5,753 research outputs found

    The fundamental parameters of the roAp star 10 Aql

    Full text link
    Due to the strong magnetic field and related abnormal surface layers existing in rapidly oscillating Ap stars, systematic errors are likely to be present when determining their effective temperatures, which potentially compromises asteroseismic studies of these pulsators. Using long-baseline interferometry, our goal is to determine accurate angular diameters of a number of roAp targets to provide a temperature calibration for these stars. We obtained interferometric observations of 10 Aql with the visible spectrograph VEGA at the CHARA array. We determined a limb-darkened angular diameter of 0.275+/-0.009 mas and deduced a linear radius of 2.32+/-0.09 R_sun. We estimated the star's bolometric flux and used it, in combination with its parallax and angular diameter, to determine the star's luminosity and effective temperature. For two data sets of bolometric flux we derived an effective temperature of 7800+/-170 K and a luminosity of 18+/-1 L_sun or of 8000+/-210 K and 19+/-2 L_sun. We used these fundamental parameters together with the large frequency separation to constrain the mass and the age of 10 Aql, using the CESAM stellar evolution code. Assuming a solar chemical composition and ignoring all kinds of diffusion and settling of elements, we obtained a mass of 1.92 M_sun and an age of 780 Gy or a mass of 1.95 M_sun and an age of 740 Gy, depending on the considered bolometric flux. For the first time, we managed to determine an accurate angular diameter for a star smaller than 0.3 mas and to derive its fundamental parameters. In particular, by only combining our interferometric data and the bolometric flux, we derived an effective temperature that can be compared to those derived from atmosphere models. Such fundamental parameters can help for testing the mechanism responsible for the excitation of the oscillations observed in the magnetic pulsating stars

    Improving the surface brightness-color relation for early-type stars using optical interferometry

    Full text link
    The aim of this work is to improve the SBC relation for early-type stars in the 1VK0-1 \leq V-K \leq 0 color domain, using optical interferometry. Observations of eight B- and A-type stars were secured with the VEGA/CHARA instrument in the visible. The derived uniform disk angular diameters were converted into limb darkened angular diameters and included in a larger sample of 24 stars, already observed by interferometry, in order to derive a revised empirical relation for O, B, A spectral type stars with a V-K color index ranging from -1 to 0. We also took the opportunity to check the consistency of the SBC relation up to VK4V-K \simeq 4 using 100 additional measurements. We determined the uniform disk angular diameter for the eight following stars: γ\gamma Ori, ζ\zeta Per, 88 Cyg, ι\iota Her, λ\lambda Aql, ζ\zeta Peg, γ\gamma Lyr, and δ\delta Cyg with V-K color ranging from -0.70 to 0.02 and typical precision of about 1.5%1.5\%. Using our total sample of 132 stars with VKV-K colors index ranging from about 1-1 to 44, we provide a revised SBC relation. For late-type stars (0VK40 \leq V-K \leq 4), the results are consistent with previous studies. For early-type stars (1VK0-1 \leq V-K \leq 0), our new VEGA/CHARA measurements combined with a careful selection of the stars (rejecting stars with environment or stars with a strong variability), allows us to reach an unprecedented precision of about 0.16 magnitude or 7%\simeq 7\% in terms of angular diameter.Comment: 13 pages, 5 figures, accepted for publication in A&

    Respiratory patient experience of measures to reduce risk of COVID-19: findings from a descriptive cross-sectional UK wide survey

    Get PDF
    Objectives: To assess the experience of people with long-term respiratory conditions regarding the impact of measures to reduce risk of COVID-19. Design: Analysis of data (n=9,515) from the Asthma UK and British Lung Foundation partnership COVID-19 survey collected online between 1st and 8th of April 2020. Setting: Community Participants: 9,515 people with self-reported long term respiratory conditions. 81% female, age ranges from <17 years to 80 and above, from all nations of the UK. Long term respiratory conditions reported included asthma (83%), Chronic Obstructive Pulmonary Disease (COPD) (10%), bronchiectasis (4%), Interstitial Lung Disease (ILD) (2%), and ‘other’ (<1%) (e.g. lung cancer and pulmonary endometriosis). Outcome measures: Study responses related to impacts on key elements of health care, as well as practical, psychological and social consequences related to the COVID-19 pandemic and social distancing measures. Results: 45% reported disruptions to care, including cancellations of appointments, investigations, pulmonary rehabilitation, treatment, and monitoring. Other practical impacts such as difficulty accessing healthcare services for other issues, and getting basic necessities such as food, were also common. 36% did not use online prescriptions and 54% had not accessed online inhaler technique videos. Psycho-social impacts including anxiety, loneliness and concerns about personal health and family were prevalent. 81% reported engaging in physical activity. Among the 11% who were smokers, 48% reported they were planning to quit smoking because of COVID-19. Conclusions: COVID-19 and related social distancing measures are having profound impacts on people with chronic respiratory conditions. Urgent adaptation and signposting of services is required to mitigate the negative health consequences of the COVID-19 response for this group

    Field experiments on dishonesty and stealing: what have we learned in the last 40 years?

    Get PDF
    ObjectivesField experiments combine the benefits of the experimental method and the study of human behavior in real-life settings, providing high internal and external validity. This article aims to review the field experimental evidence on the causes of offending.MethodsWe carried out a systematic search for field experiments studying stealing or monetary dishonesty reported since 1979.ResultsThe search process resulted in 60 field experiments conducted within multiple fields of study, mainly in economics and management, which were grouped into four categories: Fraudulent/ dishonest behavior, Stealing, Keeping money, and Shoplifting.ConclusionsThe reviewed studies provide a wide variety of methods and techniques that allow the real-world study of influences on offending and dishonest behavior. We hope that this summary will inspire criminologists to design and carry out realistic field experiments to test theories of offending, so that criminology can become an experimental science.This study was conducted at the Psychology Research Centre (CIPsi/UM) School of Psychology, University of Minho, supported by the Foundation for Science and Technology (FCT) through the Portuguese State Budget (UIDB/01662/2020). The first author was supported by a doctoral grant from the Portuguese Foundation for Science and Technology (FCT - SFRH/BD/122919/2016)

    Imaging the Algol Triple System in H Band with the CHARA Interferometer

    Full text link
    Algol (Beta Per) is an extensively studied hierarchical triple system whose inner pair is a prototype semi-detached binary with mass transfer occurring from the sub-giant secondary to the main-sequence primary. We present here the results of our Algol observations made between 2006 and 2010 at the CHARA interferometer with the Michigan Infrared Combiner in the H band. The use of four telescopes with long baselines allows us to achieve better than 0.5 mas resolution and to unambiguously resolve the three stars. The inner and outer orbital elements, as well as the angular sizes and mass ratios for the three components are determined independently from previous studies. We report a significantly improved orbit for the inner stellar pair with the consequence of a 15% change in the primary mass compared to previous studies. We also determine the mutual inclination of the orbits to be much closer to perpendicularity than previously established. State-of-the-art image reconstruction algorithms are used to image the full triple system. In particular an image sequence of 55 distinct phases of the inner pair orbit is reconstructed, clearly showing the Roche-lobe-filling secondary revolving around the primary, with several epochs corresponding to the primary and secondary eclipses

    The post-hemodialysis rebound: Predicting and quantifying its effect on Kt/V

    Get PDF
    The post-hemodialysis rebound: Predicting and quantifying its effect on Kt/V. Immediately after hemodialysis, the urea concentration rebounds upwards as urea continues to be transferred into the arterial circulation from peripheral body compartments. This rebound takes at least 30 minutes to complete. Hemodialysis is quantified as the Kt/V, calculated prom pre- and post-dialysis urea samples. Unless the post-dialysis sample is taken at least 30 minutes after dialysis, the Kt/V will be overestimated. This overestimation will be relatively greater in short high-efficiency dialyses, which have greater post-dialysis rebounds. We propose a method of correction that uses only the conventional pre- and immediate post-dialysis samples and is based on the physiologically-appropriate patient clearance time (tp). This is the time needed to clear all body compartments when the dialyzer clearance is infinite. The tp can be calculated from the pre-, immediate post- and 30-minute post-dialysis urea concentrations and was 35 minutes (SD 16) in 29 patients undergoing short (149 min) hemodiafiltration and standard (243 min) hemodialysis the following week. There was no significant difference between tp values calculated during the two treatments. Standard Kt/V can be corrected by multiplying by t/(t + tp) and dialysis time should be increased by tp × Kt/V minutes to compensate for the rebound. Despite individual variations in tp, a value of tp = 35 was sufficient to correct Kt/V in all patients. Kt/V corrected in this way agreed with Kt/V calculated using a 60-minute post-dialysis sample (r = 0.856, P < 0.001). The method predicted the 60-minute post-rebound concentration (SE 0.5mM, r = 0.983, P < 0.001) and the addition of 35 minutes to the treatment time corrected for the rebound in both conventional and short treatments. Similar simple equations corrected the error in V caused by rebound effects
    corecore