517 research outputs found

    Radio Tests of GR

    Full text link
    Since VLBI techniques give microarcsecond position accuracy of celestial objects, tests of GR using radio sources as probes of a gravitational field have been made. We present the results from two recent tests using the VLBA: In 2005, the measurement of the classical solar deflection; and in 2002, the measurement of the retarded gravitational deflection associated with Jupiter. The deflection experiment measured PPN-gamma to an accuracy of 0.0003; the Jupiter experiment measured the retarded term to 20% accuracy. The controversy over the interpretation of the retarded term is summarized.Comment: 4 pages: IAU24

    From Reference Frames to Relativistic Experiments: Absolute and Relative Radio Astrometry

    Full text link
    Reference systems and frames are crucial for high precision absolute astrometric work, and their foundations must be well-defined. The current frame, the International Celestial Reference Frame, will be discussed: its history, the use of the group delay as the measured quantity, the positional accuracy of 0.3 milliarcsec, and possible future improvements. On the other hand, for the determination of the motion of celestial objects, accuracies approaching 0.01 milliarcsec can be obtained by measuring the differential position between the target object and nearby stationary sources. This astrometric technique uses phase referencing, and the current techniques and limitations are discussed, using the results from four experiments. Brief comments are included on the interpretation of the Jupiter gravity deflection experiment of September 2002.Comment: 25 pages, 7 figures--Presented at JENAM meeting in Budapest, 27-30 August 200

    Sub-Milliarcsecond Precision of Pulsar Motions: Using In-Beam Calibrators with the VLBA

    Full text link
    We present Very Long Baseline Array phase-referenced measurements of the parallax and proper motion of two pulsars, B0919+06 and B1857-26. Sub-milliarcsecond positional accuracy was obtained by simultaneously observing a weak calibrator source within the 40' field of view of the VLBA at 1.5 GHz. We discuss the merits of using weak close calibrator sources for VLBI observations at low frequencies, and outline a method of observation and data reduction for these type of measurements. For the pulsar B1919+06 we measure a parallax of 0.31 +/- 0.14 mas. The accuracy of the proper motions is approximately 0.5 mas, an order of magnitude improvement over most previous determinations.Comment: 11 pages plus 4 figures. In press, Astronomical Journa

    Progress in Measurements of the Gravitational Bending of Radio Waves Using the VLBA

    Get PDF
    We have used the Very Long Baseline Array (VLBA) at 43, 23 and 15 GHz to measure the solar gravitational deflection of radio waves among four radio sources during an 18-day period in October 2005. Using phase-referenced radio interferometry to fit the measured phase delay to the propagation equation of the parameterized post-Newtonian (PPN) formalism, we have determined the deflection parameter gamma = 0.9998 +/- 0.0003$ (68% confidence level), in agreement with General Relativity. The results come mainly from 43 GHz observations where the refraction effects of the solar corona were negligible beyond 3 degrees from the sun. The purpose of this experiment is three-fold: to improve on the previous results in the gravitational bending experiments near the solar limb; to examine and evaluate the accuracy limits of terrestrial VLBI techniques; and to determine the prospects and outcomes of future experiments. Our conclusion is that a series of improved designed experiments with the VLBA could increase the presented accuracy by at least a factor of 4.Comment: 22 pages, 3 figure

    ALMA Temporal Phase Stability and the Effectiveness of Water Vapor Radiometer

    Full text link
    Atacama Large Millimeter/submillimeter Array (ALMA) will be the world largest mm/submm interferometer, and currently the Early Science is ongoing, together with the commissioning and science verification (CSV). Here we present a study of the temporal phase stability of the entire ALMA system from antennas to the correlator. We verified the temporal phase stability of ALMA using data, taken during the last two years of CSV activities. The data consist of integrations on strong point sources (i.e., bright quasars) at various frequency bands, and at various baseline lengths (up to 600 m). From the observations of strong quasars for a long time (from a few tens of minutes, up to an hour), we derived the 2-point Allan Standard Deviation after the atmospheric phase correction using the 183 GHz Water Vapor Radiometer (WVR) installed in each 12 m antenna, and confirmed that the phase stability of all the baselines reached the ALMA specification. Since we applied the WVR phase correction to all the data mentioned above, we also studied the effectiveness of the WVR phase correction at various frequencies, baseline lengths, and weather conditions. The phase stability often improves a factor of 2 - 3 after the correction, and sometimes a factor of 7 improvement can be obtained. However, the corrected data still displays an increasing phase fluctuation as a function of baseline length, suggesting that the dry component (e.g., N2 and O2) in the atmosphere also contributes the phase fluctuation in the data, although the imperfection of the WVR phase correction cannot be ruled out at this moment.Comment: Proc. SPIE 8444-125, in press (7 pages, 4 figures, 1 table
    • …
    corecore