1,451 research outputs found
The mechanical and electrical properties of direct-spun carbon nanotube mat-epoxy composites
Composites of direct-spun carbon nanotube (CNT) mats and epoxy are
manufactured and tested in order to determine their mechanical and electrical
properties. The mats are spun directly from a floating catalyst, chemical
vapour deposition reactor. The volume fraction of epoxy is varied widely by
suitable dilution of the epoxy resin with acetone. Subsequent evaporation of
the acetone, followed by a cure cycle, leads to composites of varying volume
fraction of CNT, epoxy and air. The modulus, strength, electrical conductivity
and piezoresistivity of the composites are measured. The CNT mats and their
composites exhibit an elastic-plastic stress-strain response under uniaxial
tensile loading, and the degree of anisotropy is assessed by testing specimens
in 0{\deg}, 45{\deg} and 90{\deg} directions with respect to the draw direction
of mat manufacture. The electrical conductivity scales linearly with CNT volume
fraction, irrespective of epoxy volume fraction. In contrast, the modulus and
strength depend upon both CNT and epoxy volume fractions in a non-linear
manner. The macroscopic moduli of the CNT mat-epoxy composites are far below
the Voigt bound based on the modulus of CNT walls and epoxy. A micromechanical
model is proposed to relate the macroscopic modulus and yield strength of a CNT
mat-epoxy composite to the microstructure
The mechanical and electrical properties of direct-spun carbon nanotube mats
The mechanical and electrical properties of a direct-spun carbon nanotube mat are measured. The mat comprises an interlinked random network of nanotube bundles, with approximately 40 nanotubes in a bundle. A small degree of in-plane anisotropy is observed. The bundles occasionally branch, and the mesh topology resembles a 2D lattice of nodal connectivity slightly below 4. The macroscopic in-plane tensile response is elasto-plastic in nature, with significant orientation hardening. In-situ microscopy reveals that the nanotube bundles do not slide past each other at their junctions under macroscopic stain. A micromechanical model is developed to relate the macroscopic modulus and flow strength to the longitudinal shear response of the nanotube bundles. The mechanical and electrical properties of the mat are compared with those of other nanotube arrangements over a wide range of density
The epidemiology of injuries across the weight-training sports
Background: Weight-training sports, including weightlifting, powerlifting, bodybuilding, strongman, Highland Games, and CrossFit, are weight-training sports that have separate divisions for males and females of a variety of ages, competitive standards, and bodyweight classes. These sports may be considered dangerous because of the heavy loads commonly used in training and competition. Objectives: Our objective was to systematically review the injury epidemiology of these weight-training sports, and, where possible, gain some insight into whether this may be affected by age, sex, competitive standard, and bodyweight class. Methods: We performed an electronic search using PubMed, SPORTDiscus, CINAHL, and Embase for injury epidemiology studies involving competitive athletes in these weight-training sports. Eligible studies included peer-reviewed journal articles only, with no limit placed on date or language of publication. We assessed the risk of bias in all studies using an adaption of the musculoskeletal injury review method. Results: Only five of the 20 eligible studies had a risk of bias score â„75 %, meaning the risk of bias in these five studies was considered low. While 14 of the studies had sample sizes >100 participants, only four studies utilized a prospective design. Bodybuilding had the lowest injury rates (0.12â0.7 injuries per lifter per year; 0.24â1 injury per 1000 h), with strongman (4.5â6.1 injuries per 1000 h) and Highland Games (7.5 injuries per 1000 h) reporting the highest rates. The shoulder, lower back, knee, elbow, and wrist/hand were generally the most commonly injured anatomical locations; strains, tendinitis, and sprains were the most common injury type. Very few significant differences in any of the injury outcomes were observed as a function of age, sex, competitive standard, or bodyweight class. Conclusion: While the majority of the research we reviewed utilized retrospective designs, the weight-training sports appear to have relatively low rates of injury compared with common team sports. Future weight-training sport injury epidemiology research needs to be improved, particularly in terms of the use of prospective designs, diagnosis of injury, and changes in risk exposure
Measurement of the charm structure function F_{2,c)^{Îł} of the photon at LEP
The production of charm quarks is studied in deep-inelastic electronâphoton scattering using data recorded by the OPAL detector at LEP at nominal eâșeâ» centre-of-mass energies from 183 to 209 GeV. The charm quarks have been identified by full reconstruction of charged D* mesons using their decays into Dâ°Ï with the Dâ° observed in two decay modes with charged particle final states, KÏ and KÏÏÏ. The cross-section Ï^{D*} for production of charged D* in the reaction eâșeâ»âeâșeâ»D*Χ is measured in a restricted kinematical region using two bins in Bjorken x, 0.00140.1 the perturbative QCD calculation at next-to-leading order agrees perfectly with the measured cross-section. For x<0.1 the measured cross-section is 43.8±14.3±6.3±2.8 pb with a next-to-leading order prediction of 17.0âșÂČ·âč_â.â pb
No hypoperfusion is produced in the epicardium during application of myocardial topical negative pressure in a porcine model
ABSTRACT: BACKGROUND: Topical negative pressure (TNP), commonly used in wound therapy, has been shown to increase blood flow and stimulate angiogenesis in skeletal muscle. We have previously shown that a myocardial TNP of -50 mmHg significantly increases microvascular blood flow in the myocardium. When TPN is used in wound therapy (on skeletal and subcutaneous tissue) a zone of relative hypoperfusion is seen close to the wound edge. Hypoperfusion induced by TNP is thought to depend on tissue density, distance from the negative pressure source, and the amount negative pressure applied. When applying TNP to the myocardium, a significant, long-standing zone of hypoperfusion could theoretically cause ischemia, and negative effects on the myocardium. The current study was designed to elucidate whether hypoperfusion was produced during myocardial TNP. METHODS: Six pigs underwent median sternotomy. Laser Doppler probes were inserted horizontally into the heart muscle in the LAD area, at depths of approximately, 1-2 mm. The microvascular blood flow was measured before and after the application of a TNP. Analyses were performed before left anterior descending artery (LAD) occlusion (normal myocardium) and after 20 minutes of LAD occlusion (ischemic myocardium). RESULTS: A TNP of -50 mmHg induced a significant increase in microvascular blood flow in normal myocardium (**p = 0.01), while -125 mmHg did not significantly alter the microvascular blood flow. In ischemic myocardium a TNP of -50 mmHg induced a significant increase in microvascular blood flow (*p = 0.04), while -125 mmHg did not significantly alter the microvascular blood flow. CONCLUSION: No hypoperfusion could be observed in the epicardium in neither normal nor ischemic myocardium during myocardial TNP
Measurement of the running of the QED coupling in small-angle Bhabha scattering at LEP
Using the OPAL detector at LEP, the running of the effective QED coupling
alpha(t) is measured for space-like momentum transfer from the angular
distribution of small-angle Bhabha scattering. In an almost ideal QED
framework, with very favourable experimental conditions, we obtain:
Delta alpha(-6.07GeV^2) - Delta alpha(-1.81GeV^2) = (440 pm 58 pm 43 pm 30) X
10^-5, where the first error is statistical, the second is the experimental
systematic and the third is the theoretical uncertainty. This agrees with
current evaluations of alpha(t).The null hypothesis that alpha remains constant
within the above interval of -t is excluded with a significance above 5sigma.
Similarly, our results are inconsistent at the level of 3sigma with the
hypothesis that only leptonic loops contribute to the running. This is
currently the most significant direct measurment where the running alpha(t) is
probed differentially within the measured t range.Comment: 43 pages, 12 figures, Submitted to Euro. Phys. J.
Complex, but not quite complex enough : The turn to the complexity sciences in evaluation scholarship
This document is the Accepted Manuscript version of the following article: Chris Mowles, âComplex, but not quite complex enough: The turn to the complexity sciences in evaluation scholarshipâ. The final, definitive version of this paper has been published in Evaluation, Vol. 20 (2): 160-175, April 2014, doi: https://doi.org/10.1177/1356389014527885 , published by SAGE Publishing. All rights reserved.This article offers a critical review of the way in which some scholars have taken up the complexity sciences in evaluation scholarship. I argue that there is a tendency either to over-claim or under-claim their importance because scholars are not always careful about which of the manifestations of the complexity sciences they are appealing to, nor do they demonstrate how they understand them in social terms. The effect is to render âcomplexityâ just another volitional tool in the evaluatorâs toolbox subsumed under the dominant understanding of evaluation, as a logical, rational activity based on systems thinking and design. As an alternative I argue for a radical interpretation of the complexity sciences, which understands human interaction as always complex and emergent. The interweaving of intentions in human activity will always bring about outcomes that no one has intended including in the activity of evaluation itself.Peer reviewe
- âŠ