10,790 research outputs found

    PANIC: the new panoramic NIR camera for Calar Alto

    Full text link
    PANIC is a wide-field NIR camera, which is currently under development for the Calar Alto observatory (CAHA) in Spain. It uses a mosaic of four Hawaii-2RG detectors and covers the spectral range from 0.8-2.5 micron(z to K-band). The field-of-view is 30x30 arcmin. This instrument can be used at the 2.2m telescope (0.45arcsec/pixel, 0.5x0.5 degree FOV) and at the 3.5m telescope (0.23arcsec/pixel, 0.25x0.25 degree FOV). The operating temperature is about 77K, achieved by liquid Nitrogen cooling. The cryogenic optics has three flat folding mirrors with diameters up to 282 mm and nine lenses with diameters between 130 mm and 255 mm. A compact filter unit can carry up to 19 filters distributed over four filter wheels. Narrow band (1%) filters can be used. The instrument has a diameter of 1.1 m and it is about 1 m long. The weight limit of 400 kg at the 2.2m telescope requires a light-weight cryostat design. The aluminium vacuum vessel and radiation shield have wall thicknesses of only 6 mm and 3 mm respectively.Comment: This paper has been presented in the SPIE of Astronomical Telescopes and Instrumentation 2008 in Marseille (France

    Microplate technique to determine hemolytic activity for routine typing of Listeria strains

    Get PDF
    Because the hemolysis produced by Listeria monocytogenes and Listeria seeligeri on blood agar is frequently difficult to interpret, we developed a microplate technique for the routine determination of hemolytic activity with erythrocyte suspensions. This microtechnique is a simple and reliable test for distinguishing clearly between hemolytic and nonhemolytic strains and could be used instead of the CAMP (Christie-Atkins-Munch-Petersen) test with Staphylococcus aureus in the routine typing of Listeria strains. Furthermore, our results suggest that the quantitation of the hemolytic activity of the Listeria strains, along with the D-xylose, L-rhamnose, and alpha-methyl-D-mannoside acidification tests, allows the differentiation of L. monocytogenes, L. seeligeri, and Listeria ivanovii. We also observed that the treatment of erythrocytes with crude exosubstances of rhodococcus equi, Pseudomonas fluorescens, Acinetobacter calcoaceticus, and S. aureus enhanced the hemolytic activity of all Listeria strains with this characteristic

    Muscle thickness and echogenicity measured by ultrasound could detect local sarcopenia and malnutrition in older patients hospitalized for hip fracture

    Get PDF
    Background: The aim of this work was to assess whether the muscle thickness and echogenicity were associated with dysphagia, malnutrition, sarcopenia, and functional capacity in acute hospital admission for a hip fracture. Methods: Observational study that assessed nutritional status by Global Leadership Initiative on Malnutrition, risk of dysphagia and sarcopenia by European Working Group on Sarcopenia in Older People and Barthel functional index. We measured muscle thickness and echogenicity of masseter, bicipital, and quadriceps rectus femoris (RF) and vastus intermedius (VI) by ultrasound. Results: One hundred and one patients were included in the study (29.7% sarcopenia and 43.8% malnutrition). Logistic regression models adjusted for age, sex, and body mass index showed an inverse association of the masseter thickness with both sarcopenia (OR: 0.56) and malnutrition (OR: 0.38) and quadriceps with sarcopenia (OR: 0.74). In addition, patients at high risk of dysphagia had lower masseter thickness (p: 0.0001) while patients able to self-feeding had thicker biceps (p: 0.002) and individuals with mobility on level surfaces higher thickness of biceps (p: 0.008) and quadriceps (p: 0.04). Conclusion: Thickness of the masseter was associated with risk of dysphagia, biceps with the ability to self-feed, and that of the quadriceps RF-VI with mobility

    The Air Microwave Yield (AMY) experiment - A laboratory measurement of the microwave emission from extensive air showers

    Full text link
    The AMY experiment aims to measure the microwave bremsstrahlung radiation (MBR) emitted by air-showers secondary electrons accelerating in collisions with neutral molecules of the atmosphere. The measurements are performed using a beam of 510 MeV electrons at the Beam Test Facility (BTF) of Frascati INFN National Laboratories. The goal of the AMY experiment is to measure in laboratory conditions the yield and the spectrum of the GHz emission in the frequency range between 1 and 20 GHz. The final purpose is to characterise the process to be used in a next generation detectors of ultra-high energy cosmic rays. A description of the experimental setup and the first results are presented.Comment: 3 pages -- EPS-HEP'13 European Physical Society Conference on High Energy Physics (July, 18-24, 2013) at Stockholm, Swede

    Percutaneous treatment with Mitraclip for functional mitral regurgitation: medium-term follow up according to left ventricular function

    Get PDF
    Background: Functional mitral regurgitation (FMR) is a bad prognosis condition despite optimal medical treatment. Nowadays there is an open debate about the surgical versus percutaneous treatment. The main objective of this study is to evaluate the mid-term follow up clinical outcomes of patients with FMR treated with MitraClip((R)) system, according to their left ventricular ejection fraction (LVEF). Methods: Data was obtained from two experienced centers in transcatheter mitral valve repair (TMVR). All consecutive cases of severe FMR undergoing TMVR in both centers with the same inclusion criteria were included prospectively in this study and followed-up. Periodical follow-ups with clinical and echocardiographic evaluation were scheduled from the baseline procedure, at 3 months and then yearly. Results: From October 2015 to October 2019, a total of 119 patients with FMR at 2 centers in Spain underwent TMVR with the MitraClip((R)) procedure and were included in this study. The mean age was 73.8+/-8.9 years old and 32 patients (26.9%) were female. A 39.5% of cases [47] had a LVEF 30% (group 2). There was a similar distribution in cardiovascular risk factors, age and other diseases. All MitraClip((R)) implantations were elective and procedural success was achieved in 110 patients (92.4%) with a similar distribution between the groups. There were no differences in procedural time and the number of implanted clips. The median follow-up was 22.6 months (IQR, 11.43-34.98 months). The primary combined endpoint occurred in the 41.6% of the global cohort, 57.5% in group 1 and 30.99% in group 2 (P=0.036). LVEF was associated to the main event in the multivariate analysis (HR 2.09, 95% CI: 1.12-3.89; P=0.02). Conclusions: The MitraClip edge-to-edge technique is a safe and effective procedure for the treatment of FMR. In this study, patients with LVEF >30% treated with Mitraclip presented better clinical cardiovascular outcomes than those with a LVEF </=30%. Regardless clinical outcomes, at the end of the follow-up, there was a sustained reduction in MR grades and an important improvement in NYHA functional class

    Ventricular arrhythmias in patients with functional mitral regurgitation and implantable cardiac devices: implications of mitral valve repair with Mitraclip

    Get PDF
    Background: Limited information has been reported regarding the impact of percutaneous mitral valve repair (PMVR) on ventricular arrhythmic (VA) burden. The aim of this study was to address the incidence of VA and appropriate antitachycardia implantable cardiac defibrillator (ICD) therapies before and after PMVR. Methods: We retrospectively analyzed all consecutive patients with heart failure with reduce left ventricular ejection fraction (LVEF), functional mitral regurgitation (FMR) grade 3+ or 4+ and an active ICD or cardiac resynchronizer who underwent PMVR in any of the eleven recruiting centers. Only patients with complete available device VA monitoring from one-year before to one year after PMVR were included. Baseline clinical and echocardiographic characteristics were collected before PMVR and at 12-months follow-up. Results: Ninety-three patients (68.2+/-10.9 years old, male 88.2%) were enrolled. PMVR was successfully performed in all patients and device success at discharge was 91.4%. At 12-month follow-up, we observed a significant reduction in mitral regurgitation severity, NT-proBNP and prevalence of severe pulmonary hypertension and severe kidney disease. Patients also referred a significant improvement in NYHA functional class and showed a non-significant trend to reserve left ventricular remodeling. After PMVR a significant decrease in the incidence of non-sustained ventricular tachycardia (VT) (5.0+/-17.8 vs. 2.7+/-13.5, P=0.002), sustained VT or ventricular fibrillation (0.9+/-2.5 vs. 0.5+/-2.9, P=0.012) and ICD antitachycardia therapies (2.5+/-12.0 vs. 0.9+/-5.0, P=0.033) were observed. Conclusions: PMVR was related to a reduction in arrhythmic burden and ICD therapies in our cohort
    • 

    corecore