14 research outputs found

    Reconstrução do ligamento cruzado anterior com duplo feixe versus feixe único: estudo experimental

    Get PDF
    OBJECTIVE: To test an intra-articular reconstruction of the anterior cruciate ligament of the knee in 10 human cadavers by replacing 2 anterior cruciate ligament bundles, with the purpose of producing a surrogate that would be structurally more similar to the anatomy of the anterior cruciate ligament and would provide the knee with more stability. METHODS: We reconstructed the anteromedial and posterolateral bundles using a quadriceps muscle tendon graft that included a patellar bone segment. The anteromedial bundle was replaced in 10 knees (5 right and 5 left knees from different cadavers) by a quadriceps-bone tendon graft, and the anteromedial and posterolateral bundles were replaced in the matching pairs of these knees. In the latter, the bone segment was fixed to the tibia, and the tendinous portion of the graft was divided longitudinally creating two 5-mm wide bundles that were inserted individually into the femur through 2 independent bone tunnels. Then, the knees were tested mechanically to evaluate the tibial anterior dislocation in relation to the femur, as well as the rigidity of the graft. The control group was formed by the knees with intact anterior cruciate ligaments, before being resected to be reconstructed. RESULTS: The results obtained did not show superiority of double-bundle reconstruction over single-bundle reconstruction, and neither technique provided the knee with the same stability and rigidity of the intact anterior cruciate ligament. CONCLUSION: Our hypothesis, based on the anatomy and biomechanics of the knee, that reconstruction of the anterior cruciate ligament using 2 bundles would result in a more anatomic reconstruction and provide better containment of the anterior tibial translation was not supported by the results of this study.OBJETIVO: Testar uma técnica de reconstrução intra-articular do ligamento cruzado anterior do joelho em 10 cadáveres humanos com substituição de dois feixes do ligamento cruzado anterior, com objetivo de produzir um substituto estruturalmente mais semelhante à anatomia do ligamento cruzado anterior e que conferisse maior estabilidade ao joelho. MÉTODOS: Os feixes ântero-medial e póstero-lateral foram reconstruídos com um enxerto de tendão do músculo quadríceps da coxa, incluindo um segmento ósseo patelar. Dez joelhos (cinco direitos e cinco esquerdos de cadáveres diferentes) tiveram o feixe ântero-medial substituído por um enxerto de tendão quadricipital-osso e, nos pares desses joelhos, foram substituídos o feixe ântero-medial e o póstero-lateral. Nestes últimos, o segmento ósseo foi fixado na tíbia e a parte tendinosa do enxerto foi dividida longitudinalmente, dando origem a dois feixes de 5 mm de largura, que foram inseridos separadamente no fêmur através de dois túneis ósseos independentes. Os joelhos foram então submetidos a ensaios mecânicos, nos quais avaliamos o deslocamento anterior da tíbia em relação ao fêmur e a rigidez do enxerto. Os joelhos com ligamento cruzado anterior íntegro, antes de sua ressecção para a realização das reconstruções, formaram o grupo controle. RESULTADOS: Os resultados obtidos não mostraram superioridade da reconstrução com duplo feixe sobre a reconstrução com feixe único e nenhuma delas conferiu ao joelho a mesma estabilidade e rigidez do ligamento cruzado anterior íntegro. CONCLUSÃO: Apesar de encontrarmos na anatomia e na biomecânica do joelho razões para procurarmos reconstruir o ligamento cruzado anterior com dois feixes, no intuito de tornar a sua reconstrução mais anatômica, proporcionando uma melhor contenção da translação anterior da tíbia, não conseguimos, com os nossos resultados, justificar a utilização da técnica estudada

    Posicionamento do túnel femoral na reconstrução artroscópica do LCA: estudo comparativo de duas técnicas

    Get PDF
    OBJECTIVE: To compare the accuracy of positioning of the femoral tunnel in reconstructing the anterior cruciate ligament by means of 2 techniques: tibial tunnel and anteromedial portal. METHOD: Femoral tunnels were drilled in 20 knees from human cadavers by means of arthroscopy. Group I had the femoral tunnel drilled via a trans-tibial tunnel, and Group II via the anteromedial portal. Four variables were measured: A) posterior wall thickness; B) tunnel positioning at the notch; C) tunnel inclination in relation to the femoral axis; and D) distance between the wire guide exit and the lateral epicondyle. RESULTS: As above, respectively, A) 2.23 mm for group I and 2.36 mm for group II (P =.54); B) 25.5° for group I and 30.0° for group II (P =.23); C) 23.9° for group I and 32.0° for group II (P =.02); D) 7.8 cm for group I and 3.9 cm for group II (POBJETIVO: Comparar a acurácia do posicionamento do túnel femoral na reconstrução do ligamento cruzado anterior através de duas vias: túnel tibial e portal ântero - medial. MÉTODO: Foram perfurados túneis femorais em vinte joelhos de cadáveres humanos por via artroscópica. Grupo I: túnel femoral por acesso trans túnel tibial. Grupo II: via portal ântero-medial. Quatro variáveis foram estudadas: A) espessura da parede posterior; B) posicionamento do túnel no intercôndilo; C) angulação do túnel em relação ao eixo do fêmur; D) distância entre a saída do fio guia e o epicôndilo lateral. RESULTADO: A) grupo I: 2,23 mm, grupo II: 2,36 mm (p=0,543); B) grupo I: 25,5º, grupo II: 30º (p=0,226); C) grupo I: 23,9º, grupo II: 32º (p= 0,014); D) grupo I: 7,8 cm, grupo II 3,9 cm (

    Surgery computer assisted, Anterior cruciate ligament/surgery, Comparative study, Cadaver, Knee/surgery, Arthroscopy

    No full text
    INTRODUÇÃO: A precisão no posicionamento dos túneis ósseos na reconstrução do ligamento cruzado anterior do joelho (LCA) é considerado um dos fatores fundamentais para o bom resultado dessa cirurgia. A cirurgia ortopédica auxiliada por computador (computer aided orthopedic surgery CAOS) é um avanço tecnológico que tem como um dos principais objetivos exatamente o aumento da precisão. OBJETIVO: comparar o posicionamento do centro dos túneis e a isometria do enxerto obtidos com o uso de um sistema de navegação computadorizada (Orthopilot) e com o uso de guias cirúrgicos convencionais. MÉTODOS: 36 joelhos pareados de cadáveres tiveram o LCA ressecado por artroscopia no Laboratório de Artroscopia do Departamento de Ortopedia e Traumatologia da Faculdade de Medicina da Universidade de São Paulo. Um joelho de cada par foi ramdomizado para o grupo 1 (guias cirúrgicos convencionais) e o outro para o grupo 2 (Orthopilot). Um fio de sutura inelástico foi passado pelo centro dos túneis tibial e femoral confeccionados para a reconstrução do LCA, sem que os túneis fossem finalmente brocados. Todos os joelhos foram então analisados quanto ao posicionamento do centro do túnel tibial (distância do LCP, distância da tubérculo intercondilar medial da tíbia e distância do corno anterior do menisco lateral), do centro do túnel femoral (distância da cortical posterior e angulação coronal na fossa intercondilar do fêmur) e a variação da distância entre os pontos centrais do túnel femoral para o túnel tibial em flexão de 90º e em extensão (isometria). Os dados foram analisados segundo o teste de Wilcoxon para comparação de duas amostras pareadas. RESULTADOS: A variação da distância entre o tunel femoral e tibial em flexão e extensão (isometria) foi maior no grupo 1 convencional, do que no grupo 2 Orthopilot (grupo 1: média 4,2mm com intervalo de 1,1mm a 9,4mm versus grupo 2: média 2,8mm com intervalo de 0,3mm a 6,7mm; p<0,05). Os outros parâmetros analisados não tiveram diferença estatística entre os grupos e demonstraram que todos os túneis dos dois grupos estavam bem posicionados de acordo com os critérios adotados. CONCLUSÕES: O emprego de instrumental cirúrgico navegado pelo sistema Orhtopilot permitiu o posicionamento dos túneis ósseos da reconstrução do LCA de maneira tão precisa quanto os guias cirúrgicos convencionais utilizados. Mais do que isso, proporcionou um posicionamento significativamente mais isométrico nessa sérieINTRODUCTION: Precise tunnel location has been considered to be very important to achieve good results in anterior cruciate ligament (ACL) reconstruction surgery. Computer Aided Orthopedic Surgery (CAOS) is a technology improvement whose main objective is to enhance precision. PURPOSE: To compare the accuracy of tunnel placement and graft isometry for ACL reconstruction performed with the use of a computer-assisted navigation system (Orthopilot) and with traditional instruments. METHODS: 36 matched-paired cadaveric knees had their intact ACL removed by arthroscopy at the Arthroscopy Laboratory Orthopedic Department of University of São Paulo Medical School. One knee of each pair was randomized to group 1 (traditional instruments) or group 2 (Orthopilot). An inelastic suture was then passed through the center of where would be the tibial tunnel and then through the center of where would be the femoral tunnel. None of the tunnels were actually drilled. All knees were then dissected and 6 parameters were obtained: The distance from the tibial tunnel center to: 1) the PCL; 2) the lateral meniscus anterior horn; 3) the medial tibial spine. 4) The distance from the femoral tunnel center to the posterior femoral cortex. 5) The femoral tunnel coronal angle. 6) The variation of the distance from the femoral to the tibial tunnels with the knee extended and in 90 degree flexion. The data were submitted to statistical analysis and compared with the Wilcoxon Matched Pairs Test. RESULTS: The variation of the distance from the femoral to the tibial tunnels in flexion and extension was smaller in the Orthopilot group (better isometry): group 1: mean 4.2 mm (1.1-9.4 mm); group 2: mean 2.8 mm (0.3-6.7 mm) p<0,05. All other parameters showed no statistical difference between the groups and all tunnels were considered to be in satisfactory positions. DISCUSSION: There was no difference in tunnel position between the groups. Better isometry was achieved in the Orthopilot group compared to conventional instrument

    Articuled external fixator for treatment of the chronic multiple ligament-injured knee

    No full text
    INTRODUÇÃO: A instabilidade multiligamentar do joelho, normalmente, é provocada por um trauma que determina sua luxação, um evento pouco frequente, mas, que pode trazer sequelas devastadoras. Mesmo com o tratamento cirúrgico preconizado é alto o índice de complicações. A mobilização precoce no pósoperatório provoca afrouxamento dos ligamentos reconstruídos, o que leva à instabilidade residual. A imobilização melhora a estabilidade, mas provoca dor e rigidez. Este trabalho tem o objetivo de avaliar se o uso do fixador externo articulado proporciona melhora na mobilidade, estabilidade e na função subjetiva de pacientes submetidos à reconstrução ligamentar. MÉTODOS: Neste ensaio clínico randomizado com grupos paralelos, 33 pacientes do ambulatório do Instituto de Ortopedia e Traumatologia do Hospital das Clínicas da Universidade de São Paulo com mais que 3 semanas de lesão dos ligamentos cruzados anterior e posterior associado à lesão de ligamento colateral fibular e/ ou ligamento colateral tibial foram submetidos à cirurgia de reconstrução multiligamentar, após alocação cega aleatória ao grupo 0 - controle (18 pacientes), com órtese rígida ou ao grupo 1 - fixador externo articulado por 6 semanas (15 pacientes), no período entre novembro de 2010 e novembro de 2013. Após seguimento mínimo de um ano de pós-operatório, a estabilidade dos ligamentos reconstruídos foi avaliada ao exame físico, foram mensurados os déficits de extensão e de flexão residual em relação ao joelho contralateral não acometido e foi aplicado o questionário específico para sintomas do joelho de Lysholm. RESULTADOS: Não houve diferença na avaliação da estabilidade articular nem na extensão entre os grupos. No grupo 1, o déficit de flexão passiva foi menor (4,8º +- 5,4º contra 18,2 +- 14,8º, p < 0,05) com mais pacientes, obtendo déficit de flexão considerado normal, de até 5º (64% contra 18%, p < 0,05) e com classificação excelente ou boa no questionário de Lysholm (73% contra 35%, p < 0,05). CONCLUSÕES: Comparado ao protocolo de reabilitação com órtese rígida removível, o uso do fixador externo articulado no tratamento cirúrgico das lesões multiligamentares do joelho proporciona os mesmos resultados de estabilidade ligamentar, aumenta a amplitude de movimento final, com manutenção da extensão e redução do déficit de flexão e proporciona melhores resultados funcionaisINTRODUCTION: Multiligament knee instability is normally caused by a trauma which results in its dislocation, an infrequent event, but one which can have devastating aftereffects. Even with the recommended surgical treatment the rate of complications is high. Early post-operative mobilization provokes loosening of the reconstructed ligaments, which leads to residual instability. Immobilization improves the stability, but causes pain and stiffness. This study aims to assess whether the use of an articulated external fixator provides improvements in the mobility, stability and the subjective function of the patients submitted to ligament reconstruction. METHODS: In this randomized clinical trial with parallel groups, 33 patients of the outpatient clinic of the Institute of Orthopaedics and Traumatology of the Hospital das Clínicas of the University of Sao Paulo with more than 3 weeks of injury to the anterior cruciate ligaments and the posterior cruciate ligaments associated with injury to the fibular collateral ligament and/or medial collateral ligament, were submitted to multiligament reconstruction surgery, after blind random allocation to either: Group 0 - control (18 patients), with rigid bracing, or to Group 1 - articulated external fixator for 6 weeks (15 patients), in the period from November, 2010 to November 2013. The stability of the reconstructed ligaments were assessed after 1 year postoperatively by physical examination, the deficit of residual extension and flexion was measured in relation to the unaffected contralateral knee and the Lysholm knee scoring scale questionnaire was applied. RESULTS: There was no difference in the assessment of joint stability or of the extension between the groups. In group 1 the passive flexion deficit was less (4.8º +- 5.4º versus 18.2 +- 14.8º, p<0.05) with more patients obtaining a flexion deficit considered normal, or up to 5º (64% versus 18%, p<0.05) and with excellent or good classification in the Lysholm knee scoring scale questionnaire (73% versus 35%, p<0.05). CONCLUSIONS: Compared to the rehabilitation protocol with removable rigid bracing, the use of an articulated external fixator in the treatment of multiligament knee injuries provides equal results for ligament stability, increases the amplitude of the Range of Motion, maintains the extension and reduces the flexion deficit, and provides better functional resul

    Anterior cruciate ligament reconstruction with double bundle versus single bundle: experimental study

    No full text
    OBJECTIVE: To test an intra-articular reconstruction of the anterior cruciate ligament of the knee in 10 human cadavers by replacing 2 anterior cruciate ligament bundles, with the purpose of producing a surrogate that would be structurally more similar to the anatomy of the anterior cruciate ligament and would provide the knee with more stability. METHODS: We reconstructed the anteromedial and posterolateral bundles using a quadriceps muscle tendon graft that included a patellar bone segment. The anteromedial bundle was replaced in 10 knees (5 right and 5 left knees from different cadavers) by a quadriceps-bone tendon graft, and the anteromedial and posterolateral bundles were replaced in the matching pairs of these knees. In the latter, the bone segment was fixed to the tibia, and the tendinous portion of the graft was divided longitudinally creating two 5-mm wide bundles that were inserted individually into the femur through 2 independent bone tunnels. Then, the knees were tested mechanically to evaluate the tibial anterior dislocation in relation to the femur, as well as the rigidity of the graft. The control group was formed by the knees with intact anterior cruciate ligaments, before being resected to be reconstructed. RESULTS: The results obtained did not show superiority of double-bundle reconstruction over single-bundle reconstruction, and neither technique provided the knee with the same stability and rigidity of the intact anterior cruciate ligament. CONCLUSION: Our hypothesis, based on the anatomy and biomechanics of the knee, that reconstruction of the anterior cruciate ligament using 2 bundles would result in a more anatomic reconstruction and provide better containment of the anterior tibial translation was not supported by the results of this study.OBJETIVO: Testar uma técnica de reconstrução intra-articular do ligamento cruzado anterior do joelho em 10 cadáveres humanos com substituição de dois feixes do ligamento cruzado anterior, com objetivo de produzir um substituto estruturalmente mais semelhante à anatomia do ligamento cruzado anterior e que conferisse maior estabilidade ao joelho. MÉTODOS: Os feixes ântero-medial e póstero-lateral foram reconstruídos com um enxerto de tendão do músculo quadríceps da coxa, incluindo um segmento ósseo patelar. Dez joelhos (cinco direitos e cinco esquerdos de cadáveres diferentes) tiveram o feixe ântero-medial substituído por um enxerto de tendão quadricipital-osso e, nos pares desses joelhos, foram substituídos o feixe ântero-medial e o póstero-lateral. Nestes últimos, o segmento ósseo foi fixado na tíbia e a parte tendinosa do enxerto foi dividida longitudinalmente, dando origem a dois feixes de 5 mm de largura, que foram inseridos separadamente no fêmur através de dois túneis ósseos independentes. Os joelhos foram então submetidos a ensaios mecânicos, nos quais avaliamos o deslocamento anterior da tíbia em relação ao fêmur e a rigidez do enxerto. Os joelhos com ligamento cruzado anterior íntegro, antes de sua ressecção para a realização das reconstruções, formaram o grupo controle. RESULTADOS: Os resultados obtidos não mostraram superioridade da reconstrução com duplo feixe sobre a reconstrução com feixe único e nenhuma delas conferiu ao joelho a mesma estabilidade e rigidez do ligamento cruzado anterior íntegro. CONCLUSÃO: Apesar de encontrarmos na anatomia e na biomecânica do joelho razões para procurarmos reconstruir o ligamento cruzado anterior com dois feixes, no intuito de tornar a sua reconstrução mais anatômica, proporcionando uma melhor contenção da translação anterior da tíbia, não conseguimos, com os nossos resultados, justificar a utilização da técnica estudada

    Positioning of the femoral tunnel for arthroscopic reconstruction of the anterior cruciate ligament: comparative study of 2 techniques Posicionamento do túnel femoral na reconstrução artroscópica do LCA: estudo comparativo de duas técnicas

    Get PDF
    OBJECTIVE: To compare the accuracy of positioning of the femoral tunnel in reconstructing the anterior cruciate ligament by means of 2 techniques: tibial tunnel and anteromedial portal. METHOD: Femoral tunnels were drilled in 20 knees from human cadavers by means of arthroscopy. Group I had the femoral tunnel drilled via a trans-tibial tunnel, and Group II via the anteromedial portal. Four variables were measured: A) posterior wall thickness; B) tunnel positioning at the notch; C) tunnel inclination in relation to the femoral axis; and D) distance between the wire guide exit and the lateral epicondyle. RESULTS: As above, respectively, A) 2.23 mm for group I and 2.36 mm for group II (P =.54); B) 25.5&deg; for group I and 30.0&deg; for group II (P =.23); C) 23.9&deg; for group I and 32.0&deg; for group II (P =.02); D) 7.8 cm for group I and 3.9 cm for group II (P <.001). CONCLUSIONS: Both techniques achieved the desired positioning for the femoral tunnel entrance and satisfactory thickness for the posterior cortex. Drilling via the anteromedial portal may provide greater protection against rupture of the posterior wall.<br>OBJETIVO: Comparar a acurácia do posicionamento do túnel femoral na reconstrução do ligamento cruzado anterior através de duas vias: túnel tibial e portal ântero - medial. MÉTODO: Foram perfurados túneis femorais em vinte joelhos de cadáveres humanos por via artroscópica. Grupo I: túnel femoral por acesso trans túnel tibial. Grupo II: via portal ântero-medial. Quatro variáveis foram estudadas: A) espessura da parede posterior; B) posicionamento do túnel no intercôndilo; C) angulação do túnel em relação ao eixo do fêmur; D) distância entre a saída do fio guia e o epicôndilo lateral. RESULTADO: A) grupo I: 2,23 mm, grupo II: 2,36 mm (p=0,543); B) grupo I: 25,5º, grupo II: 30º (p=0,226); C) grupo I: 23,9º, grupo II: 32º (p= 0,014); D) grupo I: 7,8 cm, grupo II 3,9 cm (p<0,001). CONCLUSÃO: As duas técnicas obteveram o posicionamento desejado da entrada do túnel femoral e espessura adequada da cortical posterior. A perfuração via portal ântero-medial pode propiciar maior proteção contra rotura da parede posterior

    Extra-articular and transcutaneous migration of the poly-l/D-lactide interference screw after popliteal tendon reconstruction

    No full text
    ABSTRACT Knee ligament reconstructions are commonly performed orthopedic procedures. Graft fixation is generally performed with metallic or absorbable interference screws. In a recent study, only ten reports of screw migration were retrieved; of these, only one was not related to the anterior cruciate ligament, and the majority was related to the use of poly-l-lactic acid (PLLA) screws. Only one case retrieved in the literature reported screw migration in reconstructions of the posterolateral corner, and that was to the intra-articular region. In the present article, the authors report a case of extra-articular and transcutaneous migration of a poly-l/D-lactide (PDLLA) interference screw following popliteal tendon reconstruction. Besides being the first case of popliteal tendon migration with extra-articular screw migration, no reports of PDLLA screw migration were retrieved in the literature

    Judet quadricepsplasty in the treatment of posttraumatic knee rigidity: Long-term outcomes of 45 cases

    No full text
    BACKGROUND: Posttraumatic knee stiffness is a very debilitating condition. Judet's quadricepsplasty technique has been used for more than 50 years. However, few reports of quadricepsplasty results exist in the literature. METHODS: We report the results of 45 cases of posttraumatic arthrofibrosis of the knee treated with Judet's quadricepsplasty. The results of the procedure were analyzed by measuring the degrees of flexion of the operated knees at different time points (before, immediately after, and late postoperatively). RESULTS: The degree of flexion increased from 33.6 degrees (range, 5-80 degrees) preoperatively to 105 degrees (range, 45-160 degrees) immediately after surgery, followed by a slight fall in the range of motion (ROM) in the late postoperative period, which reached an average of 84.8 degrees. There was no significant correlation between knee strength and the patient's gender, but there was a slight trend of lower strength with age. Although Judet's quadricepsplasty technique dates from more than 50 years ago, it still provides good outcomes in the treatment of rigid knees of various etiologies. In general, all cases showed the same pattern of a small decrease in the ROM in the late postoperative period. CONCLUSION: Judet's quadricepsplasty can increase the ROM of rigid knees. The ROM obtained with the surgery persists long term. (J Trauma. 2012; 72: E77-E80. Copyright (C) 2012 by Lippincott Williams & Wilkins

    Anatomical study on the anterolateral ligament of the knee

    Get PDF
    OBJECTIVE: Describe the knee anterolateral ligament (ALL) and establish its anatomical marks of origin and insertion. METHODS: Dissection of the anterolateral aspect of the knee was performed in six cadavers. After isolation of the ALL, its lenght, width and thickness were measured as its places of origin and insertion. The ALL origin was documented in relation to the lateral collateral ligament (LCL) origin and the insertion was documented in relation to the Gerdy tubercle, fibullar head and lateral meniscus. After the first two dissections, the ligament was removed and sent to histologycal analysis. RESULTS: The ALL was clearly identified in all knees. Its origin in the lateral epycondile was on average 0.5 mm distal and 2.5 mm anterior to the LCL. In the tibia, two insertions were observed, one in the lateral meniscus and another in the proximal tibia, about 4.5 mm distal to the articular cartilage, between the Gerdy tubercle and the fibullar head. The average measures obtained were: 35.1 mm lenght, 6.8 mm width and 2.6 mm thickness. In the ligament histological analysis, dense connective tissue was observed. CONCLUSION: The ALL is a constant structure in the knee anterolateral region. Its origin is anterior and distal to the LCL origin. In the tibia, it has two insertions, one in the lateral meniscus and another in the proximal tibia between the Gerdy tubercle and the fibullar head
    corecore