12 research outputs found
Graph-based Deep Reinforcement Learning for Wind Farm Set-Point Optimisation
Wake steering is a form of wind farm control in which upstream turbines are deliberately yawed to misalign with the free-stream wind in order to prevent their wakes from impacting turbines further downstream. This technique can give a net increase in power generated by an array of turbines compared to greedy control, but the optimisation of multiple turbine set-points under varying wind conditions can be infeasibly complex for traditional, whitebox models. In this work, a novel deep reinforcement learning method combining the standard Deep Deterministic Policy Gradient algorithm with a graph representation of potential inter-turbine wake connections was trained to apply wake steering to an array of nine turbines under varying wind directions. The method demonstrated strong performance for wind directions with large potential farm power gains. A steady-state wind farm solver was used, employing a “quasi-dynamic” approach to sampling wind directions, to achieve an additional 47 MW (6.5%) power over four wind directions compared to greedy control
MaasPenn Radiomics Reproducibility Score:A Novel Quantitative Measure for Evaluating the Reproducibility of CT-Based Handcrafted Radiomic Features
Simple Summary: The reproducibility of handcrafted radiomic features (HRFs) has been reported to be affected by variations in imaging acquisition and reconstruction parameters. However, to date, these effects have not been understood or quantified. In this study, we analyzed a significantly large number of scenarios in an effort to quantify the effects of variations on the reproducibility of HRFs. In addition, we assessed the performance of ComBat harmonization in each of the 31,375 investigated scenarios. We developed a novel score that can be considered the first attempt to objectively assess the number of reproducible HRFs in different scenario. Following further validation, the score could be used to decide on the inclusion of data acquired differently, as well as the assessment of the generalizability of developed radiomic signatures. Abstract: The reproducibility of handcrafted radiomic features (HRFs) has been reported to be affected by variations in imaging parameters, which significantly affect the generalizability of developed signatures and translation to clinical practice. However, the collective effect of the variations in imaging parameters on the reproducibility of HRFs remains unclear, with no objective measure to assess it in the absence of reproducibility analysis. We assessed these effects of variations in a large number of scenarios and developed the first quantitative score to assess the reproducibility of CT-based HRFs without the need for phantom or reproducibility studies. We further assessed the potential of image resampling and ComBat harmonization for removing these effects. Our findings suggest a need for radiomics-specific harmonization methods. Our developed score should be considered as a first attempt to introduce comprehensive metrics to quantify the reproducibility of CT-based handcrafted radiomic features. More research is warranted to demonstrate its validity in clinical contexts and to further improve it, possibly by the incorporation of more realistic situations, which better reflect real patients' situations
Impact of Tomosynthesis Acquisition on 3D Segmentations of Breast Outline and Adipose/Dense Tissue with AI: A Simulation-Based Study
Digital breast tomosynthesis (DBT) reconstructions introduce out-of-plane artifacts and false-tissue boundaries impacting the dense/adipose and breast outline (convex hull) segmentations. A virtual clinical trial method was proposed to segment both the breast tissues and the breast outline in DBT reconstructions. The DBT images of a representative population were simulated using three acquisition geometries: a left–right scan (conventional, I), a two-directional scan in the shape of a “T” (II), and an extra-wide range (XWR, III) left–right scan at a six-times higher dose than I. The nnU-Net was modified including two losses for segmentation: (1) tissues and (2) breast outline. The impact of loss (1) and the combination of loss (1) and (2) was evaluated using models trained with data simulating geometry I. The impact of the geometry was evaluated using the combined loss (1&2). The loss (1&2) improved the convex hull estimates, resolving 22.2% of the false classification of air voxels. Geometry II was superior to I and III, resolving 99.1% and 96.8% of the false classification of air voxels. Geometry III (Dice = (0.98, 0.94)) was superior to I (0.92, 0.78) and II (0.93, 0.74) for the tissue segmentation (adipose, dense, respectively). Thus, the loss (1&2) provided better segmentation, and geometries T and XWR improved the dense/adipose and breast outline segmentations relative to the conventional scan
Multiclass Segmentation of Breast Tissue and Suspicious Findings: A Simulation-Based Study for the Development of Self-Steering Tomosynthesis
In breast tomosynthesis, multiple low-dose projections are acquired in a single scanning direction over a limited angular range to produce cross-sectional planes through the breast for three-dimensional imaging interpretation. We built a next-generation tomosynthesis system capable of multidirectional source motion with the intent to customize scanning motions around “suspicious findings”. Customized acquisitions can improve the image quality in areas that require increased scrutiny, such as breast cancers, architectural distortions, and dense clusters. In this paper, virtual clinical trial techniques were used to analyze whether a finding or area at high risk of masking cancers can be detected in a single low-dose projection and thus be used for motion planning. This represents a step towards customizing the subsequent low-dose projection acquisitions autonomously, guided by the first low-dose projection; we call this technique “self-steering tomosynthesis.” A U-Net was used to classify the low-dose projections into “risk classes” in simulated breasts with soft-tissue lesions; class probabilities were modified using post hoc Dirichlet calibration (DC). DC improved the multiclass segmentation (Dice = 0.43 vs. 0.28 before DC) and significantly reduced false positives (FPs) from the class of the highest risk of masking (sensitivity = 81.3% at 2 FPs per image vs. 76.0%). This simulation-based study demonstrated the feasibility of identifying suspicious areas using a single low-dose projection for self-steering tomosynthesis
Novel Perlin-based phantoms using 3D models of compressed breast shapes and fractal noise
Virtual clinical trials (VCTs) have been used widely to evaluate digital breast tomosynthesis (DBT) systems. VCTs require realistic simulations of the breast anatomy (phantoms) to characterize lesions and to estimate risk of masking cancers. This study introduces the use of Perlin-based phantoms to optimize the acquisition geometry of a novel DBT prototype. These phantoms were developed using a GPU implementation of a novel library called Perlin-CuPy. The breast anatomy is simulated using 3D models under mammography cranio-caudal compression. In total, 240 phantoms were created using compressed breast thickness, chest-wall to nipple distance, and skin thickness that varied in a {[35, 75], [59, 130), [1.0, 2.0]} mm interval, respectively. DBT projections and reconstructions of the phantoms were simulated using two acquisition geometries of our DBT prototype. The performance of both acquisition geometries was compared using breast volume segmentations of the Perlin phantoms. Results show that breast volume estimates are improved with the introduction of posterior-anterior motion of the x-ray source in DBT acquisitions. The breast volume is overestimated in DBT, varying substantially with the acquisition geometry; segmentation errors are more evident for thicker and larger breasts. These results provide additional evidence and suggest that custom acquisition geometries can improve the performance and accuracy in DBT. Perlin phantoms help to identify limitations in acquisition geometries and to optimize the performance of the DBT prototypes