We introduce CovidArray, a microarray-based assay, to detect SARS-CoV-2 markers N1 and N2 in the nasopharyngeal swabs. The method is based on solid-phase hybridization of fluorescently-labeled amplicons upon RNA extraction and reverse transcription. This approach combines the physical-optical properties of the silicon substrate with the surface chemistry used to coat the substrate to obtain a diagnostic tool of great sensitivity. Furthermore, we used an innovative approach, RNAGEM, to extract and purify viral RNA in less than 15 min. We correctly assigned 12 nasopharyngeal swabs, previously analyzed by RT-qPCR. Thanks to the CovidArray sensitivity we were able to identify a false-negative sample. CovidArray is the first DNA microarray-based assay to detect viral genes in the swabs. Its high sensitivity and the innovative viral RNA extraction by RNAGEM allows the reduction of both the amount of false-negative results and the total analysis time to about 2 h

    Results of a worldwide external quality assessment of cfDNA testing in lung Cancer

    Get PDF
    Background: Circulating cell free DNA (cfDNA) testing of plasma for EGFR somatic variants in lung cancer patients is being widely implemented and with any new service, external quality assessment (EQA) is required to ensure patient safety. An international consortium, International Quality Network for Pathology (IQNPath), has delivered a second round of assessment to measure the accuracy of cfDNA testing for lung cancer and the interpretation of the results. Methods: A collaboration of five EQA provider organisations, all members of IQNPath, have delivered the assessment during 2018–19 to a total of 264 laboratories from 45 countries. Bespoke plasma reference material containing a range of EGFR mutations at varying allelic frequencies were supplied to laboratories for testing and reporting according to routine procedures. The genotyping accuracy and clinical reporting was reviewed against standardised criteria and feedback was provided to participants. Results: The overall genotyping error rate in the EQA was found to be 11.1%. Low allelic frequency samples were the most challenging and were not detected by some testing methods, resulting in critical genotyping errors. This was reflected in higher false negative rates for samples with variant allele frequencies (VAF) rates less than 1.5% compared to higher frequencies. A sample with two different EGFR mutations gave inconsistent detection of both mutations. However, for one sample, where two variants were present at a VAF of less than 1% then both mutations were correctly detected in 145/263 laboratories. Reports often did not address the risk that tumour DNA may have not been tested and limitations of the methodologies provided by participants were insufficient. This was reflected in the average interpretation score for the EQA being 1.49 out of a maximum of 2. Conclusions: The variability in the standard of genotyping and reporting highlighted the need for EQA and educational guidance in this field to ensure the delivery of high-quality clinical services where testing of cfDNA is the only option for clinical management
    corecore