57 research outputs found

    Machine learning in intensive care medicine: ready for take-off?

    Get PDF
    In 1986 the world was shaken by the Challenger space shuttle disaster. In the years that followed, the American National Aeronautics and Space Administration (NASA) called for a strategy change in space technology development [1]. Allowing technology to be developed without a specific space program in mind was central to the new strategy [2]. In order to evaluate resulting projects with no direct contribution to a space mission, NASA introduced the general concept of technology readiness levels (TRLs) [3]. These nine levels, adopted by many EU institutions, assess the maturity level of technology and estimate its readiness to fly

    Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy

    Get PDF
    Abstract: Purpose: Early clinical recognition of sepsis can be challenging. With the advancement of machine learning, promising real-time models to predict sepsis have emerged. We assessed their performance by carrying out a systematic review and meta-analysis. Methods: A systematic search was performed in PubMed, Embase.com and Scopus. Studies targeting sepsis, severe sepsis or septic shock in any hospital setting were eligible for inclusion. The index test was any supervised machine learning model for real-time prediction of these conditions. Quality of evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology, with a tailored Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist to evaluate risk of bias. Models with a reported area under the curve of the receiver operating characteristic (AUROC) metric were meta-analyzed to identify strongest contributors to model performance. Results: After screening, a total of 28 papers were eligible for synthesis, from which 130 models were extracted. The majority of papers were developed in the intensive care unit (ICU, n = 15; 54%), followed by hospital wards (n = 7; 25%), the emergency department (ED, n = 4; 14%) and all of these settings (n = 2; 7%). For the prediction of sepsis, diagnostic test accuracy assessed by the AUROC ranged from 0.68–0.99 in the ICU, to 0.96–0.98 in-hospital and 0.87 to 0.97 in the ED. Varying sepsis definitions limit pooling of the performance across studies. Only three papers clinically implemented models with mixed results. In the multivariate analysis, temperature, lab values, and model type contributed most to model performance. Conclusion: This systematic review and meta-analysis show that on retrospective data, individual machine learning models can accurately predict sepsis onset ahead of time. Although they present alternatives to traditional scoring systems, between-study heterogeneity limits the assessment of pooled results. Systematic reporting and clinical implementation studies are needed to bridge the gap between bytes and bedside

    Ascitic complement system in ovarian cancer

    Get PDF
    Ovarian cancer spreads intraperitoneally and forms fluid, whereby the diagnosis and therapy often become delayed. As the complement (C) system may provide a cytotoxic effector arm for both immunological surveillance and mAb-therapy, we have characterised the C system in the intraperitoneal ascitic fluid (AF) from ovarian cancer patients. Most of the AF samples showed alternative and classical pathway haemolytic activity. The levels of C3 and C4 were similar to or in the lower normal range when compared to values in normal sera, respectively. However, elevated levels of C3a and soluble C5b-9 suggested C activation in vivo. Malignant cells isolated from the AF samples had surface deposits of C1q and C3 activation products, but not of C5b-9 (the membrane attack complex; MAC). Activation could have become initiated by anti-tumour cell antibodies that were detected in the AFs and/or by changes on tumour cell surfaces. The lack of MAC was probably due to the expression of C membrane regulators CD46, CD55 and CD59 on the tumour cells. Soluble forms of C1 inhibitor, CD59 and CD46, and the alternative pathway inhibitors factor H and FHL-1 were present in the AF at concentrations higher than in serum samples. Despite the presence of soluble C inhibitors it was possible to use AF as a C source in antibody-initiated killing of ovarian carcinoma cells. These results demonstrate that although the ovarian ascitic C system fails as an effective immunological surveillance mechanism, it could be utilised as an effector mechanism in therapy with intraperitoneally administrated mAbs, especially if the intrinsic C regulators are neutralised

    Autoantibodies against type I IFNs in patients with life-threatening COVID-19

    Get PDF
    Interindividual clinical variability in the course of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is vast. We report that at least 101 of 987 patients with life-threatening coronavirus disease 2019 (COVID-19) pneumonia had neutralizing immunoglobulin G (IgG) autoantibodies (auto-Abs) against interferon-w (IFN-w) (13 patients), against the 13 types of IFN-a (36), or against both (52) at the onset of critical disease; a few also had auto-Abs against the other three type I IFNs. The auto-Abs neutralize the ability of the corresponding type I IFNs to block SARS-CoV-2 infection in vitro. These auto-Abs were not found in 663 individuals with asymptomatic or mild SARS-CoV-2 infection and were present in only 4 of 1227 healthy individuals. Patients with auto-Abs were aged 25 to 87 years and 95 of the 101 were men. A B cell autoimmune phenocopy of inborn errors of type I IFN immunity accounts for life-threatening COVID-19 pneumonia in at least 2.6% of women and 12.5% of men

    Large-scale ICU data sharing for global collaboration: the first 1633 critically ill COVID-19 patients in the Dutch Data Warehouse

    Get PDF

    Why physiology will continue to guide the choice between balanced crystalloids and normal saline: a systematic review and meta-analysis

    No full text
    BACKGROUND: Crystalloids are the most frequently prescribed drugs in intensive care medicine and emergency medicine. Thus, even small differences in outcome may have major implications, and therefore, the choice between balanced crystalloids versus normal saline continues to be debated. We examined to what extent the currently accrued information size from completed and ongoing trials on the subject allow intensivists and emergency physicians to choose the right fluid for their patients. METHODS: Systematic review and meta-analysis with random effects inverse variance model. Published randomized controlled trials enrolling adult patients to compare balanced crystalloids versus normal saline in the setting of intensive care medicine or emergency medicine were included. The main outcome was mortality at the longest follow-up, and secondary outcomes were moderate to severe acute kidney injury (AKI) and initiation of renal replacement therapy (RRT). Trial sequential analyses (TSA) were performed, and risk of bias and overall quality of evidence were assessed. Additionally, previously published meta-analyses, trial sequential analyses and ongoing large trials were analysed for included studies, required information size calculations and the assumptions underlying those calculations. RESULTS: Nine studies (n = 32,777) were included. Of those, eight had data available on mortality, seven on AKI and six on RRT. Meta-analysis showed no significant differences between balanced crystalloids versus normal saline for mortality (P = 0.33), the incidence of moderate to severe AKI (P = 0.37) or initiation of RRT (P = 0.29). Quality of evidence was low to very low. Analysis of previous meta-analyses and ongoing trials showed large differences in calculated required versus accrued information sizes and assumptions underlying those. TSA revealed the need for extremely large trials based on our realistic and clinically relevant assumptions on relative risk reduction and baseline mortality. CONCLUSIONS: Our meta-analysis could not find significant differences between balanced crystalloids and normal saline on mortality at the longest follow-up, moderate to severe AKI or new RRT. Currently accrued information size is smaller, and the required information size is larger than previously anticipated. Therefore, completed and ongoing trials on the topic may fail to provide adequate guidance for choosing the right crystalloid. Thus, physiology will continue to play an important role for individualizing this choice

    Right Dose, Right Now: Development of AutoKinetics for Real Time Model Informed Precision Antibiotic Dosing Decision Support at the Bedside of Critically Ill Patients

    No full text
    Introduction: Antibiotic dosing in critically ill patients is challenging because their pharmacokinetics (PK) are altered and may change rapidly with disease progression. Standard dosing frequently leads to inadequate PK exposure. Therapeutic drug monitoring (TDM) offers a potential solution but requires sampling and PK knowledge, which delays decision support. It is our philosophy that antibiotic dosing support should be directly available at the bedside through deep integration into the electronic health record (EHR) system. Therefore we developed AutoKinetics, a clinical decision support system (CDSS) for real time, model informed precision antibiotic dosing. Objective: To provide a detailed description of the design, development, validation, testing, and implementation of AutoKinetics. Methods: We created a development framework and used workflow analysis to facilitate integration into popular EHR systems. We used a development cycle to iteratively adjust and expand AutoKinetics functionalities. Furthermore, we performed a literature review to select and integrate pharmacokinetic models for five frequently prescribed antibiotics for sepsis. Finally, we tackled regulatory challenges, in particular those related to the Medical Device Regulation under the European regulatory framework. Results: We developed a SQL-based relational database as the backend of AutoKinetics. We developed a data loader to retrieve data in real time. We designed a clinical dosing algorithm to find a dose regimen to maintain antibiotic pharmacokinetic exposure within clinically relevant safety constraints. If needed, a loading dose is calculated to minimize the time until steady state is achieved. Finally, adaptive dosing using Bayesian estimation is applied if plasma levels are available. We implemented support for five extensively used antibiotics following model development, calibration, and validation. We integrated AutoKinetics into two popular EHRs (Metavision, Epic) and developed a user interface that provides textual and visual feedback to the physician. Conclusion: We successfully developed a CDSS for real time model informed precision antibiotic dosing at the bedside of the critically ill. This holds great promise for improving sepsis outcome. Therefore, we recently started the Right Dose Right Now multi-center randomized control trial to validate this concept in 420 patients with severe sepsis and septic shock
    corecore