49 research outputs found

    Transfemoral versus transcarotid access for transcatheter aortic valve replacement

    Get PDF
    Objectives: To compare the outcomes after transcatheter aortic valve replacement (TAVR) through a transfemoral (TF) and transcarotid (TC) access at our institution. Methods: From January 2014 to January 2020, 62 TC-TAVR and 449 TF-TAVR were performed using 2 prosthesis devices (Edwards SAPIEN 3, n = 369; Medtronic Evolut R, n = 142). Propensity score matching was used to adjust for imbalance in the baseline characteristics of the study groups. Results: Propensity score matching provided 62 matched pairs with comparable operative risk (mean European System for Cardiac Operative Risk Evaluation II, TC-TAVR 7.6% vs TF-TAVR 6.6%, P = .17). Thirty-day mortality (4.8% vs 3.2%, P = 1.00) and 2-year mortality (11.3% vs 12.9%, P = .64) after TC-TAVR were comparable with TF-TAVR. Strokes were numerically more frequent after TC-TAVR compared with TF-TAVR (3.2% vs 0%, P = .23), but the difference did not reach statistical significance. TF-TAVR was associated with a significantly greater risk of permanent pacemaker implantation (29.0% vs 12.9%, P = .04) compared with TC-TAVR. Other complications were not frequent and were similarly distributed between the matched groups. Conclusions: TC access for TAVR was associated with satisfactory results compared to the femoral access. TC-TAVR could be considered a valid and safe alternative to TF-TAVR when femoral access is contraindicated. © 2022</p

    The SURFEXv7.2 land and ocean surface platform for coupled or offline simulation of Earth surface variables and fluxes

    Get PDF
    CC Attribution 3.0 License.Final revised paper also available at http://www.geosci-model-dev.net/6/929/2013/gmd-6-929-2013.pdfInternational audienceSURFEX is a new externalized land and ocean surface platform that describes the surface fluxes and the evolution of four types of surface: nature, town, inland water and ocean. It can be run either coupled or in offline mode. It is mostly based on pre-existing, well validated scientific models. It can be used in offline mode (from point scale to global runs) or fully coupled with an atmospheric model. SURFEX is able to simulate fluxes of carbon dioxide, chemical species, continental aerosols, sea salt and snow particles. It also includes a data assimilation module. The main principles of the organization of the surface are described first. Then, a survey is made of the scientific module (including the coupling strategy). Finally the main applications of the code are summarized. The current applications are extremely diverse, ranging from surface monitoring and hydrology to numerical weather prediction and global climate simulations. The validation work undertaken shows that replacing the pre-existing surface models by SURFEX in these applications is usually associated with improved skill, as the numerous scientific developments contained in this community code are used to good advantage

    Transcarotid Access Versus Transfemoral Access for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

    No full text
    Background: The transfemoral (TF) route is the gold-standard access for transcatheter aortic valve replacement (TAVR). In 10-15% of patients, alternative accesses are needed, such as the transcarotid (TC) access. We performed a meta-analysis to compare 30-day mortality and complications between TC-TAVR and TF-TAVR. Methods: We searched PubMed/MEDLINE and EMBASE from inception to January 2021 to identify articles comparing TC-TAVR and TF-TAVR. Patients' baseline characteristics, procedural outcomes, and clinical 30-day outcomes were extracted. Results: We identified 9 studies, among which 2 used propensity-score matching, including 1,374 TC patients and 3,706 TF patients. TC-TAVR was associated with significantly higher EuroSCORE II and Logistic EuroSCORE values (respectively 8.0 ± 6.7 vs. 6.3 ± 5.4, p = 0.002 and 20.8 ± 14.2% vs. 20.0 ± 13.4%, p = 0.04), a higher prevalence of peripheral artery disease (52.6 vs. 32.8%, p = 0.001), previous cardiac surgery (26.3 vs. 22.4%, p = 0.008) and coronary artery disease (64.6 vs. 60.5%, p = 0.020). The pooled results found TC-TAVR to be associated with a significantly higher 30-day mortality risk (RR, 1.41, 95% CI, 1.02-1.96, p = 0.040), and a lower rate of 30-day major vascular complications (RR, 0.48, 95% CI, 0.25-0.92, p = 0.030). No significant difference was found regarding permanent pacemaker implantation, major bleeding and acute kidney injury. A subgroup analysis of the two propensity-score matched studies found a statistically increased risk of 30-day neurovascular complications (RR, 1.61, 95% CI, 1.02-2.55, p = 0.040). Conclusion: Compared with TF-TAVR, TC-TAVR was associated with an increased risk of 30-day mortality, likely related to a higher surgical risk and comorbidity burden, and with an increased risk of 30-day neurovascular complications. Careful preprocedural patient selection and close periprocedural neurological monitoring are paramount
    corecore