484 research outputs found

    Recommendation of RILEM TC237-SIB on cohesion test of recycled asphalt

    Get PDF
    This recommendation describes how to evaluate the presence of potentially active bitumen in recycled asphalt (RA) materials through the cohesion test. The experimental protocol is designed according to the research performed by the RILEM Technical Committee 237-SIB ‘‘Testing and characterization of sustainable innovative bituminous materials and systems’’ with the purpose, to develop a new, simple and fast method for the characterization of RA while limiting the need for conventional rheological tests. The guidelines in this recommendation focus on the testing procedure including specimen preparation, data analysis and provide information on the preparation of a tests report

    Rheological Behaviors of Waste Polyethylene Modified Asphalt Binder: Statistical Analysis of Interlaboratory Testing Results

    Get PDF
    This article investigated the effect of waste polyethylene (PE) on the modified asphalt binders' rheological behavior from a statistical point of view. The interlaboratory testing results from the RILEM Technical Committee 279 Valorization of Waste and Secondary Materials for Roads Task Group 1 were used for this purpose. First, an unaged 70/100 penetration graded neat binder was selected as the reference material. Next, a single 5 % content of waste PE additives (PE-pellets and PE-shreds) was mixed with a 95 % neat binder to prepare two PE modified binders. Then, dynamic shear rheometer-based temperature-frequency sweep tests were performed over a wide range of temperatures and frequencies to evaluate the rheological properties of these three binders. Different rheological behaviors were observed in the isochronal plots at high temperatures. Based on a reproducibility precision requirement proposed for phase angle, 28 degrees C was set as the transition temperature across the rheological behaviors. Next, according to the three rheological behaviors defined in a previous study by the authors, statistical analysis was introduced to identify sensitive rheological parameters and determine the thresholds. Results indicate that the phase angle measured above 28 degrees C and 1.59 Hz can be used as a sensitive parameter to discriminate the three rheological behaviors of PE modified binders. The thresholds among different behaviors were also calculated as an example for phase angle measured at the highest common testing temperature of 70 degrees C. Additional experimental evaluations on more types of PE modified binders, especially at intermediate and high temperatures, are recommended to better understand their influence on the rheological behavior of PE modified binders

    Full radius linear and nonlinear gyrokinetic simulations for tokamaks and stellarators: zonal flows, applied E x B flows, trapped electrons and finite beta

    Get PDF
    The aim of this paper is to report on recent advances made in global gyrokinetic simulations of ion temperature gradient (ITG) modes and other microinstabilities. The nonlinear development and saturation of ITG modes and the role of E x B zonal flows are studied with a global nonlinear deltaf formulation that retains parallel nonlinearity and thus allows for a check of the energy conservation property as a means of verifying the quality of the numerical simulation. Due to an optimized loading technique, the conservation property is satisfied with an unprecedented quality well into the nonlinear stage. The zonal component of the perturbation evolves to a quasi-steady state with regions of ITG suppression, strongly reduced radial energy flux and steepened effective temperature profiles alternating with regions of higher ITG mode amplitudes, larger radial energy flux and flattened effective temperature profiles. A semi-Lagrangian approach free of statistical noise is proposed as an alternative to the nonlinear deltaf formulation. An ASDEX-Upgrade experiment with an internal transport barrier is analysed with a global gyrokinetic code that includes trapped electron dynamics. The weakly destabilizing effect of trapped electron dynamics on ITG modes in an axisymmetric bumpy configuration modelling W7-X is shown in global linear simulations that retain the full electron dynamics. Finite beta effects on microinstabilities are investigated with a linear global spectral electromagnetic gyrokinetic formulation. The radial global structure of electromagnetic modes shows a resonant behaviour with rational q values

    The European Integrated Tokamak Modelling Effort:Achievements and First Physics Results

    Get PDF
    This article compares both new and commonly used boundary conditions for generating pressure-driven water flows through carbon nanotubes in molecular dynamics simulations. Three systems are considered: (1) a finite carbon nanotube membrane with streamwise periodicity and ‘gravity’-type Gaussian forcing, (2) a non-periodic finite carbon nanotube membrane with reservoir pressure control, and (3) an infinite carbon nanotube with periodicity and ‘gravity’-type uniform forcing. Comparison between these focuses on the flow behaviour, in particular the mass flow rate and pressure gradient along the carbon nanotube, as well as the radial distribution of water density inside the carbon nanotube. Similar flow behaviour is observed in both membrane systems, with the level of user input required for such simulations found to be largely dependent on the state controllers selected for use in the reservoirs. While System 1 is simple to implement in common molecular dynamics codes, System 2 is more complicated, and the selection of control parameters is less straightforward. A large pressure difference is required between the water reservoirs in these systems to compensate for large pressure losses sustained at the entrance and exit of the nanotube. Despite a simple set-up and a dramatic increase in computational efficiency, the infinite length carbon nanotube in System 3 does not account for these significant inlet and outlet effects, meaning that a much smaller pressure gradient is required to achieve a specified mass flow rate. The infinite tube set-up also restricts natural flow development along the carbon nanotube due to the explicit control of the fluid. Observation of radial density profiles suggests that this results in over-constraint of the water molecules in the tube

    Stereotactic radiosurgery for brain metastases: analysis of outcome and risk of brain radionecrosis

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>to investigate the factors affecting survival and toxicity in patients treated with stereotactic radiosurgery (SRS), with special attention to volumes of brain receiving a specific dose (V10 - V16 Gy) as predictors for brain radionecrosis.</p> <p>Patients and Methods</p> <p>Two hundred six consecutive patients with 310 cerebral metastases less than 3.5 cm were treated with SRS as primary treatment and followed prospectively at University of Rome La Sapienza Sant'Andrea Hospital. Overall survival, brain control, and local control were estimated using the Kaplan-Meier method calculated from the time of SRS. Univariate and multivariate analysis using a Cox proportional hazards regression model were performed to determine the predictive value of prognostic factors for treatment outcome and SRS-related complications.</p> <p>Results</p> <p>Median overall survival and brain control were 14.1 months and 10 months, respectively. The 1-year and 2-year survival rates were 58% and 24%, and respective brain control were 43% and 22%. Sixteen patients recurred locally after SRS, with 1-year and 2-year local control rates of 92% and 84%, respectively. On multivariate analysis, stable extracranial disease and KPS >70 were associated with the most significant survival benefit. Neurological complications were recorded in 27 (13%) patients. Severe neurological complications (RTOG Grade 3 and 4) occurred in 5.8% of patients. Brain radionecrosis occurred in 24% of treated lesions, being symptomatic in 10% and asymptomatic in 14%. On multivariate analysis, V10 through V16 Gy were independent risk factors for radionecrosis, with V10 Gy and V12 Gy being the most predictive (p = 0.0001). For V10 Gy >12.6 cm<sup>3 </sup>and V12 Gy >10.9 cm<sup>3 </sup>the risk of radionecrosis was 47%.</p> <p>Conclusions</p> <p>SRS alone represents a feasible option as initial treatment for patients with brain metastases, however a significant subset of patients may develop neurological complications. Lesions with V12 Gy >8.5 cm<sup>3 </sup>carries a risk of radionecrosis >10% and should be considered for hypofractionated stereotactic radiotherapy especially when located in/near eloquent areas.</p
    • …
    corecore