11,065 research outputs found

    Research investigation of helicopter main rotor/tail rotor interaction noise

    Get PDF
    Acoustic measurements were obtained in a Langley 14 x 22 foot Subsonic Wind Tunnel to study the aeroacoustic interaction of 1/5th scale main rotor, tail rotor, and fuselage models. An extensive aeroacoustic data base was acquired for main rotor, tail rotor, fuselage aerodynamic interaction for moderate forward speed flight conditions. The details of the rotor models, experimental design and procedure, aerodynamic and acoustic data acquisition and reduction are presented. The model was initially operated in trim for selected fuselage angle of attack, main rotor tip-path-plane angle, and main rotor thrust combinations. The effects of repositioning the tail rotor in the main rotor wake and the corresponding tail rotor countertorque requirements were determined. Each rotor was subsequently tested in isolation at the thrust and angle of attack combinations for trim. The acoustic data indicated that the noise was primarily dominated by the main rotor, especially for moderate speed main rotor blade-vortex interaction conditions. The tail rotor noise increased when the main rotor was removed indicating that tail rotor inflow was improved with the main rotor present

    A describing function analysis in closed loop systems with pulse frequency modulators

    Get PDF
    Describing functions for stability analysis of integral pulse frequency modulated unity feedback closed loop syste

    Visual sensitivity tester

    Get PDF
    Testing device uses closed loop film cassettes to project programmed visual stimuli on screen which the observer views through a lens making the stimuli appear to be at optical infinity. Tester is useful for determining changes in glautomatous visual field sensitivity

    Visual examination apparatus

    Get PDF
    An automated visual examination apparatus for measuring visual sensitivity and mapping blind spot location including a projection system for displaying to a patient a series of visual stimuli. A response switch enables him to indicate his reaction to the stimuli, and a recording system responsive to both the visual stimuli per se and the patient's response. The recording system thereby provides a correlated permanent record of both stimuli and response from which a substantive and readily apparent visual evaluation can be made

    Visual examination apparatus

    Get PDF
    An automated visual examination apparatus for measuring visual sensitivity and mapping blind spot location is described. The apparatus includes a projection system for displaying to a patient a series of visual stimuli, a response switch enabling him to indicate his reaction to the stimuli, and a recording system responsive to both the visual stimuli per se and the patient's response. The recording system provides a correlated permanent record of both stimuli and response from which a substantive and readily apparent visual evaluation can be made

    A corrosion control manual for rail rapid transit

    Get PDF
    In 1979, during the planning stage of the Metropolitan Dade County Transit System, the need was expressed for a corrosion control manual oriented to urban rapid transit system use. This manual responds to that need. The objective of the manual is to aid rail rapid transit agencies by providing practical solutions to selected corrosion problems. The scope of the manual encompasses corrosion problems of the facilities of rapid transit systems: structures and tracks, platforms and stations, power and signals, and cars. It also discusses stray electric current corrosion. Both design and maintenance solutions are provided for each problem. Also included are descriptions of the types of corrosion and their causes, descriptions of rapid transit properties, a list of corrosion control committees and NASA, DOD, and ASTM specifications and design criteria to which reference is made in the manual. A bibliography of papers and excerpts of reports and a glossary of frequency used terms are provided

    Bonding with Self-etching Primers – Pumice or Pre-etch? An \u3cem\u3ein vitro\u3c/em\u3e Study

    Get PDF
    The purpose of this study was to compare the shear bond strengths (SBSs) of orthodontic brackets bonded with self-etching primer (SEP) using different enamel surface preparations. A two-by-two factorial study design was used. Sixty human premolars were harvested, cleaned, and randomly assigned to four groups (n = 15 per group). Teeth were bathed in saliva for 48 hours to form a pellicle. Treatments were assigned as follows: group 1 was pumiced for 10 seconds and pre-etched for 5 seconds with 37 per cent phosphoric acid before bonding with SEP (Transbond Plus). Group 2 was pumiced for 10 seconds before bonding. Group 3 was pre-etched for 5 seconds before bonding. Group 4 had no mechanical or chemical preparation before bonding. All teeth were stored in distilled water for 24 hours at 37°C before debonding. The SBS values and adhesive remnant index (ARI) score were recorded. The SBS values (±1 SD) for groups 1–4 were 22.9 ± 6.6, 16.1 ± 7.3, 36.2 ± 8.2, and 13.1 ± 10.1 MPa, respectively. Two-way analysis of variance and subsequent contrasts showed statistically significant differences among treatment groups. ARI scores indicated the majority of adhesive remained on the bracket for all four groups. Pre-etching the bonding surface for 5 seconds with 37 per cent phosphoric acid, instead of pumicing, when using SEPs to bond orthodontic brackets, resulted in greater SBSs

    Molecular Characterisation of Bacteriophage K Towards Applications for the Biocontrol of Pathogenic Staphylococci

    Get PDF
    End of project reportThe aim of this work was to characterise staphylococcal bacteriophage (a bacterial virus) and to assess their potential as therapeutic agents against pathogenic strains of Staphylococcus aureus, particularly mastitis-causing strains. The project included the use of two newly isolated phage CS1 and DW2, and an existing polyvalent phage. The new phage were isolated from the farmyard and characterised by electron microscopy and restriction analysis. Both phage were shown to belong to the Siphoviridae family and were lytic for representatives of all three clonal groups of Irish mastitis-associated staphylococci. A cocktail of three phage (CS1, DW2 and K) at 108 (plaque forming units) PFU/ml was infused into cows teats in animal trials. The lack of an increase in somatic cell counts in milks indicated strongly that the phage did not irritate the animal. In addition, the most potent phage used in this study, phage K, was further studied by genome sequencing, which revealed a linear DNA genome of 127,395 base pairs, which encodes 118 putative ORFs (open reading frames)

    Bonding with Self-etching Primers – Pumice or Pre-etch? An \u3cem\u3ein vitro\u3c/em\u3e Study

    Get PDF
    The purpose of this study was to compare the shear bond strengths (SBSs) of orthodontic brackets bonded with self-etching primer (SEP) using different enamel surface preparations. A two-by-two factorial study design was used. Sixty human premolars were harvested, cleaned, and randomly assigned to four groups (n = 15 per group). Teeth were bathed in saliva for 48 hours to form a pellicle. Treatments were assigned as follows: group 1 was pumiced for 10 seconds and pre-etched for 5 seconds with 37 per cent phosphoric acid before bonding with SEP (Transbond Plus). Group 2 was pumiced for 10 seconds before bonding. Group 3 was pre-etched for 5 seconds before bonding. Group 4 had no mechanical or chemical preparation before bonding. All teeth were stored in distilled water for 24 hours at 37°C before debonding. The SBS values and adhesive remnant index (ARI) score were recorded. The SBS values (±1 SD) for groups 1–4 were 22.9 ± 6.6, 16.1 ± 7.3, 36.2 ± 8.2, and 13.1 ± 10.1 MPa, respectively. Two-way analysis of variance and subsequent contrasts showed statistically significant differences among treatment groups. ARI scores indicated the majority of adhesive remained on the bracket for all four groups. Pre-etching the bonding surface for 5 seconds with 37 per cent phosphoric acid, instead of pumicing, when using SEPs to bond orthodontic brackets, resulted in greater SBSs

    Heterodyne detection of the 752.033-GHz H2O rotational absorption line

    Get PDF
    A tunable high resolution two stage heterodyne radiometer was developed for the purpose of investigating the intensity and lineshape of the 752.033 GHz rotational transition of water vapor. Single-sideband system noise temperatures of approximately 45,000 K were obtained using a sensitive GaAs Schottky diode as the first stage mixer. First local oscillator power was supplied by a CO2 laser pumped formic acid laser (761.61 GHz), generating an X-band IF signal with theoretical line center at 9.5744 GHz. Second local oscillator power was provided by means of a 3 GHz waveguide cavity filter with only 9 dB insertion loss. In absorption measurements of the H2O taken from a laboratory simulation of a high altitude rocket plume, the center frequency of the 752 GHz line was determined to within 1 MHz of the reported value. A rotational temperature 75 K, a linewidth 5 MHz and a Doppler shift 3 MHz were measured with the line-of-sight intersecting the simulated-plume axis at a distance downstream of 30 nozzle diameters. These absorption data were obtained against continuum background radiation sources at temperatures of 1175 and 300 K
    • …
    corecore