998 research outputs found

    Modeling of supramolecular biopolymers: Leading the <i>in silico</i> revolution of tissue engineering and nanomedicine

    Get PDF
    Abstract The field of tissue engineering is poised to be positively influenced by the advent of supramolecular biopolymers, because of their promising tailorability coming from the bottom-up approach used for their development, absence of toxic byproducts from their gelation reaction and intrinsic better mimicry of extracellular matrix nanotopography and mechanical properties. However, a deep understanding of the phenomena ruling their properties at the meso- and macroscales is still missing. In silico approaches are increasingly helping to shine a light on questions still of out of reach for almost all empirical methods. In this review, we will present the most significant and updated efforts on molecular modeling of SBP properties, and their interactions with the living counterparts, at all scales. In detail, the currently available molecular mechanic approaches will be discussed, paying attention to the pros and cons related to their representability and transferability. We will also give detailed insights for choosing different biomolecular modeling strategies at various scales. This is a systematic overview of tools and approaches yielding to advances at atomistic, molecular, and supramolecular levels, with a holistic perspective demonstrating the urgent need for theories and models connecting biomaterial design and their biological effect in vivo

    Role of hydrostatic paradoxes towards the formation of the scientific thought of students at academic level

    No full text
    The importance of fluid mechanics is often underrated. Besides studying the mechanisms governing static and dynamic fluids, this discipline could have a great role in the understanding of many principles, topics and concepts of general mechanics. When approached in a proper way, fluid mechanics provides numerous 'case studies' apt to clarify the physical content of several mechanical laws. Unfortunately, fluid mechanics, in physics classes, is generally viewed as a 'lower branch' of mechanics. Its rules and laws too often are regarded as too particular, or even as special cases, to deserve the same attention paid to other arguments. The help that fluid mechanics could return in the learning process can be proved by some easy considerations. In this frame, the so-called hydrostatic paradoxes could provide a tremendous contribution to the learning processes

    Perspective Preserving Solution for Quasi-Orthoscopic Video See-Through HMDs

    Get PDF
    In non-orthoscopic video see-through (VST) head-mounted displays (HMDs), depth perception through stereopsis is adversely affected by sources of spatial perception errors. Solutions for parallax-free and orthoscopic VST HMDs were considered to ensure proper space perception but at expenses of an increased bulkiness and weight. In this work, we present a hybrid video-optical see-through HMD the geometry of which explicitly violates the rigorous conditions of orthostereoscopy. For properly recovering natural stereo fusion of the scene within the personal space in a region around a predefined distance from the observer, we partially resolve the eye-camera parallax by warping the camera images through a perspective preserving homography that accounts for the geometry of the VST HMD and refers to such distance. For validating our solution; we conducted objective and subjective tests. The goal of the tests was to assess the efficacy of our solution in recovering natural depth perception in the space around said reference distance. The results obtained showed that the quasi-orthoscopic setting of the HMD; together with the perspective preserving image warping; allow the recovering of a correct perception of the relative depths. The perceived distortion of space around the reference plane proved to be not as severe as predicted by the mathematical models

    Performance and genome-centric metagenomics of thermophilic single and two-stage anaerobic digesters treating cheese wastes

    Get PDF
    The present research is the first comprehensive study regarding the thermophilic anaerobic degradation of cheese wastewater, which combines the evaluation of different reactor configurations (i.e. single and two-stage continuous stirred tank reactors) on the process efficiency and the in-depth characterization of the microbial community structure using genome-centric metagenomics. Both reactor configurations showed acidification problems under the tested organic loading rates (OLRs) of 3.6 and 2.4 g COD/L-reactor day and the hydraulic retention time (HRT) of 15 days. However, the two-stage design reached a methane yield equal to 95% of the theoretical value, in contrast with the single stage configuration, which reached a maximum of 33% of the theoretical methane yield. The metagenomic analysis identified 22 new population genomes and revealed that the microbial compositions between the two configurations were remarkably different, demonstrating a higher methanogenic biodiversity in the two-stage configuration. In fact, the acidogenic reactor of the serial configuration was almost solely composed by the lactose degrader Bifidobacterium crudilactis UC0001. The predictive functional analyses of the main population genomes highlighted specific metabolic pathways responsible for the AD process and the mechanisms of main intermediates production. Particularly, the acetate accumulation experienced by the single stage configuration was mainly correlated to the low abundant syntrophic acetate oxidizer Tepidanaerobacter acetatoxydans UC0018 and to the absence of aceticlastic methanogens

    Local anaesthesia efficacy as postoperative analgesia for open shoulder instability surgery. a prospective randomised controlled study

    Get PDF
    Background and objectives: The aim of present study was to evaluate for the first time, the clinical effect of local anaesthetic infiltration as postoperative analgesia in open shoulder surgery for anterior-inferior instability. The comparison of the local infiltration and interscalenic brachial plexus block to a control group test the local anaesthetic efficacy in this surgery. Methods: 78 patients scheduled for open shoulder surgery were enrolled and randomly assigned to one of three groups: local infiltration anaesthesia (LIA), interscalenic brachial plexus block (IBPB) and control (C). All patients received standardized general anaesthesia and all injections were performed with the same dose and volume of anaesthetic. The number boluses delivered by a PCA pump applied at the end of surgery and the visual analogue score (VAS) at 0, 2, 4, 6, 12, 18 and 24 hours after intervention were recorded. A patient satisfaction score was also assessed. Results: Mean bolus consumption of the rescue analgesic, compared to C, was significantly less both in the LIA and IBPB groups (P<0.05). The IBPB group showed VAS scores that were significantly better than C group at all time points (P<0.05). The VAS scores for LIA group were clinically comparable to IBPB, and only at the 2 and 6 hours, postoperative time points there were no significant differences found in respect to the C group. IBPB and LIA showed comparable patient satisfaction scores. Conclusion: The local anaesthetic infiltration as postoperative analgesia appears to be a clinically valid alternative, statistically comparable to IBPB, with no clinical meaningful adverse effects

    Suitability of ground-based SfM-MVS for monitoring glacial and periglacial processes

    Get PDF
    Photo-based surface reconstruction is rapidly emerging as an alternative survey technique to lidar (light detection and ranging) in many fields of geoscience fostered by the recent development of computer vision algorithms such as structure from motion (SfM) and dense image matching such as multi-view stereo (MVS). The objectives of this work are to test the suitability of the ground-based SfM-MVS approach for calculating the geodetic mass balance of a 2.1km2 glacier and for detecting the surface displacement of a neighbouring active rock glacier located in the eastern Italian Alps. The photos were acquired in 2013 and 2014 using a digital consumer-grade camera during single-day field surveys. Airborne laser scanning (ALS, otherwise known as airborne lidar) data were used as benchmarks to estimate the accuracy of the photogrammetric digital elevation models (DEMs) and the reliability of the method. The SfM-MVS approach enabled the reconstruction of high-quality DEMs, which provided estimates of glacial and periglacial processes similar to those achievable using ALS. In stable bedrock areas outside the glacier, the mean and the standard deviation of the elevation difference between the SfM-MVS DEM and the ALS DEM was-0.42 \ub1 1.72 and 0.03 \ub1 0.74 m in 2013 and 2014, respectively. The overall pattern of elevation loss and gain on the glacier were similar with both methods, ranging between-5.53 and + 3.48 m. In the rock glacier area, the elevation difference between the SfM-MVS DEM and the ALS DEM was 0.02 \ub1 0.17 m. The SfM-MVS was able to reproduce the patterns and the magnitudes of displacement of the rock glacier observed by the ALS, ranging between 0.00 and 0.48 m per year. The use of natural targets as ground control points, the occurrence of shadowed and low-contrast areas, and in particular the suboptimal camera network geometry imposed by the morphology of the study area were the main factors affecting the accuracy of photogrammetric DEMs negatively. Technical improvements such as using an aerial platform and/or placing artificial targets could significantly improve the results but run the risk of being more demanding in terms of costs and logistics

    Off-Line Camera-Based Calibration for Optical See-Through Head-Mounted Displays

    Get PDF
    In recent years, the entry into the market of self contained optical see-through headsets with integrated multi-sensor capabilities has led the way to innovative and technology driven augmented reality applications and has encouraged the adoption of these devices also across highly challenging medical and industrial settings. Despite this, the display calibration process of consumer level systems is still sub-optimal, particularly for those applications that require high accuracy in the spatial alignment between computer generated elements and a real-world scene. State-of-the-art manual and automated calibration procedures designed to estimate all the projection parameters are too complex for real application cases outside laboratory environments. This paper describes an off-line fast calibration procedure that only requires a camera to observe a planar pattern displayed on the see-through display. The camera that replaces the user’s eye must be placed within the eye-motion-box of the see-through display. The method exploits standard camera calibration and computer vision techniques to estimate the projection parameters of the display model for a generic position of the camera. At execution time, the projection parameters can then be refined through a planar homography that encapsulates the shift and scaling effect associated with the estimated relative translation from the old camera position to the current user’s eye position. Compared to classical SPAAM techniques that still rely on the human element and to other camera based calibration procedures, the proposed technique is flexible and easy to replicate in both laboratory environments and real-world settings

    Optical See-Through Head-Mounted Displays With Short Focal Distance: Conditions for Mitigating Parallax-Related Registration Error

    Get PDF
    Optical see-through (OST) augmented reality head-mounted displays are quickly emerging as a key asset in several application fields but their ability to profitably assist high precision activities in the peripersonal space is still sub-optimal due to the calibration procedure required to properly model the user's viewpoint through the see-through display. In this work, we demonstrate the beneficial impact, on the parallax-related AR misregistration, of the use of optical see-through displays whose optical engines collimate the computer-generated image at a depth close to the fixation point of the user in the peripersonal space. To estimate the projection parameters of the OST display for a generic viewpoint position, our strategy relies on a dedicated parameterization of the virtual rendering camera based on a calibration routine that exploits photogrammetry techniques. We model the registration error due to the viewpoint shift and we validate it on an OST display with short focal distance. The results of the tests demonstrate that with our strategy the parallax-related registration error is submillimetric provided that the scene under observation stays within a suitable view volume that falls in a ±10 cm depth range around the focal plane of the display. This finding will pave the way to the development of new multi-focal models of OST HMDs specifically conceived to aid high-precision manual tasks in the peripersonal space

    Rocky Headwaters in the Dolomites, Italy: Field Observations and Topographic Analysis

    Get PDF
    • …
    corecore