307 research outputs found

    ECG Round: A lady with dyspnoea for 2 days

    Get PDF
    published_or_final_versio

    Vibratory and perceptual measurement of resonant voice

    Get PDF
    Purpose: This study set out to investigate whether there existed a correlation between auditory-perceptual judgment of resonant voice and the physical vibration in the facial bone. The magnitude of bone vibration in the facial bone during different types of voice production (resonant vs nonresonant vs strained voices) was also investigated. Method: Thirty-six healthy normal subjects produced three types of phonations: resonant voice, habitual nonresonant voice, and strained voice. A piezoelectric accelerometer was used to measure the vibrations in the nasal bridge and the perilaryngeal area during the phonation. Seventy-two selected nasal sounds (/ma/) produced under the resonant voice condition by these speakers were rated by two experienced speech pathologists on the magnitude of auditory-perceptual resonance using an 11-point equal-appearing interval scale. The magnitude of bone vibration was also compared across the three voice types. Results: Significant moderate correlations were found between the physical bone vibration and the auditory-perceptual rating of resonant voice at the nasal bridge of the facial bone (0.6). Resonant voice, compared with the strained and nonresonant voice types, was also found to have a significant increase in the magnitude of facial bone vibration. Nasal stimuli, compared with nonnasal stimuli, facilitated greater bone vibration during resonant voice production. Conclusion: Piezoelectric accelerometer, as an objective quantitative tool, measures reliably the extent of bone vibration in resonant voice phonation. It is a useful tool for determining the bone vibration in relation to resonant voice. © 2012 The Voice Foundation.postprin

    International standards for fetal brain structures based on serial ultrasound measurements from the Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project.

    Get PDF
    OBJECTIVE: To create prescriptive growth standards for five fetal brain structures, measured by ultrasound, from healthy, well-nourished women, at low risk of impaired fetal growth and poor perinatal outcomes, taking part in the Fetal Growth Longitudinal Study (FGLS) of the INTERGROWTH-21st Project. METHODS: This was a complementary analysis of a large, population-based, multicentre, longitudinal study. We measured, in planes reconstructed from 3-dimensional (3D) ultrasound volumes of the fetal head at different time points in pregnancy, the size of the parieto-occipital fissure (POF), Sylvian fissure (SF), anterior horn of the lateral ventricle (AV), atrium of the posterior ventricle (PV) and cisterna magna (CM). The sample analysed was randomly selected from the overall FGLS population, ensuring an equal distribution amongst the eight diverse participating sites and of 3D ultrasound volumes across pregnancy (range: 15 - 36 weeks' gestation). Fractional polynomials were used to the construct standards. Growth and development of the infants were assessed at 1 and 2 years of age to confirm their adequacy for constructing international standards. RESULTS: From the entire FGLS cohort of 4321 women, 451 (10.4%) were randomly selected. After exclusions, 3D ultrasound volumes from 442 fetuses born without congenital malformations were used to create the charts. The fetal brain structures of interest were identified in 90% of cases. All structures showed increasing size with gestation and increasing variability for the POF, SF, PV and CM. The 3rd , 5th , 50th , 95th and 97th smoothed centile are presented. The 5th centile of POF and SF were 2.8 and 4.3 at 22 weeks and 4.2 and 9.4mm at 32 weeks respectively. The 95th centile of PV and CM were 8.5 and 7.4 at 22 weeks and 8.5 and 9.4mm at 32 weeks respectively. CONCLUSIONS: We have produced prescriptive size standards for fetal brain structures based on prospectively enrolled pregnancies at low risk of abnormal outcomes. We recommend these as international standards for the assessment of measurements obtained by ultrasound from fetal brain structures

    International standards for fetal growth based on serial ultrasound measurements: the Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project

    Get PDF
    Background: In 2006, WHO produced international growth standards for infants and children up to age 5 years on the basis of recommendations from a WHO expert committee. Using the same methods and conceptual approach, the Fetal Growth Longitudinal Study (FGLS), part of the INTERGROWTH-21st Project, aimed to develop international growth and size standards for fetuses. Methods: The multicentre, population-based FGLS assessed fetal growth in geographically defined urban populations in eight countries, in which most of the health and nutritional needs of mothers were met and adequate antenatal care was provided. We used ultrasound to take fetal anthropometric measurements prospectively from 14 weeks and 0 days of gestation until birth in a cohort of women with adequate health and nutritional status who were at low risk of intrauterine growth restriction. All women had a reliable estimate of gestational age confirmed by ultrasound measurement of fetal crown–rump length in the first trimester. The five primary ultrasound measures of fetal growth—head circumference, biparietal diameter, occipitofrontal diameter, abdominal circumference, and femur length—were obtained every 5 weeks (within 1 week either side) from 14 weeks to 42 weeks of gestation. The best fitting curves for the five measures were selected using second-degree fractional polynomials and further modelled in a multilevel framework to account for the longitudinal design of the study. Findings: We screened 13 108 women commencing antenatal care at less than 14 weeks and 0 days of gestation, of whom 4607 (35%) were eligible. 4321 (94%) eligible women had pregnancies without major complications and delivered live singletons without congenital malformations (the analysis population). We documented very low maternal and perinatal mortality and morbidity, confirming that the participants were at low risk of adverse outcomes. For each of the five fetal growth measures, the mean differences between the observed and smoothed centiles for the 3rd, 50th, and 97th centiles, respectively, were small: 2·25 mm (SD 3·0), 0·02 mm (3·0), and −2·69 mm (3·2) for head circumference; 0·83 mm (0·9), −0·05 mm (0·8), and −0·84 mm (1·0) for biparietal diameter; 0·63 mm (1·2), 0·04 mm (1·1), and −1·05 mm (1·3) for occipitofrontal diameter; 2·99 mm (3·1), 0·25 mm (3·2), and −4·22 mm (3·7) for abdominal circumference; and 0·62 mm (0·8), 0·03 mm (0·8), and −0·65 mm (0·8) for femur length. We calculated the 3rd, 5th 10th, 50th, 90th, 95th and 97th centile curves according to gestational age for these ultrasound measures, representing the international standards for fetal growth. Interpretation: We recommend these international fetal growth standards for the clinical interpretation of routinely taken ultrasound measurements and for comparisons across populations. Funding: Bill & Melinda Gates Foundation

    Postnatal growth standards for preterm infants: the Preterm Postnatal Follow-up Study of the INTERGROWTH-21(st) Project.

    Get PDF
    BACKGROUND: Charts of size at birth are used to assess the postnatal growth of preterm babies on the assumption that extrauterine growth should mimic that in the uterus. METHODS: The INTERGROWTH-21(st) Project assessed fetal, newborn, and postnatal growth in eight geographically defined populations, in which maternal health care and nutritional needs were met. From these populations, the Fetal Growth Longitudinal Study selected low-risk women starting antenatal care before 14 weeks' gestation and monitored fetal growth by ultrasonography. All preterm births from this cohort were eligible for the Preterm Postnatal Follow-up Study, which included standardised anthropometric measurements, feeding practices based on breastfeeding, and data on morbidity, treatments, and development. To construct the preterm postnatal growth standards, we selected all live singletons born between 26 and before 37 weeks' gestation without congenital malformations, fetal growth restriction, or severe postnatal morbidity. We did analyses with second-degree fractional polynomial regression models in a multilevel framework accounting for repeated measures. Fetal and neonatal data were pooled from study sites and stratified by postmenstrual age. For neonates, boys and girls were assessed separately. FINDINGS: From 4607 women enrolled in the study, there were 224 preterm singleton births, of which 201 (90%) were enrolled in the Preterm Postnatal Follow-up Study. Variance component analysis showed that only 0·2% and 4·0% of the total variability in postnatal length and head circumference, respectively, could be attributed to between-site differences, justifying pooling the data from all study sites. Preterm growth patterns differed from those for babies in the INTERGROWTH-21(st) Newborn Size Standards. They overlapped with the WHO Child Growth Standards for term babies by 64 weeks' postmenstrual age. INTERPRETATION: Our data have yielded standards for postnatal growth in preterm infants. These standards should be used for the assessment of preterm infants until 64 weeks' postmenstrual age, after which the WHO Child Growth Standards are appropriate. Size-at-birth charts should not be used to measure postnatal growth of preterm infants. FUNDING: Bill & Melinda Gates Foundation

    Ultrasound-based gestational-age estimation in late pregnancy.

    Get PDF
    OBJECTIVE: Accurate gestational-age (GA) estimation, preferably by ultrasound measurement of fetal crown-rump length before 14 weeks' gestation, is an important component of high-quality antenatal care. The objective of this study was to determine how GA can best be estimated by fetal ultrasound for women who present for the first time late in pregnancy with uncertain or unknown menstrual dates. METHODS: INTERGROWTH-21(st) was a large, prospective, multicenter, population-based project performed in eight geographically defined urban populations. One of its principal components, the Fetal Growth Longitudinal Study, aimed to develop international fetal growth standards. Each participant had their certain menstrual dates confirmed by first-trimester ultrasound examination. Fetal head circumference (HC), biparietal diameter (BPD), occipitofrontal diameter (OFD), abdominal circumference (AC) and femur length (FL) were measured every 5 weeks from 14 weeks' gestation until delivery. For each participant, a single, randomly selected ultrasound examination was used to explore all candidate biometric variables and permutations to build models to predict GA. Regression equations were ranked based upon minimization of the mean prediction error, goodness of fit and model complexity. An automated machine learning algorithm, the Genetic Algorithm, was adapted to evaluate > 64 000 potential polynomial equations as predictors. RESULTS: Of the 4607 eligible women, 4321 (94%) had a pregnancy without major complications and delivered a live singleton without congenital malformations. After other exclusions (missing measurements in GA window and outliers), the final sample comprised 4229 women. Two skeletal measures, HC and FL, produced the best GA prediction, given by the equation loge (GA) = 0.03243 × (loge (HC))(2) + 0.001644 × FL × loge (HC) + 3.813. When FL was not available, the best equation based on HC alone was loge (GA) = 0.05970 × (loge (HC))(2) + 0.000000006409 × (HC)(3) + 3.3258. The estimated uncertainty of GA prediction (half width 95% interval) was 6-7 days at 14 weeks' gestation, 12-14 days at 26 weeks' gestation and > 14 days in the third trimester. The addition of FL to the HC model led to improved prediction intervals compared with using HC alone, but no further improvement in prediction was afforded by adding AC, BPD or OFD. Equations that included other measurements (BPD, OFD and AC) did not perform better. CONCLUSIONS: Among women initiating antenatal care late in pregnancy, a single set of ultrasound measurements combining HC and FL in the second trimester can be used to estimate GA with reasonable accuracy. We recommend this tool for underserved populations but considerable efforts should be implemented to improve early initiation of antenatal care worldwide. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology

    Cardiovascular sequalae in uncomplicated COVID-19 survivors

    Get PDF
    BACKGROUND: A high proportion of COVID-19 patients were reported to have cardiac involvements. Data pertaining to cardiac sequalae is of urgent importance to define subsequent cardiac surveillance. METHODS: We performed a systematic cardiac screening for 97 consecutive COVID-19 survivors including electrocardiogram (ECG), echocardiography, serum troponin and NT-proBNP assay 1-4 weeks after hospital discharge. Treadmill exercise test and cardiac magnetic resonance imaging (CMR) were performed according to initial screening results. RESULTS: The mean age was 46.5 ± 18.6 years; 53.6% were men. All were classified with non-severe disease without overt cardiac manifestations and did not require intensive care. Median hospitalization stay was 17 days and median duration from discharge to screening was 11 days. Cardiac abnormalities were detected in 42.3% including sinus bradycardia (29.9%), newly detected T-wave abnormality (8.2%), elevated troponin level (6.2%), newly detected atrial fibrillation (1.0%), and newly detected left ventricular systolic dysfunction with elevated NT-proBNP level (1.0%). Significant sinus bradycardia with heart rate below 50 bpm was detected in 7.2% COVID-19 survivors, which appeared to be self-limiting and recovered over time. For COVID-19 survivors with persistent elevation of troponin level after discharge or newly detected T wave abnormality, echocardiography and CMR did not reveal any evidence of infarct, myocarditis, or left ventricular systolic dysfunction. CONCLUSION: Cardiac abnormality is common amongst COVID-survivors with mild disease, which is mostly self-limiting. Nonetheless, cardiac surveillance in form of ECG and/or serum biomarkers may be advisable to detect more severe cardiac involvement including atrial fibrillation and left ventricular dysfunction

    Control of Cyclin C Levels during Development of Dictyostelium

    Get PDF
    Background: Cdk8 and its partner cyclin C form part of the mediator complex which links the basal transcription machinery to regulatory proteins. The pair are required for correct regulation of a subset of genes and have been implicated in control of development in a number of organisms including the social amoeba Dictyostelium discoideum. When feeding, Dictyostelium amoebae are unicellular but upon starvation they aggregate to form a multicellular structure which develops into a fruiting body containing spores. Cells in which the gene encoding Cdk8 has been deleted fail to enter aggregates due to a failure of early gene expression.Principal Findings: We have monitored the expression levels of cyclin C protein during development and find levels decrease after the multicellular mound is formed. This decrease is triggered by extracellular cAMP that, in turn, is working in part through an increase in intracellular cAMP. The loss of cyclin C is coincident with a reduction in the association of Cdk8 with a high molecular weight complex in the nucleus. Overexpression of cyclin C and Cdk8 lead to an increased rate of early development, consistent with the levels being rate limiting.Conclusions: Overall these results show that both cyclin C and Cdk8 are regulated during development in response to extracellular signals and the levels of these proteins are important in controlling the timing of developmental processes. These findings have important implications for the role of these proteins in controlling development, suggesting that they are targets for developmental signals to regulate gene expression.</p
    • …
    corecore