1,727 research outputs found
AN INFORMATION SYSTEM DESIGN THEORY FOR AN RFID-BASED HEALTHCARE MANAGEMENT SYSTEM
This study is a design science research which describes the design of a radio frequency identification (RFID) based Healthcare Management System (RHMS) for the healthcare industry. In this study, a prototype RHMS has been designed and developed. The evaluations results validate the practical viability of the proposed architecture. We have described an Information System Design Theory for the RHMS which can form a basis for further research. We hope that the lessons learned from this study help support and further the efforts of academicians, researchers and practitioners in RFID based healthcare management system research
Automatic Management of Parallel and Distributed System Resources
Viewgraphs on automatic management of parallel and distributed system resources are presented. Topics covered include: parallel applications; intelligent management of multiprocessing systems; performance evaluation of parallel architecture; dynamic concurrent programs; compiler-directed system approach; lattice gaseous cellular automata; and sparse matrix Cholesky factorization
Continuous wave optical parametric oscillator for quartz-enhanced photoacoustic trace gas sensing
A continuous wave optical parametric oscillator, generating up to 300 mW idler output in the 3–4 μm wavelength region, and pumped by a fiber-amplified DBR diode laser is used for trace gas detection by means of quartz-enhanced photoacoustic spectroscopy (QEPAS). Mode-hop-free tuning of the OPO output over 5.2 cm-1 and continuous spectral coverage exceeding 16.5 cm-1 were achieved via electronic pump source tuning alone. Online monitoring of the idler wavelength, with feedback to the DBR diode laser, provided an automated closed-loop control allowing arbitrary idler wavelength selection within the pump tuning range and locking of the idler wavelength with a stability of 1.7×10-3 cm-1 over at least 30 min.\ud
\ud
Using this approach, we locked the idler wavelength at an ethane absorption peak and obtained QEPAS data to verify the linear response of the QEPAS signal at different ethane concentrations (100 ppbv-20 ppmv) and different power levels. The detection limit for ethane was determined to be 13 ppbv (20 s averaging), corresponding to a normalized noise equivalent absorption coefficient of 4.4×10-7 cm-1  W/Hz1/2
Non exponential relaxation in fully frustrated models
We study the dynamical properties of the fully frustrated Ising model. Due to
the absence of disorder the model, contrary to spin glass, does not exhibit any
Griffiths phase, which has been associated to non-exponential relaxation
dynamics. Nevertheless we find numerically that the model exhibits a stretched
exponential behavior below a temperature T_p corresponding to the percolation
transition of the Kasteleyn-Fortuin clusters. We have also found that the
critical behavior of this clusters for a fully frustrated q-state spin model at
the percolation threshold is strongly affected by frustration. In fact while in
absence of frustration the q=1 limit gives random percolation, in presence of
frustration the critical behavior is in the same universality class of the
ferromagnetic q=1/2-state Potts model.Comment: 7 pages, RevTeX, 11 figs, to appear on Physical Review
- …