113 research outputs found

    Durrenentzen – Lotissement Oben an den Gaerten, rue des Commandos

    Get PDF
    Le projet de lotissement Oben an des Gaerten en bordure sud du village de Durrenentzen, rue des Commandos, a suscité la prescription d’un diagnostic archéologique, réalisé en octobre 2015, qui a révélé la présence de 14 barres de fer bipyramidales. La présence d’un obus au même niveau que les barres a nécessité l’intervention d’une équipe de déminage ne permettant pas un relevé précis de la découverte. Afin d’en appréhender le contexte, une fouille archéologique préventive a été prescrite sur..

    Cadmium exposure and risk of prediabetes and diabetes: A systematic review and dose-response meta-analysis

    Get PDF
    BACKGROUND AND AIM: Elevated cadmium exposure has been associated with altered glucose metabolism, albeit the shape of such relation is still debated. We aimed at investigating the shape of the relation between cadmium exposure and type 2 diabetes and prediabetes. METHODS: We performed a systematic review with meta-analysis on the relation between biomarkers of cadmium exposure and disease risk. After performing an online literature search through March 15, 2021, we identified 34 eligible studies with cohort, cross-sectional and case-control design. RESULTS:In the meta-analysis comparing highest-versus-lowest cadmium exposure, there was an increased type 2 diabetes risk, with summary risk ratios (RRs) of 1.30 (95% confidence interval (CI): 1.00-1.69), 1.22 (95% CI 1.00-1.50), and 1.47 (95% CI 1.01-2.13) for blood, urine, and toenail cadmium concentrations, respectively. Similarly, we found a higher prediabetes risk in subjects with higher both urine and blood cadmium concentrations with RRs of 1.41 (95% CI 1.15-1.73) and 1.38 (95% CI 1.16-1.63), respectively. In the dose-response meta-analysis, compared with no exposure, prediabetes risk increased up to approximately 2 µg Cd/g creatinine, above which it reached a plateau with RR of 1.40 (95% CI 1.12-1.76) at 2 µg Cd/g creatinine. We also detected a substantial linear positive association between diabetes risk and urinary cadmium, with RR of 1.30 (95% CI 0.92-1.84) at 2.0 µg Cd/g creatinine. Diabetes risk also appeared to increase with higher blood cadmium concentrations but only above 1 µg/L, with RR of 3.25 (95% CI 1.13-9.37) at 2 µg/L. Despite limited data, there was little indication of differences in association by study design (cohort vs. case-control or cross-sectional), method of cadmium assessment, or sex (male vs. female). CONCLUSIONS:Overall, there was consistent evidence for a positive association between cadmium exposure and both prediabetes and diabetes risk. KEYWORDS: Heavy metals, Cardiovascular diseases, Endocrine disrupting chemicals, Environmental epidemiology, Toxicolog

    Deficient calcium, zinc, and iron intake on absorption of cadmium from diet

    Get PDF
    Background/Aim: In vitro and in vivo studies have demonstrated that deficient calcium, zinc, and iron dietary intake upregulates metal ion transporters to increase intestinal absorption. However, these gut transporters are not specific and bind to other metals, including cadmium. Few human studies have investigated whether deficient calcium, zinc, and iron intake increases intestinal absorption of dietary cadmium. Methods: We used enrollment data (2010-2012) from the Study of Environment, Lifestyle & Fibroids, a cohort of 1693 African American women ages 23-35 who reside in the Detroit, Michigan area. Whole blood cadmium concentrations (proxy for cadmium absorption) were measured in 1548 participants. Dietary and supplemental calcium, zinc, and iron intake was estimated using Block 2005 Food Frequency Questionnaire data; deficient intake was defined as <80% of the recommended daily allowance. Daily dietary intake of total grains was used as the proxy for dietary cadmium intake as grains are a major source of cadmium exposure in U.S. diet. We estimated the percent difference in blood cadmium concentrations per median daily intake of total grains (4.55 ounce equivalents) using multivariable linear regression, stratified by deficient and sufficient calcium, zinc, and/or iron intake. We restricted the analyses to never smokers with plausible values for total energy intake (>400 and <5000 kcal/day) (n=1087). We adjusted for age at enrollment, total energy intake, body mass index, height, education, and natural log-transformed blood lead concentrations. Results: The observed percent difference in blood cadmium concentrations in relation to intake of total grains was stronger among those with deficient intake of calcium, zinc, and/or iron (28%, 95% CI; 6, 53%) than among those with sufficient intake of all 3 essential nutrients (5%, 95% CI: -7, 19%). Conclusions: Our preliminary findings suggest that women with deficient calcium, zinc, and/or iron intake have increased absorption of cadmium from the diet

    A cryogenic rotation stage with a large clear aperture for the half-wave plates in the Spider instrument

    Get PDF
    We describe the cryogenic half-wave plate rotation mechanisms built for and used in Spider, a polarization-sensitive balloon-borne telescope array that observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a stratospheric balloon flight from Antarctica in January 2015. The mechanisms operate at liquid helium temperature in flight. A three-point contact design keeps the mechanical bearings relatively small but allows for a large (305 mm) diameter clear aperture. A worm gear driven by a cryogenic stepper motor allows for precise positioning and prevents undesired rotation when the motors are depowered. A custom-built optical encoder system monitors the bearing angle to an absolute accuracy of +/- 0.1 degrees. The system performed well in Spider during its successful 16 day flight.Comment: 11 pages, 7 figures, Published in Review of Scientific Instruments. v2 includes reviewer changes and longer literature revie

    Design of 280 GHz feedhorn-coupled TES arrays for the balloon-borne polarimeter SPIDER

    Full text link
    We describe 280 GHz bolometric detector arrays that instrument the balloon-borne polarimeter SPIDER. A primary science goal of SPIDER is to measure the large-scale B-mode polarization of the cosmic microwave background in search of the cosmic-inflation, gravitational-wave signature. 280 GHz channels aid this science goal by constraining the level of B-mode contamination from galactic dust emission. We present the focal plane unit design, which consists of a 16×\times16 array of conical, corrugated feedhorns coupled to a monolithic detector array fabricated on a 150 mm diameter silicon wafer. Detector arrays are capable of polarimetric sensing via waveguide probe-coupling to a multiplexed array of transition-edge-sensor (TES) bolometers. The SPIDER receiver has three focal plane units at 280 GHz, which in total contains 765 spatial pixels and 1,530 polarization sensitive bolometers. By fabrication and measurement of single feedhorns, we demonstrate 14.7^{\circ} FHWM Gaussian-shaped beams with <<1% ellipticity in a 30% fractional bandwidth centered at 280 GHz. We present electromagnetic simulations of the detection circuit, which show 94% band-averaged, single-polarization coupling efficiency, 3% reflection and 3% radiative loss. Lastly, we demonstrate a low thermal conductance bolometer, which is well-described by a simple TES model and exhibits an electrical noise equivalent power (NEP) = 2.6 ×\times 1017^{-17} W/Hz\sqrt{\mathrm{Hz}}, consistent with the phonon noise prediction.Comment: Proceedings of SPIE Astronomical Telescopes + Instrumentation 201

    Pointing control for the SPIDER balloon-borne telescope

    Full text link
    We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI control loop runs on a digital signal processor, with feedback from fibre optic rate gyroscopes. This system can control azimuthal speed with < 0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven linear actuators to rotate the cryostat, which houses the optical instruments, relative to the outer frame. With the velocity in each axis controlled in this way, higher-level control loops on the onboard flight computers can implement the pointing and scanning observation modes required for the experiment. We have accomplished the non-trivial task of scanning a 5000 lb payload sinusoidally in azimuth at a peak acceleration of 0.8 deg/s2^2, and a peak speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing control accuracy.Comment: 20 pages, 12 figures, Presented at SPIE Ground-based and Airborne Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume 914

    Toward Defining the Preclinical Stages of Alzheimer's Disease: Recommendations from the National Institute on Aging-Alzheimer's Association Workgroups on Diagnostic Guidelines for Alzheimer's Disease

    Get PDF
    The pathophysiological process of Alzheimer's disease (AD) is thought to begin many years before the diagnosis of AD dementia. This long "preclinical" phase of AD would provide a critical opportunity for therapeutic intervention; however, we need to further elucidate the link between the pathological cascade of AD and the emergence of clinical symptoms. The National Institute on Aging and the Alzheimer's Association convened an international workgroup to review the biomarker, epidemiological, and neuropsychological evidence, and to develop recommendations to determine the factors which best predict the risk of progression from "normal" cognition to mild cognitive impairment and AD dementia. We propose a conceptual framework and operational research criteria, based on the prevailing scientific evidence to date, to test and refine these models with longitudinal clinical research studies. These recommendations are solely intended for research purposes and do not have any clinical implications at this time. It is hoped that these recommendations will provide a common rubric to advance the study of preclinical AD, and ultimately, aid the field in moving toward earlier intervention at a stage of AD when some disease-modifying therapies may be most efficacious
    corecore