3 research outputs found

    Minimal Invasive Ostheosintesis For Treatment Of Diaphiseal Transverse Humeral Shaft Fractures

    Get PDF
    Objective: To evaluate patients with transverse fractures of the shaft of the humerus treated with indirect reduction and internal fixation with plate and screws through minimally invasive technique. Methods: Inclusion criteria were adult patients with transverse diaphyseal fractures of the humerus closed, isolated or not occurring within 15 days of the initial trauma. Exclusion criteria were patients with compound fractures. Results: In two patients, proximal screw loosening occurred, however, the fractures consolidated in the same mean time as the rest of the series. Consolidation with up to 5 degrees of varus occurred in five cases and extension deficit was observed in the patient with olecranon fracture treated with tension band, which was not considered as a complication. There was no recurrence of infection or iatrogenic radial nerve injury. Conclusion: It can be concluded that minimally invasive osteosynthesis with bridge plate can be considered a safe and effective option for the treatment of transverse fractures of the humeral shaft. Level of Evidence III, Therapeutic Study.2229498Angelini, A.J., Livani, B., Flierl, M.A., Morgan, S.J., Belangero, W.D., Less invasive percutaneous wave plating of simple femur shaft fractures. A prospective series (2010) Int Orthop., 41 (6), pp. 624-628Heitemeyer, U., Claes, L., Hierholzer, G., Körber, M., Significance of postoperativestability for bony reparation of comminuted fractures. An experimental study Arch Orthop Trauma Surg., 1990 (3), pp. 144-149Gerber, C., Mast, J.W., Ganz, R., Biological internal fixation of fractures (1990) Arch Orthop Trauma Surg., 109 (6), pp. 295-303Miclau, T., Martin, R.E., The evolution of modern plate osteosynthesis (1997) Injury., 28 (SUPPL. 1), pp. A3-6Farouk, O., Krettek, C., Miclau, T., Schandelmaier, P., Guy, P., Tscherne, H., Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver injection study (1997) Injury, 28 (SUPPL. 1), pp. A7-12Farouk, O., Krettek, C., Miclau, T., Schandelmaier, P., Guy, P., Tscherne, H., Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique? (1999) J Orthop Trauma., 13 (6), pp. 401-406Perren, S.M., Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology (2002) J Bone Joint Surg Br., 84 (8), pp. 1093-1110Livani, B., Belangero, W.D., Bridging plate osteosynthesis of humeral shaft fractures (2004) Injury., 35 (6), pp. 587-595Apivatthakakul, T., Arpornchayanon, O., Bavornratanavech, S., Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report (2005) Injury., 36 (4), pp. 530-538Apivatthakakul, T., Patiyasikan, S., Luevitoonvechkit, S., Danger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: a cadaveric study (2010) Injury., 41 (2), pp. 169-172Livani, B., Belangero, W.D., Castro de Medeiros, R., Fractures of the distal third of the humerus with palsy of the radial nerve: management usingn minimally- invasive percutaneous plate osteosynthesis (2006) J Bone Joint Surg Br., 88 (12), pp. 1625-1628Ziran, B.H., Belangero, W., Livani, B., Pesantez, R., Percutaneous plating of the humerus with locked plating: technique and case report (2007) J Trauma., 63 (1), pp. 205-210Schwarz, N., Windisch, M., Mayr, B., Minimally Invasive anterior plate osteosynthesis in humeral shaft fractures (2009) Eur J Trauma Emerg Surg., 35 (3), pp. 271-276Concha, J.M., Sandoval, A., Streubel, P.N., Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible? (2010) Int Orthop., 34 (8), pp. 1297-1305Hudak, P.L., Amadio, P.C., Bombardier, C., Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG) (1996) Am J Ind Med., 29 (6), pp. 602-608Thompson (1918) e Henry (1924 e 1966) - The humerus (2003) Surgical Exposures in Orthopaedics, pp. 67-103. , in: Hoppenfeld S., De Boer P., The anatomic Approach 3rd Ed;Charpter 2Livani, B., Belangero, W.D., Osteossíntese de fratura diafisária do úmero com placa em ponte: apresentação e descrição da técnica (2004) Acta Ortop Bras., 12 (2), pp. 113-117Gustilo, R.B., Anderson, J.T., Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses (1976) J Bone Joint Surg Am., 58 (4), pp. 453-458Gustilo, R.B., Mendoza, R.M., Williams, D.N., Problems in the management of type III (severe) open fractures: a new classification of type III open fractures (1984) J Trauma., 24 (8), pp. 742-746Benegas, E., Amódio, D.T., Correia, L.F.M., Malavolta, E.A., Ramadan, L.B., Ferreira Neto, A.A., Estudo comparativo prospectivo e randomizado entre o tratamento cirúrgico das fraturas diafisárias do úmero com placa em ponte e haste intra medular bloqueada (analise preliminar) (2007) Acta Ortop Bras., 15 (2), pp. 87-92Kobayashi, M., Watanabe, Y., Matsushita, T., Early full range of shoulder and elbow motion is possible after minimally invasive plate osteosynthesis for humeral shaft fractures (2010) J Orthop Trauma., 24 (4), pp. 212-216Hunsaker, F.G., Cioffi, D.A., Amadio, P.C., Wright, J.G., Caughlin, B., The American academy of orthopaedic surgeons outcomes instruments: normative values from the general population (2002) J Bone Joint Surg Am., 84 (2), pp. 208-21

    Impact of COVID-19 on the imaging diagnosis of cardiac disease in Europe

    No full text
    Objectives We aimed to explore the impact of the COVID-19 pandemic on cardiac diagnostic testing and practice and to assess its impact in different regions in Europe. Methods The online survey organised by the International Atomic Energy Agency Division of Human Health collected information on changes in cardiac imaging procedural volumes between March 2019 and March/April 2020. Data were collected from 909 centres in 108 countries. Results Centres in Northern and Southern Europe were more likely to cancel all outpatient activities compared with Western and Eastern Europe. There was a greater reduction in total procedure volumes in Europe compared with the rest of the world in March 2020 (45% vs 41%, p=0.003), with a more marked reduction in Southern Europe (58%), but by April 2020 this was similar in Europe and the rest of the world (69% vs 63%, p=0.261). Regional variations were apparent between imaging modalities, but the largest reductions were in Southern Europe for nearly all modalities. In March 2020, location in Southern Europe was the only independent predictor of the reduction in procedure volume. However, in April 2020, lower gross domestic product and higher COVID-19 deaths were the only independent predictors. Conclusion The first wave of the COVID-19 pandemic had a significant impact on care of patients with cardiac disease, with substantial regional variations in Europe. This has potential long-term implications for patients and plans are required to enable the diagnosis of non-COVID- 19 conditions during the ongoing pandemic.</p
    corecore