52 research outputs found

    Additional data from clinical examination on site significantly but marginally improve predictive accuracy of the Revised Trauma Score for major complications during Helicopter Emergency Medical Service missions

    Get PDF
    Introduction: The Revised Trauma Score (RTS) accurately identifies trauma patients at high risk of adverse events or death. Less is known about its usefulness in the general population and non-trauma recipients of Helicopter Emergency Medical Service (HEMS). The RTS is a simple tool and omits a lot of other data obtained during clinical evaluation. The aim was to assess the role of the RTS to identify patients at risk of major complications (death, cardiopulmonary resuscitation, defibrillation, intubation) in the general population of HEMS patients. Clinical factors beyond the RTS were analyzed to identify additional prognostic factors for predicting major complications. Material and methods: A retrospective analysis of medical records of adult patients routinely collected during HEMS missions in the years 2011-2014 was performed. Results: The analysis included 19 554 HEMS missions. Patients were 55 ±20 years old and 68% were male. The most common indication for HEMS was diseases of the circulatory system - 41%. Major complications occurred in 2072 (10.6%) cases. In the general population of HEMS patients, the RTS accurately identified individuals at risk of major complications at a cut-off value of 10.5 and area under the curve (AUC) of 93.5%. In multivariate analysis, additional clinical data derived from clinical examination (ECG; skin, pupil and breathing examination) significantly but marginally improved the accuracy of RTS assessment: AUC 95.6% (p < 0.001 for the difference). Conclusions: The Revised Trauma Score accurately identifies individuals at risk of major complications during HEMS missions regardless of the indication. Additional clinical data significantly but marginally improved the accuracy of RTS in the general population of HEMS patient

    Length of hospital stay for elective electrophysiological procedures: a survey from the European Heart Rhythm Association

    Get PDF
    AIMS: Electrophysiological (EP) operations that have traditionally involved long hospital lengths of stay (LOS) are now being undertaken as day case procedures. The coronavirus disease-19 pandemic served as an impetus for many centres to shorten LOS for EP procedures. This survey explores LOS for elective EP procedures in the modern era. METHODS AND RESULTS: An online survey consisting of 27 multiple-choice questions was completed by 245 respondents from 35 countries. With respect to de novo cardiac implantable electronic device (CIED) implantations, day case procedures were reported for 79.5% of implantable loop recorders, 13.3% of pacemakers (PMs), 10.4% of implantable cardioverter defibrillators (ICDs), and 10.2% of cardiac resynchronization therapy (CRT) devices. With respect to CIED generator replacements, day case procedures were reported for 61.7% of PMs, 49.2% of ICDs, and 48.2% of CRT devices. With regard to ablations, day case procedures were reported for 5.7% of atrial fibrillation (AF) ablations, 10.7% of left-sided ablations, and 17.5% of right-sided ablations. A LOS ≥ 2 days for CIED implantation was reported for 47.7% of PM, 54.5% of ICDs, and 56.9% of CRT devices and for 54.5% of AF ablations, 42.2% of right-sided ablations, and 46.1% of left-sided ablations. Reimbursement (43-56%) and bed availability (20-47%) were reported to have no consistent impact on the organization of elective procedures. CONCLUSION: There is a wide variation in the LOS for elective EP procedures. The LOS for some procedures appears disproportionate to their complexity. Neither reimbursement nor bed availability consistently influenced LOS

    Effectiveness and safety of a single freeze strategy of cryoballoon ablation of atrial fibrillation: an EHRA systematic review and meta-analysis

    Get PDF
    To conduct a systematic review and meta-analysis to compare the effectiveness and safety of cryoballoon ablation of atrial fibrillation (AF) performed using a single freeze strategy in comparison to an empiric double ('bonus') freeze strategy. We systematically searched MEDLINE, EMBASE, and CENTRAL databases from inception to 12 July 2020, for prospective and retrospective studies of patients undergoing cryoballoon for paroxysmal or persistent AF comparing a single vs. bonus freeze strategy. The main outcome was atrial arrhythmia-free survival and eligible studies required at least 12 months of follow-up; the primary safety outcome was a composite of all complications. Study quality was assessed using the Cochrane risk of bias tool and the Newcastle-Ottawa Scale. Thirteen studies (3 randomized controlled trials and 10 observational studies) comprising 3163 patients were eligible for inclusion (64% males, 71.5% paroxysmal AF, mean CHA2DS2-VASc score 1.3 ± 0.9). There was no significant difference in pooled effectiveness between single freeze strategy compared to double freeze strategy [relative risk (RR) 1.03; 95% confidence interval (CI): 0.98-1.07; I2 = 0%]. Single freeze procedures were associated with a significantly lower adverse event rate (RR 0.72; 95% CI: 0.53-0.98; I2 = 0%) and shorter average procedure time (90 ± 27 min vs. 121 ± 36 min, P < 0.001). A trend for lower risk of persistent phrenic nerve palsy was observed (RR 0.61; 95% CI: 0.37-1.01; I2 = 0%). The quality of included studies was moderate/good, with no evidence of significant publication bias. Single freeze strategy for cryoballoon of AF is as effective as an empiric double ('bonus') freeze strategy while appearing safer and probably quicker

    Regional disparity on patient characteristics and perceptions after implantable cardioverter-defibrillator implantation: results from an EHRA patient survey

    Get PDF
    AIMS: The aim of this study was to identify potential regional disparities in characteristics of implantable cardioverter-defibrillator (ICD) recipients, patient perceptions and perspectives after implantation and level of information provided to patients. METHODS AND RESULTS: The prospective, multicentre, and multinational European Heart Rhythm Association patient Survey 'Living with an ICD' included patients already implanted with an ICD (median ICD dwell time - 5 years, interquartile range 2-10). An online questionnaire was filled-in by patients invited from 10 European countries. A total of 1809 patients (the majority in their 40s to 70s, 65.5% men) were enrolled, with 877 (48.5%) from Western Europe (group 1), followed by 563 from Central/Eastern Europe (group 2, 31.1%), and 369 from Southern Europe (group 3, 20.4%). A total of 52.9% of Central/Eastern Europe patients reported increased satisfaction after ICD placement compared with 46.6% from Western and 33.1% from Southern Europe (1 vs. 2 P = 0.047, 1 vs. 3 P < 0.001, 2 vs. 3 P < 0.001). About 79.2% of Central/Eastern and 76.0% of Southern Europe patients felt optimally informed at the time of device implantation compared with just 64.6% from Western Europe (1 vs. 2 P < 0.001, 1 vs. 3 P < 0.001, 2 vs. 3 P = ns). CONCLUSIONS: While physicians in Southern Europe should address the patients' concerns about the impact of the ICD on quality of life, physicians from Western Europe should focus on improving the quality of information provided to their prospective ICD patients. Novel strategies to address regional differences in patients' quality of life and provision of information are warranted

    Rhythm monitoring, success definition, recurrence, and anticoagulation after atrial fibrillation ablation: results from an EHRA survey

    Get PDF
    Atrial fibrillation (AF) is a major challenge for the healthcare field. Pulmonary vein isolation is the most effective treatment for the maintenance of sinus rhythm. However, clinical endpoints for the procedure vary significantly among studies. There is no consensus on the definition of recurrence and no clear roadmap on how to deal with recurrences after a failed ablation. The purpose of this study was to perform a survey in order to show how clinicians currently approach this knowledge gap. An online survey, supported by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee, was conducted between 1 April 2022 and 8 May 2022. An anonymous questionnaire was disseminated via social media and EHRA newsletters, for clinicians to complete. This consisted of 18 multiple-choice questions regarding rhythm monitoring, definitions of a successful ablation, clinical practices after a failed AF ablation, and the continuance of anticoagulation. A total of 107 replies were collected across Europe. Most respondents (82%) perform routine monitoring for AF recurrences after ablation, with 51% of them preferring a long-term monitoring strategy. Cost was reported to have an impact on the choice of monitoring strategy. Self-screening was recommended by most (71%) of the respondents. The combination of absence of symptoms and recorded AF was the definition of success for most (83%) of the respondents. Cessation of anticoagulation after ablation was an option mostly for patients with paroxysmal AF and a low CHA2DS2-VASc score. The majority of physicians perform routine monitoring after AF ablation. For most physicians, the combination of the absence of symptoms and electrocardiographic endpoints defines a successful result after AF ablation

    Statement by a Working Group conceived by the Polish National Consultants in Cardiology and Neurology addressing the use of implantable cardiac monitors in patients after ischaemic embolic stroke of undetermined source

    Get PDF
    Introduction. Stroke remains one of the main causes of death and the most common cause of long-term disability in adults. Embolic strokes of undetermined source (ESUS) amount to a significant proportion of all ischaemic strokes. Detection of atrial fibrillation (AF) in this group of patients would allow for a major therapeutic decision to switch from antiplatelets to oral anticoagulants and therefore significantly reduce the risk of recurrence. State of the Art. Current technology allows long-term continuous ECG monitoring with different systems, including implantable cardiac monitors (ICM). However, in Poland lack of reimbursement does not allow their use in everyday clinical practice. Clinical Implications. This is a statement by a Working Group conceived by the Polish National Consultants in Cardiology and Neurology addressing the use of ICM in patients after ischaemic embolic strokes of undetermined source. The aim was to develop reasonable and comprehensive guidance on how to select and manage candidates for ICM in order to obtain the maximum benefit for Polish public health. Future Directions. This expert opinion is not intended as a guideline but it provides advice as to how to optimise the potential use of ICM in patients after ESUS in the Polish setting