26 research outputs found

    Identification of gunshot residue: a critical review.

    No full text
    A review of the scientific papers published on inorganic gunshot residue (GSR) analysis permits to study how the particle analysis has shown its capability in detection and identification of gunshot residue. The scanning electron microscope can be the most powerful tool for forensic scientists to determine the proximity to a discharging firearm and/or the contact with a surface exposed to GSR. Particle analysis can identify individual gunshot residue particles through both morphological and elemental characteristics. When particles are detected on the collected sample, the analytical results can be interpreted following rules of a formal general interpretative system, to determine whether they come from the explosion of a primer or from other possible sources. The particles on the sample are compared with an abstract idea of “unique” GSR particle produced by the sole source of the explosion of a primer. “Uniqueness” is not the only problem related to GSR detection and identification for a forensic scientist. With “not-unique” particles interpretation of results is extremely important. The evidential strength of “not-unique” particles can increase with a more fruitful interpretative framework based on Bayes rule. For the assessment of the value of a GSR in linking a suspect and a crime, it is important to compare two hypothesis: the first can be that of the evidence if the suspect has been shooting in a specific situation, the second that of the evidence if the suspect was not involved in this shooting. This case specific or case-by-case approach is closer to what the court is interested in. The authors consider that a “case-by-case” approach should be followed whenever possible. Research of models and data such as those developed in other trace evidence material (fibres, glass, etc.) using a Bayesian approach is suggested in the interpretation of GSR

    Multiclass analysis of illicit drugs in plasma and oral fluids by LC-MS/MS

    No full text
    An analytical procedure for the simultaneous determination in human plasma and oral fluids of several illicit drugs belonging to different chemical and toxicological classes is presented. Amphetamine, methamphetamine, morphine, 6-monoacetylmorphine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethamphetamine, cocaine, benzoylecgonine, tetrahydrocannabinol, carboxytetrahydrocannabinol, ketamine, and phencyclidine have been quantified in real samples using a very rapid sample treatment, basically a protein precipitation. The quantitative analysis was performed by liquid chromatography-tandem mass spectrometry and has been fully validated. All the analytes were detected in positive ionization mode using a source, except carboxytetrahydrocannabinol, which was detected in negative ionization mode. The use of a diverter valve between the column and the mass spectrometer allows the preservation of the ion source performances for high-throughput analysis.[...

    Accidental death involving professional fireworks

    No full text
    An interesting case of accidental death involving the explosion of professional fireworks in an apartment is described. The examination of the scene permitted to study several effects of the explosion on walls, ceiling, furniture and especially on a balcony where the victim was found. The external examination of the victim showed extensive thermal injuries, degloving injuries and extensive shrapnel wounds. The autopsy examination showed subarachnoid haemorrhage localized to the cerebellum, haemorrhage in the soft tissues of the neck and chest and fracture of one clavicle. Almost the entire surface of lungs showed blunt injuries and the liver showed tearing of parenchyma and multiple cavities. Histological analysis were carried out showing thickening of alveolar septae, enlargement of alveolar spaces and alveolar ruptures in lung sections while numerous, round, empty spaces were detected in the parenchyma of the liver. The examination of the scene and of the fragments found showed that at least eight pyrotechnical charges exploded on the balcony, in close proximity of the threshold with the living room of the apartment. According to the chemical findings, the charges were typical for professional use and were filled with a mixture of potassium perchlorate and aluminium. A conservative calculation results in more than 1.5 kg total mass of pyrotechnic composition exploding very close to the victim

    Correlazione tra dosaggio plasmatico e salivare del Levetiracetam in pazienti con Epilessia.

    No full text

    High-throughput screening for new psychoactive substances (NPS) in whole blood by DLLME extraction and UHPLC-MS/MS analysis

    No full text
    The increasing number of new psychoactive substances (NPS) present in the illicit market render their identification in biological fluids/tissues of great concern for clinical and forensic toxicology. Analytical methods able to detect the huge number of substances that can be used are sought, considering also that many NPS are not detected by the standard immunoassays generally used for routine drug screening. The aim of this work was to develop a method for the screening of different classes of NPS (a total of 78 analytes including cathinones, synthetic cannabinoids, phenethylamines, piperazines, ketamine and analogues, benzofurans, tryptamines) from blood samples. The simultaneous extraction of analytes was performed by Dispersive Liquid/Liquid Microextraction DLLME, a very rapid, cheap and efficient extraction technique that employs microliters amounts of organic solvents. Analyses were performed by a target Ultrahigh Performance Liquid Chromatography tandem Mass Spectrometry (UHPLC-MS/MS) method in multiple reaction monitoring (MRM). The method allowed the detection of the studied analytes with limits of detection (LODs) ranging from 0.2 to 2ng/mL. The proposed DLLME method can be used as an alternative to classical liquid/liquid or solid-phase extraction techniques due to its rapidity, necessity to use only microliters amounts of organic solvents, cheapness, and to its ability to extract simultaneously a huge number of analytes also from different chemical classes. The method was then applied to 60 authentic real samples from forensic cases, demonstrating its suitability for the screening of a wide number of NPS

    Ultra high performance liquid chromatography\u2013electrospray ionization\u2013tandem mass spectrometry screening method for direct analysis of designer drugs, \u201cspice\u201d and stimulants in oral fluid

    No full text
    An ultra high performance liquid chromatography\u2013electrospray ionization\u2013tandem mass spectrometry (UHPLC\u2013ESI\u2013MS/MS) screening method for the direct analysis in oral fluid (OF) of 24 drugs, including new synthetic cannabinoids and so-called \u201csmart\u201d designer drugs, in a single chromatographic run was set up. Benzylpiperazine, methylone, 5,6-methylenedioxy-2-aminoindane (MDAI), fenproporex, 4-fluoroamphetamine (4-FA), 4-methyl-N-ethylcathinone (4-MEC), 4-methylamphetamine (4-MA), methylbenzodioxolylbutanamine (MBDB), mephedrone, methylthioamphetamine (MTA), methylenedioxypyrovalerone (MDPV), mefenorex, nabilone, furfenorex, clobenzorex, JWH-200, AM 694, JWH-250, JWH-073, JWH-018, JWH-019, JWH-122, HU 210 and CP 47497 were determined in a chromatographic run of 9 min only with no sample pre-treatment, after addition of ISs and dilution in mobile phase A. This method is designed to be applied to 250 L of OF sample, anyway is suitable to be used on smaller volumes (till 100 L). LODs vary from 1 ng/mL to 20 ng/mL. No interfering peaks were observed due to similar analytes, common therapeutic drugs or endogenous compounds. Matrix effect, although present especially for mephedrone, is acceptable, allowing the detection of the compounds at the LODs described. The developed method was applied on 400 real OF samples from on-site tests performed by police officers

    Saliva and serum levetiracetam concentrations in patients with epilepsy

    No full text
    Although antiepileptic drug (AED) monitoring in saliva may have some clinical applicability, it has not yet come into routine use. The correlation between levetiracetam (LEV) saliva and serum concentrations also remains unclear. To confirm LEV saliva assay as a useful, noninvasive alternative to serum measurement, we investigated the possible correlation between saliva and serum LEV concentrations. Samples of saliva and blood were collected from 30 patients with epilepsy receiving chronic therapy with LEV as monotherapy or add-on therapy, and LEV concentrations were assayed in saliva and serum. Linear regression analyses showed a close correlation between saliva and serum LEV concentrations (r = 0.90; P < 0.001). LEV blood and saliva concentrations were linearly related to daily drug doses (r = 0.78 and 0.70; P < 0.01). When data were analyzed for subgroups (patients receiving LEV in monotherapy, as add-on therapy with enzyme-inducer AEDs, and as add-on therapy with noninducer or moderate-inducer AEDs), no significant difference was found between saliva and serum LEV concentrations among groups. These preliminary results indicate that LEV, like other AEDs, can be measured in saliva as an alternative to blood-based assays. Saliva LEV collection and assay is a valid noninvasive, more convenient alternative to serum measurement. © 2007 Lippincott Williams & Wilkins, Inc
    corecore