29 research outputs found

    Cytochrome-P450 enzymes and autoimmunity: expansion of the relationship and introduction of free radicals as the link

    Get PDF
    The Cytochrome-P-450 enzymes (CYP) are among the most important xenobiotic-metabolizing enzymes, which produce reactive oxygen species (ROS) as the result of metabolizing xenobiotics

    Patient-Specific Computational Modeling of Upper Extremity Arteriovenous Fistula Creation: Its Feasibility to Support Clinical Decision-Making

    Get PDF
    <div><h3>Introduction</h3><p>Inadequate flow enhancement on the one hand, and excessive flow enhancement on the other hand, remain frequent complications of arteriovenous fistula (AVF) creation, and hamper hemodialysis therapy in patients with end-stage renal disease. In an effort to reduce these, a patient-specific computational model, capable of predicting postoperative flow, has been developed. The purpose of this study was to determine the accuracy of the patient-specific model and to investigate its feasibility to support decision-making in AVF surgery.</p> <h3>Methods</h3><p>Patient-specific pulse wave propagation models were created for 25 patients awaiting AVF creation. Model input parameters were obtained from clinical measurements and literature. For every patient, a radiocephalic AVF, a brachiocephalic AVF, and a brachiobasilic AVF configuration were simulated and analyzed for their postoperative flow. The most distal configuration with a predicted flow between 400 and 1500 ml/min was considered the preferred location for AVF surgery. The suggestion of the model was compared to the choice of an experienced vascular surgeon. Furthermore, predicted flows were compared to measured postoperative flows.</p> <h3>Results</h3><p>Taken into account the confidence interval (25<sup>th</sup> and 75<sup>th</sup> percentile interval), overlap between predicted and measured postoperative flows was observed in 70% of the patients. Differentiation between upper and lower arm configuration was similar in 76% of the patients, whereas discrimination between two upper arm AVF configurations was more difficult. In 3 patients the surgeon created an upper arm AVF, while model based predictions allowed for lower arm AVF creation, thereby preserving proximal vessels. In one patient early thrombosis in a radiocephalic AVF was observed which might have been indicated by the low predicted postoperative flow.</p> <h3>Conclusions</h3><p>Postoperative flow can be predicted relatively accurately for multiple AVF configurations by using computational modeling. This model may therefore be considered a valuable additional tool in the preoperative work-up of patients awaiting AVF creation.</p> </div

    Coronary microvascular resistance: methods for its quantification in humans

    Get PDF
    Coronary microvascular dysfunction is a topic that has recently gained considerable interest in the medical community owing to the growing awareness that microvascular dysfunction occurs in a number of myocardial disease states and has important prognostic implications. With this growing awareness, comes the desire to accurately assess the functional capacity of the coronary microcirculation for diagnostic purposes as well as to monitor the effects of therapeutic interventions that are targeted at reversing the extent of coronary microvascular dysfunction. Measurements of coronary microvascular resistance play a pivotal role in achieving that goal and several invasive and noninvasive methods have been developed for its quantification. This review is intended to provide an update pertaining to the methodology of these different imaging techniques, including the discussion of their strengths and weaknesses

    Signal One and Two Blockade Are Both Critical for Non-Myeloablative Murine HSCT across a Major Histocompatibility Complex Barrier

    Get PDF
    Non-myeloablative allogeneic haematopoietic stem cell transplantation (HSCT) is rarely achievable clinically, except where donor cells have selective advantages. Murine non-myeloablative conditioning regimens have limited clinical success, partly through use of clinically unachievable cell doses or strain combinations permitting allograft acceptance using immunosuppression alone. We found that reducing busulfan conditioning in murine syngeneic HSCT, increases bone marrow (BM):blood SDF-1 ratio and total donor cells homing to BM, but reduces the proportion of donor cells engrafting. Despite this, syngeneic engraftment is achievable with non-myeloablative busulfan (25 mg/kg) and higher cell doses induce increased chimerism. Therefore we investigated regimens promoting initial donor cell engraftment in the major histocompatibility complex barrier mismatched CBA to C57BL/6 allo-transplant model. This requires full myeloablation and immunosuppression with non-depleting anti-CD4/CD8 blocking antibodies to achieve engraftment of low cell doses, and rejects with reduced intensity conditioning (≤75 mg/kg busulfan). We compared increased antibody treatment, G-CSF, niche disruption and high cell dose, using reduced intensity busulfan and CD4/8 blockade in this model. Most treatments increased initial donor engraftment, but only addition of co-stimulatory blockade permitted long-term engraftment with reduced intensity or non-myeloablative conditioning, suggesting that signal 1 and 2 T-cell blockade is more important than early BM niche engraftment for transplant success

    ECE system on ASDEX-upgrade placed inline at the high power waveguide based transmission system

    Get PDF
    It is proposed to provide the Electron Cyclotron Emission (ECE) feedback signal for MHD control experiments along the ECRH line-of sight. Experiments on TEXTOR have demonstrated a proof of principle [1], [2] and [3] motivate the further development and the implementation of such an ECCD aligned ECE system for NTM control in larger fusion machines. Implementation of such a system on ASDEX-Upgrade [4], based on waveguides equipped with a fast directional switch, is presented in this paper [6]. First results of open loop control of MHD modes in TEXTOR were presented in [2, 7]. © 2009 IEEE

    A guinea pig model of acute and chronic asthma using permanently instrumented and unrestrained animals

    No full text
    To investigate mechanisms underlying allergen-induced asthmatic reactions, airway hyperresponsiveness and remodeling, we have developed a guinea pig model of acute and chronic asthma using unanesthetized, unrestrained animals. To measure airway function, ovalbumin (IgE)-sensitized animals are permanently instrumented with a balloon-catheter, which is implanted inside the pleural cavity and exposed at the neck of the animal. Via an external cannula, the balloon-catheter is connected to a pressure transducer, an amplifier, an A/D converter and a computer system, enabling on-line measurement of pleural pressure (P(pl))-closely correlating with airway resistance-for prolonged periods of time. Using aerosol inhalations, the method has been successfully applied to measure ovalbumin-induced early and late asthmatic reactions and airway hyperresponsiveness. Because airway function can be monitored repeatedly, intra-individual comparisons of airway responses (e. g., to study drug effects) are feasible. Moreover, this model is suitable to investigate chronic asthma and airway remodeling, which occurs after repeated allergen challenges. The protocol for establishing this model takes about 4 weeks
    corecore