584 research outputs found
Prediction of the haemodynamic response to tracheal intubation: comparison of laser-Doppler skin vasomotor reflex and pulse wave reflex
Background. The laser-Doppler skin vasomotor reflex (SVmR) caused by tetanic stimulation of the ulnar nerve may be a test that can predict the haemodynamic response to tracheal intubation. A decrease in pulse wave amplitude (pulse wave reflex, PWR) may be an alternative index of this response. We compared the abilities of PWR and SVmR to predict the haemodynamic response to tracheal intubation and studied how alfentanil, muscle relaxation, stimulation site and stimulation pattern affected the two reflexes. Methods. Anaesthesia was induced and maintained with 2% sevoflurane and 50% nitrous oxide in two groups of 10 ASA status I patients. Tetanic stimuli were applied to the flexor muscles of the forearm and the ulnar nerve before and after administration of vecuronium. The change in skin blood flow (laser-Doppler) and pulse wave amplitude (pulse oximetry) after a 5 and 10 s stimulation was measured on the opposite hand. If skin blood flow (laser-Doppler) decreased by more than 10%, a computer-controlled infusion of alfentanil was started and the target plasma concentration was increased in steps until this response was suppressed (<10%). The trachea was intubated and arterial pressure and heart rate responses were recorded. Plasma alfentanil concentration was measured. Results. When PWR and SVmR were suppressed, the haemodynamic response to tracheal intubation was reduced in 100 and 53% of patients respectively. PWR and SVmR responses decreased with increasing plasma alfentanil concentration. The SVmR response to muscle stimulation was reduced by muscle relaxants. The pulse wave response to both muscle and neural stimulation was reduced by relaxants. The responses to 5 and 10 s stimulations were similar. Conclusion. An absent SVmR does not predict a blunted arterial pressure or heart rate response to tracheal intubation. The PWR may be a better predicto
Impact of Prospective Screening for Multiple Endocrine Neoplasia Type 2
Prospective annual screening for hereditary medullary thyroid carcinoma (MTC) in the J-kindred, currently a 117-member family with multiple endocrine neoplasia type 2A, began in 1969. During the initial screening, 12 patients were found to have MTC. Subsequent screening has detected C-cell abnormalities (C-cell hyperplasia or microscopic MTC) in 22 of 23 addilional family members thyroidectomized for abnormal calcium- or pentagastrin-provocative calcitonin (CT) test results. Seven of the initial 12 patients thyroidectomized in 1970 to 1971 and 19 of 23 individuals thyroidectomized since 1971 remain disease-free by all criteria; three patients thyroidectomized since 1971 have had clearly abnormal serum CT measurements on one or more provocative tests. The significance of these abnormal test results is unclear because normal values were obtained when the samples were measured in another CT radioimmunoassay. Urine catecholamine abnormalities have been detected in 19 family members since 1969, resulting in ten bilateral and eight unilateral adrenalectomies. Four of the patients with initial unilateral adrenalectomy required reoperation for a pheochromocytoma in the contralateral gland nine to 13 years later. Hyperparathyroidism has not been observed in any of the family members with early C-cell disease. We conclude that prospective screening for hereditary MTC predicts histologic C-cell abnormalities in affected individuals, and follow-up of these patients provides support for the conclusion that early thyroidectomy is curative in most patients
Prediction of the haemodynamic response to tracheal intubation: comparison of laser-Doppler skin vasomotor reflex and pulse wave reflex
Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.
PURPOSE: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. METHODS: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. RESULTS: There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4-6.4, TC-STSF: mean = 3.2 years, 95% CI = 3-3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14-30) than TC-STSF (14 min, IQR: 8-25; p = 0.04). CONCLUSION: Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA
Recommended from our members
Direct Comparison of Adjacent Endocardial and Epicardial Electrograms: Implications for Substrate Mapping
Background: Analysis of unipolar voltage maps has been used to detect epicardial scar, but data to define optimal parameters to identify scar remote from the recording site is limited. This study compares the characteristics of electrograms at endocardial sites adjacent to abnormal epicardial sites. Methods and Results: Data obtained from endocardial and epicardial electroanatomical maps of 31 patients with scar‐related ventricular tachycardia were reviewed. Five hundred twenty‐three pairs of endo‐ and epicardial points were selected according to predefined criteria. The endocardial points adjacent to epicardial scar (bipolar voltage <1.5 mV) had smaller unipolar voltage than those distant from epicardial scar (P<0.001). In multivariable analysis, unipolar voltage was the only endocardial electrogram predictor of epicardial scar (P<0.001, OR 0.94, 95% CI 0.93 to 0.97). An endocardial unipolar amplitude <4.4 mV in the right ventricular (RV) (sensitivity 93%, specificity 76%) and <5.1 mV in the left ventricular (LV) (sensitivity 91%, specificity 75%) was the optimal cutoff predicting epicardial scar. Applying these thresholds to electroanatomical maps, revealed a good match between endocardial unipolar abnormality and epicardial scar for 67% of LV and 75% of RV maps, respectively, but notably poor matches occurred in 8 (29%) maps (7 with nonischemic cardiomyopathy). Site‐by‐site correlations were better for ischemic than nonischemic cardiomyopathy. Conclusions: This study supports the contention that unipolar electrograms are capable of indicating overlying epicardial scar during endocardial mapping, but illustrates limitations that appear to differ with nonischemic as compared to ischemic cardiomyopathy. The presence of epicardial arrhythmia substrate cannot be excluded by analysis of unipolar endocardial maps in some patients
High Pressure Insulator-Metal Transition in Molecular Fluid Oxygen
We report the first experimental evidence for a metallic phase in fluid
molecular oxygen. Our electrical conductivity measurements of fluid oxygen
under dynamic quasi-isentropic compression show that a non-metal/metal
transition occurs at 3.4 fold compression, 4500 K and 1.2 Mbar. We discuss the
main features of the electrical conductivity dependence on density and
temperature and give an interpretation of the nature of the electrical
transport mechanisms in fluid oxygen at these extreme conditions.Comment: RevTeX, 4 figure
High-Pressure Amorphous Nitrogen
The phase diagram and stability limits of diatomic solid nitrogen have been
explored in a wide pressure--temperature range by several optical spectroscopic
techniques. A newly characterized narrow-gap semiconducting phase has
been found to exist in a range of 80--270 GPa and 10--510 K. The vibrational
and optical properties of the phase produced under these conditions
indicate that it is largely amorphous and back transforms to a new molecular
phase. The band gap of the phase is found to decrease with pressure
indicating possible metallization by band overlap above 280 GPa.Comment: 5 pages, 4 figure
Prohormones in the early diagnosis of cardiac syncope
Background--The early detection of cardiac syncope is challenging. We aimed to evaluate the diagnostic value of 4 novel prohormones, quantifying different neurohumoral pathways, possibly involved in the pathophysiological features of cardiac syncope: midregional-pro-A-type natriuretic peptide (MRproANP), C-terminal proendothelin 1, copeptin, and midregionalproadrenomedullin. Methods and Results--We prospectively enrolled unselected patients presenting with syncope to the emergency department (ED) in a diagnostic multicenter study. ED probability of cardiac syncope was quantified by the treating ED physician using a visual analogue scale. Prohormones were measured in a blinded manner. Two independent cardiologists adjudicated the final diagnosis on the basis of all clinical information, including 1-year follow-up. Among 689 patients, cardiac syncope was the adjudicated final diagnosis in 125 (18%). Plasma concentrations of MRproANP, C-terminal proendothelin 1, copeptin, and midregional-proadrenomedullin were all significantly higher in patients with cardiac syncope compared with patients with other causes (P < 0.001). The diagnostic accuracies for cardiac syncope, as quantified by the area under the curve, were 0.80 (95% confidence interval [CI], 0.76-0.84), 0.69 (95% CI, 0.64-0.74), 0.58 (95% CI, 0.52-0.63), and 0.68 (95% CI, 0.63-0.73), respectively. In conjunction with the ED probability (0.86; 95% CI, 0.82-0.90), MRproANP, but not the other prohormone, improved the area under the curve to 0.90 (95% CI, 0.87-0.93), which was significantly higher than for the ED probability alone (P=0.003). An algorithm to rule out cardiac syncope combining an MRproANP level of < 77 pmol/L and an ED probability of < 20% had a sensitivity and a negative predictive value of 99%. Conclusions--The use of MRproANP significantly improves the early detection of cardiac syncope among unselected patients presenting to the ED with syncope
Consistent Anisotropic Repulsions for Simple Molecules
We extract atom-atom potentials from the effective spherical potentials that
suc cessfully model Hugoniot experiments on molecular fluids, e.g., and
. In the case of the resulting potentials compare very well with the
atom-atom potentials used in studies of solid-state propertie s, while for
they are considerably softer at short distances. Ground state (T=0K) and
room temperatu re calculations performed with the new potential resolve
the previous discrepancy between experimental and theoretical results.Comment: RevTeX, 5 figure
- …