44 research outputs found

    Validation of a German Version of the Stress Overload Scale and Comparison of Different Time Frames in the Instructions

    Get PDF
    Abstract: Introduction: The Stress Overload Scale (SOS; Amirkhan, 2012 , 2018 ) was introduced as a two-factorial self-report measure of stress to overcome limitations of other scales. Methods: We developed a German translation of the SOS and validated it in addition to a short version and an extra-short version. Furthermore, we tested whether manipulating the time frame introduced as retention interval in the instructions affected its psychometric properties. Results: Using two independent age-heterogeneous convenience samples ( Ntotal = 1,239), we found good psychometric properties for a modified German short version of the SOS-S (SOS-S-G) and a new extra-short version (SOS-XS-G), but not for the German long version of the SOS. Moreover, manipulating the time frame of the SOS did not affect its psychometric quality. Discussion The SOS enriches the repertoire of self-report measures of stress as it captures the nonpathological core facets of stress in line with theoretical stress conceptualizations

    High-rate low-temperature dc pulsed magnetron sputtering of photocatalytic TiO2films: the effect of repetition frequency

    Get PDF
    The article reports on low-temperature high-rate sputtering of hydrophilic transparent TiO2thin films using dc dual magnetron (DM) sputtering in Ar + O2mixture on unheated glass substrates. The DM was operated in a bipolar asymmetric mode and was equipped with Ti(99.5) targets of 50 mm in diameter. The substrate surface temperature Tsurfmeasured by a thermostrip was less than 180 °C for all experiments. The effect of the repetition frequency frwas investigated in detail. It was found that the increase of frfrom 100 to 350 kHz leads to (a) an improvement of the efficiency of the deposition process that results in a significant increase of the deposition rate aDof sputtered TiO2films and (b) a decrease of peak pulse voltage and sustaining of the magnetron discharge at higher target power densities. It was demonstrated that several hundreds nm thick hydrophilic TiO2films can be sputtered on unheated glass substrates at aD = 80 nm/min, Tsurf < 180 °C when high value of fr = 350 kHz was used. Properties of a thin hydrophilic TiO2film deposited on a polycarbonate substrate are given

    11th German Conference on Chemoinformatics (GCC 2015) : Fulda, Germany. 8-10 November 2015.

    Get PDF

    Fast Parallel Ray-Tracing Simulator

    No full text

    Einrichtung zum Beschichten durch Magnetron-Sputtern

    No full text
    DE 10234856 A UPAB: 20040326 NOVELTY - Coating device comprises a target and a unit producing a magnetic field. The target is made from two concentrically arranged partial targets (1, 2) each made from the material to be deposited. Separating lines run between the partial targets parallel to the pole lines of the unit producing a magnetic field. The partial targets are electrically connected. The unit producing a magnetic field contains electromagnetic coils (3, 4) assigned to the partial targets and has devices which can change the position of the magnetic pole opposite the separating lines of the partial targets. USE - For depositing layers of alloys, mixtures or reaction products of at least two different materials by magnetron sputtering e.g. in electronics, display technology, tool coating, decorative coating and in optical applications. ADVANTAGE - The device is compact and produces layers having high uniformity, homogeneity and long-term stability

    Validation of a German Version of the Stress Overload Scale and Comparison of Different Time Frames in the Instructions

    No full text
    Introduction: The Stress Overload Scale (SOS; Amirkhan, 2012, 2018) was introduced as a two-factorial self-report measure of stress to overcome limitations of other scales. Methods: We developed a German translation of the SOS and validated it in addition to a short version and an extra-short version. Furthermore, we tested whether manipulating the time frame introduced as retention interval in the instructions affected its psychometric properties. Results: Using two independent age-heterogeneous convenience samples (N sub total = 1,239), we found good psychometric properties for a modified German short version of the SOS-S (SOS-S-G) and a new extra-short version (SOS-XS-G), but not for the German long version of the SOS. Moreover, manipulating the time frame of the SOS did not affect its psychometric quality. Discussion The SOS enriches the repertoire of self-report measures of stress as it captures the nonpathological core facets of stress in line with theoretical stress conceptualizations
    corecore