13,751 research outputs found

    Nonequilibrium Dynamics of Charged Particles in an Electromagnetic Field: Causal and Stable Dynamics from 1/c Expansion of QED

    Full text link
    We derive from a microscopic Hamiltonian a set of stochastic equations of motion for a system of spinless charged particles in an electromagnetic (EM) field based on a consistent application of a dimensionful 1/c expansion of quantum electrodynamics (QED). All relativistic corrections up to order 1/c^3 are captured by the dynamics, which includes electrostatic interactions (Coulomb), magnetostatic backreaction (Biot-Savart), dissipative backreaction (Abraham-Lorentz) and quantum field fluctuations at zero and finite temperatures. With self-consistent backreaction of the EM field included we show that this approach yields causal and runaway-free equations of motion, provides new insights into charged particle backreaction, and naturally leads to equations consistent with the (classical) Darwin Hamiltonian and has quantum operator ordering consistent with the Breit Hamiltonian. To order 1/c^3 the approach leads to a nonstandard mass renormalization which is associated with magnetostatic self-interactions, and no cutoff is required to prevent runaways. Our new results also show that the pathologies of the standard Abraham-Lorentz equations can be seen as a consequence of applying an inconsistent (i.e. incomplete, mixed-order) expansion in 1/c, if, from the start, the analysis is viewed as generating a low-energy effective theory rather than an exact solution. Finally, we show that the 1/c expansion within a Hamiltonian framework yields well-behaved noise and dissipation, in addition to the multiple-particle interactions.Comment: 17 pages, 2 figure

    Unimolecular reaction rates in solution and in the isolated molecule: Comparison of diphenyl butadiene nonradiative decay in solutions and supersonic jets

    Get PDF
    The recent study of diphenyl butadiene (DPB) in supersonic jets and in solution by Shepanski et al.(1) and by Courtney and Felming(2), respectively, provides an opportunity to compare the isomerization rates measured in the isolated molecule (jet) with those measured at very low viscosity in solution. These comparisons should shed light on the vibrational energy flows between “optical” and “reactive” modes in the isolated molecule and on the connection between activated, friction dependent, models of barrier crossing in solution,(3-5) and statistical RRK (or RRKM) theories of gas phase unimolecular reactions(6)

    The solar dynamic radiator with a historical perspective

    Get PDF
    A historical perspective on pumped-fluid loop space radiators provides a basis for the design of the Space Station Solar Dynamic (SD) power module radiator. SD power modules, capable of generating 25 kW (electrical) each, are planned for growth in Station power requirements. The Brayton cycle SD module configuration incorporates a pumped-fluid loop radiator that must reject up to 99 kW (thermal). The thermal/hydraulic design conditions in combination with required radiator orientation and packaging envelope form a unique set of constraints as compared to previous pumped-fluid loop radiator systems. Nevertheless, past program successes have demonstrated a technology base that can be applied to the SD radiator development program to ensure a low risk, low cost system

    The Organic Research Centre - Elm Farm:Bulletin 87

    Get PDF
    Bulletin 87 with coverage of Avian Influenza H5N1 in Suffolk,commentary on Biofuels, a paper on the organic "transition to sustainable resilience",paper on participatory approach to agronomy trials,update on evolutionary breeding of wheat project,article on formation of new growers alliance in UK

    Non-Markovian Dynamics and Entanglement of Two-level Atoms in a Common Field

    Full text link
    We derive the stochastic equations and consider the non-Markovian dynamics of a system of multiple two-level atoms in a common quantum field. We make only the dipole approximation for the atoms and assume weak atom-field interactions. From these assumptions we use a combination of non-secular open- and closed-system perturbation theory, and we abstain from any additional approximation schemes. These more accurate solutions are necessary to explore several regimes: in particular, near-resonance dynamics and low-temperature behavior. In detuned atomic systems, small variations in the system energy levels engender timescales which, in general, cannot be safely ignored, as would be the case in the rotating-wave approximation (RWA). More problematic are the second-order solutions, which, as has been recently pointed out, cannot be accurately calculated using any second-order perturbative master equation, whether RWA, Born-Markov, Redfield, etc.. This latter problem, which applies to all perturbative open-system master equations, has a profound effect upon calculation of entanglement at low temperatures. We find that even at zero temperature all initial states will undergo finite-time disentanglement (sometimes termed "sudden death"), in contrast to previous work. We also use our solution, without invoking RWA, to characterize the necessary conditions for Dickie subradiance at finite temperature. We find that the subradiant states fall into two categories at finite temperature: one that is temperature independent and one that acquires temperature dependence. With the RWA there is no temperature dependence in any case.Comment: 17 pages, 13 figures, v2 updated references, v3 clarified results and corrected renormalization, v4 further clarified results and new Fig. 8-1

    The Organic Research Centre; Elm Farm Bulletin 84 July 2006

    Get PDF
    Regular bulletin with technical updates of the Organic Advisory Service Issue contains: Battling on for Avian Flu preventive vaccination; Organic Colombian Blacktail eggs; UK Co-existence - GMOand non-GMO crops; Aspects of Poultry Behaviour; CAP in the service of biodiversity; Seeing the Wood, the Trees and the Catch 22; Beware of organic market "statistics"; A central role in energy review

    Improving the clinical value and utility of CGM systems: issues and recommendations : a joint statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group

    Get PDF
    The first systems for continuous glucose monitoring (CGM) became available over 15 years ago. Many then believed CGM would revolutionise the use of intensive insulin therapy in diabetes; however, progress towards that vision has been gradual. Although increasing, the proportion of individuals using CGM rather than conventional systems for self-monitoring of blood glucose on a daily basis is still low in most parts of the world. Barriers to uptake include cost, measurement reliability (particularly with earlier-generation systems), human factors issues, lack of a standardised format for displaying results and uncertainty on how best to use CGM data to make therapeutic decisions. This scientific statement makes recommendations for systemic improvements in clinical use and regulatory (pre- and postmarketing) handling of CGM devices. The aim is to improve safety and efficacy in order to support the advancement of the technology in achieving its potential to improve quality of life and health outcomes for more people with diabetes

    Improving the clinical value and utility of CGM systems: issues and recommendations: a joint statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group

    Get PDF
    The first systems for continuous glucose monitoring (CGM) became available over 15 years ago. Many then believed CGM would revolutionize the use of intensive insulin therapy in diabetes; however, progress toward that vision has been gradual. Although increasing, the proportion of individuals using CGM rather than conventional systems for self-monitoring of blood glucose on a daily basis is still low in most parts of the world. Barriers to uptake include cost, measurement reliability (particularly with earlier-generation systems), human factors issues, lack of a standardized format for displaying results, and uncertainty on how best to use CGM data to make therapeutic decisions. This Scientific Statement makes recommendations for systemic improvements in clinical use and regulatory (pre- and postmarketing) handling of CGM devices. The aim is to improve safety and efficacy in order to support the advancement of the technology in achieving its potential to improve quality of life and health outcomes for more people with diabetes
    corecore