443 research outputs found

    Effect of Calcium Source, Dietary Calcium Concentration, and Gestation Phase on Various Bone Characteristics in Gestating Gilts

    Get PDF
    Sixty gravid crossbred gilts were allotted to a 2 x 3 x 2 factorial arrangement of treatments: two Ca sources (sun-cured alfalfa meal and CaC03), three dietary concentrations of Ca (50, 75, and 100% of NRC requirements), and two phases of gestation (55 and 105 d). The objectives were to determine the effect of Ca source, dietary Ca concentration, and gestation phase on bone characteristics (bone breaking strength, bone ash percentage, bone density, and bone ash density in the rib, thoracic, and coccygeal bones), to correlate bone responses to determine relative bone activity, and to determine reliability of the coccygeal bones as indicators of Ca status in the body. At 55 d, rib strength and coccygeal ash content were lower (P \u3c .01) than at 105 d of gestation. A gestation phase x Ca concentration (P \u3c .05) interaction occurred. As Ca concentration increased, thoracic strength and rib ash responded quadratically during each gestation phase, for which at 55 d a minima and at 105 d a maxima was produced at 75% of NRC. A Ca source x Ca concentration ( P \u3c .05) interaction occurred. Gilts fed alfalfa had the lowest rib bone and ash density when fed 75% of NRC for Ca, whereas gilts fed CaC03 were highest at this level of Ca compared with the other concentrations. Generally, all bones were positively correlated with respect to their response to dietary Ca concentration. Few negative correlations were observed. At this level of physiological maturity, there was no effect of Ca source and little effect of gestation phase on the bone variables measured at the dietary Ca concentrations used in this experiment. The rib and thoracic bones seem to be the most responsive to dietary Ca concentration

    Search for a T-odd, P-even Triple Correlation in Neutron Decay

    Get PDF
    Background: Time-reversal-invariance violation, or equivalently CP violation, may explain the observed cosmological baryon asymmetry as well as signal physics beyond the Standard Model. In the decay of polarized neutrons, the triple correlation D\cdot(p_{e}\timesp_{\nu}) is a parity-even, time-reversal- odd observable that is uniquely sensitive to the relative phase of the axial-vector amplitude with respect to the vector amplitude. The triple correlation is also sensitive to possible contributions from scalar and tensor amplitudes. Final-state effects also contribute to D at the level of 1e-5 and can be calculated with a precision of 1% or better. Purpose: We have improved the sensitivity to T-odd, P-even interactions in nuclear beta decay. Methods: We measured proton-electron coincidences from decays of longitudinally polarized neutrons with a highly symmetric detector array designed to cancel the time-reversal-even, parity-odd Standard-Model contributions to polarized neutron decay. Over 300 million proton-electron coincidence events were used to extract D and study systematic effects in a blind analysis. Results: We find D = [-0.94\pm1.89(stat)\pm0.97(sys)]e-4. Conclusions: This is the most sensitive measurement of D in nuclear beta decay. Our result can be interpreted as a measurement of the phase of the ratio of the axial-vector and vector coupling constants (CA/CV= |{\lambda}|exp(i{\phi}_AV)) with {\phi}_AV = 180.012{\deg} \pm0.028{\deg} (68% confidence level) or to constrain time-reversal violating scalar and tensor interactions that arise in certain extensions to the Standard Model such as leptoquarks. This paper presents details of the experiment, analysis, and systematic- error corrections.Comment: 21 pages, 22 figure

    Studies of MCP-PMTs in the miniTimeCube neutrino detector

    Full text link
    This report highlights two different types of cross-talk in the photodetectors of the miniTimeCube neutrino experiment. The miniTimeCube detector has 24 8Ă—88 \times 8-anode Photonis MCP-PMTs Planacon XP85012, totalling 1536 individual pixels viewing the 2-liter cube of plastic scintillator

    Patient-reported outcome measures obtained via E-Health tools ease the assessment burden and encourage patient participation in cancer care (PaCC Study)

    Get PDF
    Patient-reported outcome measures obtained via E-Health tools ease the assessment burden and encourage patient participation in cancer care (PaCC Study) BACKGROUND: E-health based patient-reported outcome measures (PROMs) have the potential to automate early identification of both nutrition status and distress status in cancer patients while facilitating treatment and encouraging patient participation. This cross-sectional study assessed the acceptability, accuracy, and clinical utility of PROMs collected via E-Health tools among patients undergoing treatment for stomach, colorectal, and pancreatic tumors. RESULTS: Eight-nine percent mostly, or completely, agreed that PROMs via tablets should be integrated in routine clinical care. Men were significantly more likely to require help completing the questionnaires than women (inv.OR= 0.51, 95% CI=(0.27, 0.95), p = 0.035). The level of help needed increased by 3% with each 1-year increase in age (inv. OR=1.03, 95% CI=(1.01, 1.06), p = 0.013). On average, a patient tended to declare weight which was 0.84 kg inferior to their true weight (Bland and Altman 95 % CI=(-3.9, 5.6); SD: 2.41) and a height which was 0.95 cm superior to their true height (Bland and Altman 95 % CI=(-5, 3.1); SD 2.08). Patient-reported nutrition status was significantly associated with the professionally generated assessment (95% CI=(2.27, 4.15), p < 0.001). As nutrition status declined, the distress score increased (95%CI=(0.88, 1.68), p < 0.001). Of the patients, 48.8% who were both distressed and malnourished requested supportive care to address their problems. CONCLUSION: Patient-reported assessments utilizing E-health tools are an accurate and efficient method to encourage patient participation in cancer care while simultaneously ensuring that regular assessment of psycho-social and nutritional aspects of care are efficiently integrated in the daily clinical routine

    Precision Measurement of the Radiative B\Beta Decay of the Free Neutron

    Get PDF
    The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the β\beta decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335 ±\pm 0.00005 [stat] ±\pm 0.00015 [syst]. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14~keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582 ±\pm 0.00023 [stat] ±\pm 0.00062 [syst]. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies

    emiT: an apparatus to test time reversal invariance in polarized neutron decay

    Get PDF
    We describe an apparatus used to measure the triple-correlation term (\D \hat{\sigma}_n\cdot p_e\times p_\nu) in the beta-decay of polarized neutrons. The \D-coefficient is sensitive to possible violations of time reversal invariance. The detector has an octagonal symmetry that optimizes electron-proton coincidence rates and reduces systematic effects. A beam of longitudinally polarized cold neutrons passes through the detector chamber, where a small fraction beta-decay. The final-state protons are accelerated and focused onto arrays of cooled semiconductor diodes, while the coincident electrons are detected using panels of plastic scintillator. Details regarding the design and performance of the proton detectors, beta detectors and the electronics used in the data collection system are presented. The neutron beam characteristics, the spin-transport magnetic fields, and polarization measurements are also described.Comment: 15 pages, 13 figure

    Comments on Systematic Effects in the NIST Beam Neutron Lifetime Experiment

    Full text link
    We discuss issues raised by Serebrov, et al. in a recent paper regarding systematic effects in the beam neutron lifetime experiment performed at NIST. We show that these effects were considered in the original analyses and that our corrections and systematic uncertainties were appropriate. We point out some misconceptions and erroneous assumptions in the analysis of Serebrov, et al. None of the issues raised in Serebrov, et al lead us to alter the value of the neutron lifetime reported previously.Comment: arXiv admin note: substantial text overlap with arXiv:nucl-ex/0411041, arXiv:2004.0116

    New limit on time-reversal violation in beta decay

    Get PDF
    We report the results of an improved determination of the triple correlation DP . (p(e) x p(v)) that can be used to limit possible time-reversal invariance in the beta decay of polarized neutrons and constrain extensions to the standard model. Our result is D = [-0.96 +/- 1.89(stat) +/- 1.01(sys)] x 10(-4). The corresponding phase between g(A) and g(V) is phi(AV) = 180.013 degrees +/- 0.028 degrees (68% confidence level). This result represents the most sensitive measurement of D in nuclear beta decay
    • …
    corecore