97 research outputs found
440 Assessing cardiac output by echocardiography: is contrast always better?
Abstract
Aims
Contrast echocardiography is very useful in clinical cardiology. It is mainly performed for the assessment of global left ventricular (LV) function, left ventricular ejection fraction (LVEF), and stroke volume (SV), thanks to improved visualization of endocardial LV borders. Contrast echocardiography, however, is not always easily available, it is more expensive than an ordinary echocardiography and it can be contraindicated in some situations (e.g. in the presence of egg allergy). This study aimed to compare the estimation of cardiac output during traditional transthoracic echocardiography and after the injection of (Sonovue) contrast.
Methods and results
Patients who underwent an echocardiography with and without injection of (Sonovue) contrast between April 2019 and September 2021 were enrolled in the study. A complete transthoracic echocardiography was performed and Sonovue contrast was then injected. End-diastolic and end-systolic left ventricular volume in apex 4 and 2 chamber views, biplane LVEF with Simpson's formula, end-diastolic and end-systolic left ventricular diameters in parasternal long axis were measured prior and after injecting contrast. Left ventricular outflow tract diameter (LVOTd) was measured and LV outflow tract velocity time integral was traced in order to calculate LVOT VTI SV, as the product of LVOT cross sectional area (assuming that LVOT is circular) to the LVOT VTI. LVOT VTI SV obtained during traditional echocardiography was compared to LVEF SV, calculated as the difference between end-diastolic and end-systolic volume traced after injecting Sonovue contrast. Seventy-eight patients were enrolled in the study. Forty-two had history of CAD, 22 presented dilatative cardiomyopathy, 2 hypertrophic cardiomyopathy (HMC), 1 arrhythmogenic right ventricular dysplasia; 16 had atrial fibrillation, 66 arterial hypertension, and 20 diabetes. The main indications for contrast echocardiography were measurement of EF (39 cases) and exclusion of thrombi in LV apex (18 cases). Other indications were suspect of HCM, atrial myxoma or LV non-compaction. LVOT VTI stroke volume was calculated in 64 patients (LVOT diameter was not well visualized in 8 patients and LVOT VTI could not be measured in 14 patients due to poor acoustic windows). In the same patients LVEF Stroke Volume was also calculated. A strong correlation (P-value < 0.0001) between LVOT stroke volume and LVEF Stroke Volume was found (Figure 1).
Conclusions
Contrast echocardiography is very useful in clinical practice, however, requires trained physicians and its use is not widespread. This study demonstrates that estimating cardiac output through LVOT VTI SV, in patients with suboptimal echo images can be equally accurate as measuring LVEF SV with contrast echocardiography. This could be particularly useful in the acute settings when contrast echocardiography isn't always feasible and knowing cardiac output can be important for therapeutic implications
Proof of concept study on coronary microvascular function in low flow low gradient aortic stenosis
ObjectivesWe hypothesised that low flow low gradient aortic stenosis (LFLGAS) is associated with more severe coronary microvascular dysfunction (CMD) compared with normal-flow high-gradient aortic stenosis (NFHGAS) and that CMD is related to reduced cardiac performance. MethodsInvasive CMD assessment was performed in 41 consecutive patients with isolated severe aortic stenosis with unobstructed coronary arteries undergoing transcatheter aortic valve implantation (TAVI). The index of microcirculatory resistance (IMR), resistive reserve ratio (RRR) and coronary flow reserve (CFR) were measured in the left anterior descending artery before and after TAVI. Speckle tracking echocardiography was performed to assess cardiac function at baseline and repeated at 6 months. ResultsIMR was significantly higher in patients with LFLGAS compared with patients with NFHGAS (24.1 (14.6 to 39.1) vs 12.8 (8.6 to 19.2), p=0.002), while RRR was significantly lower (1.4 (1.1 to 2.1) vs 2.6 (1.5 to 3.3), p=0.020). No significant differences were observed in CFR between the two groups. High IMR was associated with low stroke volume index, low cardiac output and reduced peak atrial longitudinal strain (PALS). TAVI determined no significant variation in microvascular function (IMR: 16.0 (10.4 to 26.1) vs 16.6 (10.2 to 25.6), p=0.403) and in PALS (15.9 (9.9 to 26.5) vs 20.1 (12.3 to 26.7), p=0.222). Conversely, left ventricular (LV) global longitudinal strain increased after TAVI (-13.2 (8.4 to 16.6) vs -15.1 (9.4 to 17.8), p=0.047). In LFLGAS, LV systolic function recovered after TAVI in patients with preserved microvascular function but not in patients with CMD. ConclusionsCMD is more severe in patients with LFLGAS compared with NFHGAS and is associated with low-flow state, left atrial dysfunction and reduced cardiac performance
Intracoronary physiology-guided percutaneous coronary intervention in patients with diabetes
Objective: The risk of vessel-oriented cardiac adverse events (VOCE) in patients with diabetes mellitus (DM) undergoing intracoronary physiology-guided coronary revascularization is poorly defined. The purpose of this work is to evaluate the risk of VOCE in patients with and without DM in whom percutaneous coronary intervention (PCI) was performed or deferred based on pressure-wire functional assessment. Methods: This is a retrospective analysis of a multicenter registry of patients evaluated with fractional flow reserve (FFR) and/or non-hyperaemic pressure ratio (NHPR). Primary endpoint was a composite of VOCE including cardiac death, vessel-related myocardial infarction (MI), and ischemia-driven target vessel revascularization (TVR). Results: A large cohort of 2828 patients with 3353 coronary lesions was analysed to assess the risk of VOCE at long-term follow-up (23 [14-36] months). Non-insulin-dependent-DM (NIDDM) was not associated with the primary endpoint in the overall cohort (adjusted Hazard Ratio [aHR] 1.18, 95% CI 0.87-1.59, P = 0.276) or in patients with coronary lesions treated with PCI (aHR = 1.30, 95% CI 0.78-2.16, P = 0.314). Conversely, insulin-dependent diabetes mellitus (IDDM) demonstrated an increased risk of VOCE in the overall cohort (aHR 1.76, 95% CI 1.07-2.91, P = 0.027), but not in coronary lesions undergoing PCI (aHR 1.26, 95% CI 0.50-3.16, P = 0.621). Importantly, in coronary lesions deferred after functional assessment IDDM (aHR 2.77, 95% CI 1.11-6.93, P = 0.029) but not NIDDM (aHR = 0.94, 95% CI 0.61-1.44, P = 0.776) was significantly associated with the risk of VOCE. IDDM caused a significant effect modification of FFR-based risk stratification (P for interaction < 0.001). Conclusion: Overall, DM was not associated with an increased risk of VOCE in patients undergoing physiology-guided coronary revascularization. However, IDDM represents a phenotype at high risk of VOCE
Clinical outcomes of transcatheter aortic valve implantation: from learning curve to proficiency
Objective: The use of transcatheter aortic valve implantation (TAVI) is growing rapidly in countries with a predominantly elderly population, posing a huge challenge to healthcare systems worldwide. The increment of human and economic resource consumption imposes a careful monitoring of clinical outcomes and cost-benefit balance, and this article is aimed at analysing clinical outcomes related to the TAVI learning curve.Methods: Outcomes of 177 consecutive transfemoral TAVI procedures performed in 5 years by a single team were analysed by the Cumulative Sum of failures method (CUSUM) according to the clinical events comprised in the Valve Academic Research Consortium (VARC-2) safety end point and the VARC-2 definition of device success. Margins for events acceptance were extrapolated from landmark trials that tested both balloon or self-expandable percutaneous valves.Results: 30-day and 1-year survival rates were 97.2% and 89.9%, respectively. Achievement of the primary end point (number of cases needed to provide the acceptable margin of the composite end point of any death, stroke, myocardial infarction, life-threatening bleeding, major vascular complications, stage 2-3 acute kidney injury and valve-related dysfunction requiring a repeat procedure) required the performance of 54 cases, while the learning curve to achieve 'device success' identified 32 cases to reach the expected proficiency. In this experience, the baseline clinical risk as assessed by the Society of Thoracic Surgeons (STS) score determined the long-term survival rather than the adverse events related to the learning curve.Conclusions: A relatively large number of cases are required to achieve clinical outcomes comparable to those reported in high-volume centres and controlled trials. According to our national workload standards, this represents more than 2 years of continuous activity
Accuracy of Micro-Computed Tomography in Post-mortem Evaluation of Fetal Congenital Heart Disease. Comparison Between Post-mortem Micro-CT and Conventional Autopsy.
Aims: Early prenatal diagnosis of congenital heart disease is feasible. Conventional autopsy is the current gold standard method for post-mortem confirmation. Radiologic techniques alternative to conventional autopsy, such as post-mortem micro-computed tomography, have been proposed in case of limited diagnostic accuracy (i.e., early termination of pregnancy, samples of small dimension or of low weight). The aim of the present study was to define accuracy of micro-computed tomography for post-mortem diagnosis of congenital heart disease in gross anatomy samples.Methods and Results: Fetal heart underwent in-utero prenatal echocardiography and ex-vivo post-mortem evaluation by 9 μm resolution micro-computed tomography and conventional autopsy. For each case, 25 indices of cardiac anatomy were studied by post-mortem micro-computed tomography and conventional autopsy; these were used to compare the two post mortem techniques. Ten samples were examined (gestational age between 12 + 4 and 21 + 6 weeks of gestation). Considering comparable indices, agreement between post-mortem micro-computed tomography and conventional autopsy was of 100% and sensitivity and specificity were of 100%. In “challenging specimens,” post-mortem micro-computed tomography diagnoses more indices as compared to conventional autopsy and 84% of “not-diagnostic” indices at conventional autopsy would be diagnostic at post-mortem micro-computed tomography.Conclusion: Micro-computed tomography can be a valid diagnostic alternative to conventional autopsy for post-mortem evaluation of human fetal heart. In addition, it may prove superior to conventional autopsy particularly in cases coming from early termination of pregnancy or in samples of small dimension or of low weight
Characterization and Management of Stable Coronary Artery Disease in Patients Undergoing Transcatheter Aortic Valve Implantation.
Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively
Impact of COVID-19 Pandemic on TAVR Activity: A Worldwide Registry
Background: The COVID-19 pandemic had a considerable impact on the provision of structural heart intervention worldwide. Our objectives were: 1) to assess the impact of the COVID-19 pandemic on transcatheter aortic valve replacement (TAVR) activity globally; and 2) to determine the differences in the impact according to geographic region and the demographic, development, and economic status of diverse international health care systems.
Methods: We developed a multinational registry of global TAVR activity and invited individual TAVR sites to submit TAVR implant data before and during the COVID-19 pandemic. Specifically, the number of TAVR procedures performed monthly from January 2019 to December 2021 was collected. The adaptive measures to maintain TAVR activity by each site were recorded, as was a variety of indices relating to type of health care system and national economic indices. The primary subject of interest was the impact on TAVR activity during each of the pandemic waves (2020 and 2021) compared with the same period pre–COVID-19 (2019).
Results: Data were received from 130 centers from 61 countries, with 14 subcontinents and 5 continents participating in the study. Overall, TAVR activity increased by 16.7% (2,337 procedures) between 2018 and 2019 (ie, before the pandemic), but between 2019 and 2020 (ie, first year of the pandemic), there was no significant growth (–0.1%; –10 procedures). In contrast, activity again increased by 18.9% (3,085 procedures) between 2020 and 2021 (ie, second year of the pandemic). During the first pandemic wave, there was a reduction of 18.9% (945 procedures) in TAVR activity among participating sites, while during the second and third waves, there was an increase of 6.7% (489 procedures) and 15.9% (1,042 procedures), respectively. Further analysis and results of this study are ongoing and will be available at the time of the congress.
Conclusion: The COVID-19 pandemic initially led to a reduction in the number of patients undergoing TAVR worldwide, although health care systems subsequently adapted, and the number of TAVR recipients continued to grow in subsequent COVID-19 pandemic waves.
Categories: STRUCTURAL: Valvular Disease: Aorti
Cardiopoietic cell therapy for advanced ischemic heart failure: results at 39 weeks of the prospective, randomized, double blind, sham-controlled CHART-1 clinical trial
Cardiopoietic cells, produced through cardiogenic conditioning of patients' mesenchymal stem cells, have shown preliminary efficacy. The Congestive Heart Failure Cardiopoietic Regenerative Therapy (CHART-1) trial aimed to validate cardiopoiesis-based biotherapy in a larger heart failure cohort
Rationale for the use of bioresorbable vascular scaffolds. Why bioresorbable technology is the future of endovascular therapeutics
Ancora in fase di pubblicazi
Irradiación beta intracoronaria para la prevención de la restenosis intra-stent en pacientes con perfil genético de alto riesgo endoproliferativo
Premios: Ayudas a la Investidación Ignacio Larramendi, 1998-199
- …