9 research outputs found

    Conformal antenna-based wireless telemetry system for capsule endoscopy

    Get PDF
    Capsule endoscopy for imaging the gastrointestinal tract is an innovative tool for carrying out medical diagnosis and therapy. Additional modalities beyond optical imaging would enhance current capabilities at the expense of denser integration, due to the limited space available within the capsule. We therefore need new designs and technologies to increase the smartness of the capsules for a given volume. This thesis presents the design, manufacture and performance characterisation of a helical antenna placed conformally outside an endoscopic capsule, and the characterisation in-silico, in-vitro and in-vivo of the telemetry system in alive and euthanised pigs. This method does not use the internal volume of the capsule, but does use an extra coating to protect the antenna from the surrounding tissue and maintain biocompatibility for safe use inside the human body. The helical antenna, radiating at 433 MHz with a bandwidth of 20 MHz within a muscle-type tissue, presents a low gain and efficiency, which is typical for implantable and ingestible medical devices. Telemetry capsule prototypes were simulated, manufactured and assembled with the necessary internal electronics, including a commercially available transceiver unit. Thermistors were embedded into each capsule shell, to record any temperature increase in the tissue surrounding the antenna during the experiments. A temperature increase of less than 1°C was detected for the tissue surrounding the antenna. The process of coating the biocompatible insulation layer over the full length of the capsule is described in detail. Data transmission programmes were established to send programmed data packets to an external receiver. The prototypes radiated at different power levels ranging from -10 to 10 dBm, and all capsules demonstrated a satisfactory performance at a data rate of 16 kbps during phantom and in-vivo experiments. Data transmission was achieved with low bit-error rates below 10-5. A low signal strength of only -54 dBm still provided effective data transfer, irrespective of the orientation and location of the capsule, and this successfully demonstrated the feasibility of the system

    In Vivo Characterization of a Wireless Telemetry Module for a Capsule Endoscopy System Utilizing a Conformal Antenna

    Get PDF
    This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a 10 mm ×30 mm capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of –10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10−3 packet error rate and 10−5 bit error rate and no temperature increase of the tissue according to IEEE standards

    Conformal meander shaped antenna for biotelemetry in endoscopic capsules

    No full text

    Harnessing the multifunctionality in nature: a bioactive agent release system with self-antimicrobial and immunomodulatory properties

    No full text
    Major problems with biomedical devices in particular implants located in nonsterile environments concern: (i) excessive immune response to the implant, (ii) development of bacterial biofilms, and (iii) yeast and fungi infections. An original multifunctional coating that addresses all these issues concomitantly is developed. A new exponentially growing polyelectrolyte multilayer film based on polyarginine (PAR) and hyaluronic acid (HA) is designed. The films have a strong inhibitory effect on the production of inflammatory cytokines released by human primary macrophage subpopulations. This could reduce potential chronic inflammatory reaction following implantation. Next, it is shown that PAR, due to its positive charges, has an antimicrobial activity in film format against Staphylococcus aureus for 24 h. In order to have a long-term antimicrobial activity, a precursor nanoscale silver coating is deposited on the surface before adding the PAR/HA films. Moreover, the PAR/HA films can be easily further functionalized by embedding antimicrobial peptides, like catestatin (CAT), a natural host defense peptide. This PAR/HA+CAT film proves to be effective as an antimicrobial coating against yeast and fungi and its cytocompatibility is also assessed. Finally, this all-in-one system constitutes an original strategy to limit inflammation and prevents bacteria, yeast, and fungi infections