2,023 research outputs found

    PSD Estimation of Multiple Sound Sources in a Reverberant Room Using a Spherical Microphone Array

    Full text link
    We propose an efficient method to estimate source power spectral densities (PSDs) in a multi-source reverberant environment using a spherical microphone array. The proposed method utilizes the spatial correlation between the spherical harmonics (SH) coefficients of a sound field to estimate source PSDs. The use of the spatial cross-correlation of the SH coefficients allows us to employ the method in an environment with a higher number of sources compared to conventional methods. Furthermore, the orthogonality property of the SH basis functions saves the effort of designing specific beampatterns of a conventional beamformer-based method. We evaluate the performance of the algorithm with different number of sources in practical reverberant and non-reverberant rooms. We also demonstrate an application of the method by separating source signals using a conventional beamformer and a Wiener post-filter designed from the estimated PSDs.Comment: Accepted for WASPAA 201

    Peripheral fundus findings in X-linked retinoschisis

    Get PDF
    BACKGROUND/AIMS: Vitreous haemorrhage (VH) and retinal detachment (RD) cause a precipitous decline in vision in a subset of patients with X-linked retinoschisis (XLRS), an otherwise a slowly progressive condition. This study aims to report the frequency of macular and peripheral retinal findings in a large cohort of patients with XLRS and to determine whether peripheral retinal findings are associated with VH and RD. METHODS: A retrospective observational case series was performed in 65 patients with XLRS with a pathogenic variant in retinoschisin 1. Chart review included examination notes, fundus photographs and optical coherence tomography (OCT). Fisher exact tests and univariable logistic regression analysis were used to determine the association between peripheral retinal findings (including retinoschisis, metallic sheen, vascular sheathing, pigmentary changes, white spiculations and vitreous veils) and complications (including VH and RD). RESULTS: Seven eyes (8%) showed normal macular structure on OCT. Peripheral retinoschisis was significantly associated with both VH and RD. Out of 10 eyes with complications, 9 (90%) had peripheral retinoschisis, compared with 33 out of 116 eyes (28%) without complications (p=0.0014). In addition, each additional peripheral finding increased the odds of RD by a factor of 4.06 (95% CI 1.58 to 10.39, p=0.028). There were no complications in the 28 eyes with a normal periphery (p=0.84) or in the 35 eyes with metallic sheen (p=0.42). CONCLUSION: The data suggest that patients with peripheral retinoschisis are at increased risk for VH and RD. Furthermore, patients with additional peripheral retinal findings together with peripheral schisis may carry additional risk for RD

    PSD Estimation and Source Separation in a Noisy Reverberant Environment using a Spherical Microphone Array

    Get PDF
    In this paper, we propose an efficient technique for estimating individual power spectral density (PSD) components, i.e., PSD of each desired sound source as well as of noise and reverberation, in a multi-source reverberant sound scene with coherent background noise. We formulate the problem in the spherical harmonics domain to take the advantage of the inherent orthogonality of the spherical harmonics basis functions and extract the PSD components from the cross-correlation between the different sound field modes. We also investigate an implementation issue that occurs at the nulls of the Bessel functions and offer an engineering solution. The performance evaluation takes place in a practical environment with a commercial microphone array in order to measure the robustness of the proposed algorithm against all the deviations incurred in practice. We also exhibit an application of the proposed PSD estimator through a source septation algorithm and compare the performance with a contemporary method in terms of different objective measures

    Influence of Supplements on the Quality Parameters of Pleurotus sajor-caju (Fr.) Singer

    Get PDF
    Various supplements viz., Artemisia, soybean, ‘baisen’(Cicer arietinum) rice bran, apple pomace, wheat bran, ‘moong dal’ (Vigna radiate), maize flour at different concentrations (0.5, 1.0 and 1.5%) to a single base material i.e, paddy straw were evaluated for their influence on total number of flushes, average number and weight of fruit bodies and diameter of stipe and pileus. Artemisia recorded lowest average number (51.4) and highest weight (16.33g) of a fruit body. Whereas the highest average number (68.8) and lowest average weight (12.88) was registered in apple pomace. The average maximum diameter of pileus (12.33cm) was observed in Artemisia and lowest in apple pomace (10.89cm). Similarly, average maximum diameter of stipe (0.98cm) was recorded on soybean and lowest in maize flour (0.71cm).Key words: Pleurotus sajor-caju, Quality parameters, Supplements P.A. Sheikh et al. Influence of Supplements on the Quality Parameters of Pleurotus sajor-caju (Fr.) Singer. J Phytol 2/10 (2010) 60-6

    Neural network accelerator for quantum control

    Full text link
    Efficient quantum control is necessary for practical quantum computing implementations with current technologies. Conventional algorithms for determining optimal control parameters are computationally expensive, largely excluding them from use outside of the simulation. Existing hardware solutions structured as lookup tables are imprecise and costly. By designing a machine learning model to approximate the results of traditional tools, a more efficient method can be produced. Such a model can then be synthesized into a hardware accelerator for use in quantum systems. In this study, we demonstrate a machine learning algorithm for predicting optimal pulse parameters. This algorithm is lightweight enough to fit on a low-resource FPGA and perform inference with a latency of 175 ns and pipeline interval of 5 ns with  > ~>~0.99 gate fidelity. In the long term, such an accelerator could be used near quantum computing hardware where traditional computers cannot operate, enabling quantum control at a reasonable cost at low latencies without incurring large data bandwidths outside of the cryogenic environment.Comment: 7 pages, 10 figure

    Novamene: A new class of carbon allotropes

    Get PDF
    We announce a new class of carbon allotropes. The basis of this new classification resides on the concept of combining hexagonal diamond (sp3 bonded carbon - lonsdaleite) and ring carbon (sp2 bonded carbon - graphene). Since hexagonal diamond acts as an insulator and sp2 bonded rings act as conductors, these predicted materials have potential applications for transistors and other electronic components. We describe the structure of a proposed series of carbon allotropes, novamene, and carry out a detailed computational analysis of the structural and electronic properties of the simplest compound in this class: the single-ring novamene. In addition, we suggest how hundreds of different allotropes of carbon could be constructed within this class

    Quantum Control of Spin Qubits Using Nanomagnets

    Full text link
    Single-qubit gates are essential components of a universal quantum computer. Without selective addressing of individual qubits, scalable implementation of quantum algorithms is not possible. When the qubits are discrete points or regions on a lattice, the selective addressing of magnetic spin qubits at the nanoscale remains a challenge due to the difficulty of localizing and confining a classical divergence-free field to a small volume of space. Herein we propose a new technique for addressing spin qubits using voltage-control of nanoscale magnetism, exemplified by the use of voltage control of magnetic anisotropy (VCMA). We show that by tuning the frequency of the nanomagnet's electric field drive to the Larmor frequency of the spins confined to a nanoscale volume, and by modulating the phase of the drive, single-qubit quantum gates with fidelities approaching those for fault-tolerant quantum computing can be implemented. Such single-qubit gate operations have the advantage of remarkable energy efficiency, requiring only tens of femto-Joules per gate operation, and lossless, purely magnetic field control (no E-field over the target volume). Their physical realization is also straightforward using existing foundry manufacturing techniques.Comment: 10 pages, 6 figure

    Fluorophotometry as a diagnostic tool for the evaluation of dry eye disease

    Get PDF
    BACKGROUND: Dry eye disease is a common debilitating ocular disease. Current diagnostic tests used in dry eye disease are often neither sensitive nor reproducible, making it difficult to accurately diagnose and determine end points for clinical trials, or evaluate the usefulness of different medications in the treatment of dry eye disease. The recently developed fluorophotometer can objectively detect changes in the corneal epithelium by quantitatively measuring its barrier function or permeability. The purpose of the study is to investigate the use of corneal fluorescein penetration measured by the fluorophotometer as a diagnostic tool in the evaluation of dry eye patients. METHODS: Dry eye patients (16 eyes), who presented with a chief complaint of ocular irritation corresponding with dry eye, low Schirmer's one test (<10 mm after 5 minutes) and corneal fluorescein staining score of more than two, were included in the study. Normal subjects (16 eyes), who came for refraction error evaluation, served as controls. Institutional Review Board (IRB) approved consent was obtained before enrolling the subjects in the study and all questions were answered while explaining the risks, benefits and alternatives. All Fluorophotometry of the central corneal epithelium was done utilizing the Fluorotron Master (TradeMark). Each eye had a baseline fluorescein scan performed, after which 50 l of 1% sodium fluorescein dye was instilled. Three minutes later, the fluorescein was washed with 50 ml of normal saline. Fluorescein scans were then started immediately after washing and were recorded at 10, 20, 40, and 60 minutes thereafter. The corneal peak values of fluorescein concentration were recorded within the central cornea in both dry eyes and in controls. RESULTS: Ten minutes after fluorescein installition, patients with dry eye disease averaged a five-fold increase in corneal tissue fluorescein concentration (mean = 375.26 ± 202.67 ng/ml) compared with that of normal subjects (mean = 128.19 ± 85.84 ng/ml). Sixty minutes after dye installation, patients with dry eye disease still revealed higher corneal tissue fluorescein concentration (mean = 112.87 ± 52.83 ng/ml) compared with that of controls (mean = 40.64 ± 7.96 ng/ml), averaging a three-fold increase. CONCLUSION: Patients with dry eye disease demonstrated an increased corneal permeability and a slower rate of elimination to topically administered fluorescein when measured by the fluorophotometer. This suggests that fluorophotometry may serve as a valuable quantitative and objective tool for the diagnosis of dry eye disease, and in following patients' response to new treatment modalities. Fluorophotometry may serve as an objective non-invasive tool for end-point analysis in clinical trials of new treatments for dry eye disease

    Trading Pounds for Points: Engagement and Weight Loss in a Mobile Health Intervention

    Get PDF
    Abstract Objective The objective of this study was to describe participant engagement and examine predictors of weight loss and points earned through the point-based incentive system of the Social Pounds Off Digitally (POD) app. Materials and methods Overweight and obese adults with Android smartphones/tablets (body mass index 25–49.9 kg/m2; N = 24) were recruited for a 3-month weight loss intervention. Participants completed a survey assessing demographics and personality and had their weight measured. Participants received the content of the intervention via podcasts and used the Social POD app to self-monitor diet, physical activity, and weight. The Social POD app contained: tracking features; in-app notifications to track; pre-set goals for tracking; newsfeed for updates on others’ goal attainment; ability to earn and track points for usage (exchanged for study-provided prizes); and a message screen. Analyses examined relationships between percent weight loss, personality characteristics, and total points earned. Results A total of 4843 points were earned (mean = 202 ± 105 points/participant). Most participants earned all three prizes (62.5%), followed by two prizes (21%), no prizes (12.5%), and one prize (4%). Total points earned significantly predicted percent weight loss (B = −0.02, p = .01), and higher conscientiousness significantly predicted greater total points earned (B = 10.27, p = .01), but other personality characteristics assessed did not. Conclusion A mobile app yielded moderately high participant engagement, as demonstrated by points earned. Earning points was significantly associated with percent weight loss, and conscientiousness was significantly associated with total points earned. Future research should examine whether point systems impact health behavior and weight loss when rewards are discontinued. Clinical trial registration number NCT0234483
    • …
    corecore