97 research outputs found

    Evaluation of the prophylactic use of mitomycin-C to inhibit haze formation after photorefractive keratectomy in high myopia: a prospective clinical study

    Get PDF
    BACKGROUND: To study the effect of prophylactic application of mitomycin-C on haze formation in photorefractive keratectomy (PRK) for high myopia. METHODS: Fifty-four eyes of 28 myopic patients were enrolled in this prospective study. All eyes were operated by PRK followed by 0.02% mitomycin-C application for two minutes and washed with 20 ml normal saline afterwards. All eyes were examined thoroughly on the first 7 days and one month after surgery; 48 eyes (88.9%) at 3 and 6 months postoperatively. Hanna grading (in the scale of 0 to 4+) was used for assessment of corneal haze. RESULTS: The mean spherical equivalent refraction (SE) was -7.08 diopters (D) ± 1.11 (SD) preoperatively. Six months after surgery, 37 eyes (77.1%) achieved an uncorrected visual acuity (UCVA) of 20/20 or better, all eyes had a UCVA of 20/40 or better and 45 (93.7%) eyes had an SE within ± 1.00D. One month postoperatively, 2 eyes (3.7%) had grade 0.5+ of haze, while at 3 and 6 months after surgery no visited eye had haze at all. All eyes had a best corrected visual acuity (BCVA) of 20/40 or better and there were no lost lines in BCVA by 6 months after surgery. In spatial frequencies of 6 and 12 cycles per degree contrast sensitivity had decreased immediately after PRK and it had increased 1.5 lines by the 6(th )postoperative month compared to the preoperative data. CONCLUSIONS: The results show the efficacy of mitomycin-C in preventing corneal haze after treatment of high myopia with PRK. This method- PRK + mitomycin-C – can be considered an alternative treatment for myopic patients whose corneal thicknesses are inadequate for laser in situ keratomileusis (LASIK). However, the results should be confirmed in longer follow-ups

    Concept design of low frequency telescope for CMB B-mode polarization satellite LiteBIRD

    Get PDF
    LiteBIRD has been selected as JAXA’s strategic large mission in the 2020s, to observe the cosmic microwave background (CMB) B-mode polarization over the full sky at large angular scales. The challenges of LiteBIRD are the wide field-of-view (FoV) and broadband capabilities of millimeter-wave polarization measurements, which are derived from the system requirements. The possible paths of stray light increase with a wider FoV and the far sidelobe knowledge of -56 dB is a challenging optical requirement. A crossed-Dragone configuration was chosen for the low frequency telescope (LFT : 34–161 GHz), one of LiteBIRD’s onboard telescopes. It has a wide field-of-view (18° x 9°) with an aperture of 400 mm in diameter, corresponding to an angular resolution of about 30 arcminutes around 100 GHz. The focal ratio f/3.0 and the crossing angle of the optical axes of 90◦ are chosen after an extensive study of the stray light. The primary and secondary reflectors have rectangular shapes with serrations to reduce the diffraction pattern from the edges of the mirrors. The reflectors and structure are made of aluminum to proportionally contract from warm down to the operating temperature at 5 K. A 1/4 scaled model of the LFT has been developed to validate the wide field-of-view design and to demonstrate the reduced far sidelobes. A polarization modulation unit (PMU), realized with a half-wave plate (HWP) is placed in front of the aperture stop, the entrance pupil of this system. A large focal plane with approximately 1000 AlMn TES detectors and frequency multiplexing SQUID amplifiers is cooled to 100 mK. The lens and sinuous antennas have broadband capability. Performance specifications of the LFT and an outline of the proposed verification plan are presented

    LiteBIRD satellite: JAXA's new strategic L-class mission for all-sky surveys of cosmic microwave background polarization

    Get PDF
    LiteBIRD, the Lite (Light) satellite for the study of B-mode polarization and Inflation from cosmic background Radiation Detection, is a space mission for primordial cosmology and fundamental physics. JAXA selected LiteBIRD in May 2019 as a strategic large-class (L-class) mission, with its expected launch in the late 2020s using JAXA's H3 rocket. LiteBIRD plans to map the cosmic microwave background (CMB) polarization over the full sky with unprecedented precision. Its main scientific objective is to carry out a definitive search for the signal from cosmic inflation, either making a discovery or ruling out well-motivated inflationary models. The measurements of LiteBIRD will also provide us with an insight into the quantum nature of gravity and other new physics beyond the standard models of particle physics and cosmology. To this end, LiteBIRD will perform full-sky surveys for three years at the Sun-Earth Lagrangian point L2 for 15 frequency bands between 34 and 448 GHz with three telescopes, to achieve a total sensitivity of 2.16 μK-arcmin with a typical angular resolution of 0.5° at 100 GHz. We provide an overview of the LiteBIRD project, including scientific objectives, mission requirements, top-level system requirements, operation concept, and expected scientific outcomes

    Overview of the medium and high frequency telescopes of the LiteBIRD space mission

    Get PDF
    LiteBIRD is a JAXA-led Strategic Large-Class mission designed to search for the existence of the primordial gravitational waves produced during the inflationary phase of the Universe, through the measurements of their imprint onto the polarization of the cosmic microwave background (CMB). These measurements, requiring unprecedented sensitivity, will be performed over the full sky, at large angular scales, and over 15 frequency bands from 34 GHz to 448 GHz. The LiteBIRD instruments consist of three telescopes, namely the Low-, Medium-and High-Frequency Telescope (respectively LFT, MFT and HFT). We present in this paper an overview of the design of the Medium-Frequency Telescope (89{224 GHz) and the High-Frequency Telescope (166{448 GHz), the so-called MHFT, under European responsibility, which are two cryogenic refractive telescopes cooled down to 5 K. They include a continuous rotating half-wave plate as the first optical element, two high-density polyethylene (HDPE) lenses and more than three thousand transition-edge sensor (TES) detectors cooled to 100 mK. We provide an overview of the concept design and the remaining specific challenges that we have to face in order to achieve the scientific goals of LiteBIRD

    Influence of co-payment levels on patient and surgeon acceptance of advanced technology intraocular lenses.

    No full text
    PURPOSE: To investigate patients' willingness to pay for advanced technology intraocular lenses and surgeons' willingness to recommend them. METHODS: In this study, 370 cataract surgeons and 700 patients undergoing cataract surgery from seven countries underwent online interviews in which they were shown unbranded profiles of three advanced technology intraocular lenses (ie, biconvex toric aspheric optic, symmetric biconvex diffractive optic, and biconvex diffractive aspheric toric) and asked to indicate their willingness to accept (for patients) or suggest (for surgeons) each lens. Acceptance was assessed assuming there was either no co-payment or co-payments of €500 to €1,500 +15%. RESULTS: All three lenses were widely accepted by patients, with 68% to 99% indicating acceptance when there was no co-payment. In contrast, surgeons' willingness to suggest them was markedly lower (20% to 43%). Both patients' acceptance of the lenses and surgeons' willingness to suggest them decreased with increasing co-payment levels to 19% to 74% (patients) and 5% to 31% (surgeons) at the highest co-payment levels. CONCLUSIONS: There is a marked discrepancy between patients' acceptance of the three lenses and surgeons' willingness to suggest them. Although patients' acceptance is high, it decreases with increasing out-of-pocket expenditure. Manufacturers should communicate the relative benefits and costs of their lenses to both surgeons and patients

    Influence of co-payment levels on patient and surgeon acceptance of advanced technology intraocular lenses.

    No full text
    PURPOSE: To investigate patients' willingness to pay for advanced technology intraocular lenses and surgeons' willingness to recommend them. METHODS: In this study, 370 cataract surgeons and 700 patients undergoing cataract surgery from seven countries underwent online interviews in which they were shown unbranded profiles of three advanced technology intraocular lenses (ie, biconvex toric aspheric optic, symmetric biconvex diffractive optic, and biconvex diffractive aspheric toric) and asked to indicate their willingness to accept (for patients) or suggest (for surgeons) each lens. Acceptance was assessed assuming there was either no co-payment or co-payments of €500 to €1,500 +15%. RESULTS: All three lenses were widely accepted by patients, with 68% to 99% indicating acceptance when there was no co-payment. In contrast, surgeons' willingness to suggest them was markedly lower (20% to 43%). Both patients' acceptance of the lenses and surgeons' willingness to suggest them decreased with increasing co-payment levels to 19% to 74% (patients) and 5% to 31% (surgeons) at the highest co-payment levels. CONCLUSIONS: There is a marked discrepancy between patients' acceptance of the three lenses and surgeons' willingness to suggest them. Although patients' acceptance is high, it decreases with increasing out-of-pocket expenditure. Manufacturers should communicate the relative benefits and costs of their lenses to both surgeons and patients

    Intense Pulsed Light for the Treatment of Dry Eye Owing to Meibomian Gland Dysfunction

    No full text
    Dry eye disease (DED) is an increasingly common condition and one of the most common complaints of patients. The vast majority of DED is caused by the so-called "evaporative" subtype, that is mainly caused by meibomian gland dysfunction (MGD). Intense pulsed light (IPL) devices employ high intensity pulses of polychromatic lights with a broad range of wavelength (515-1200 nm). IPL treatment has been utilized for years in the field of dermatology, and then its use was applied to ophthalmology for the treatment of MGD. Recently, a new device employing IPL was specifically designed for the periocular application. This procedure determines the thermal selective coagulation and ablation of superficial blood vessels and telangiectasias of the eyelids skin, reducing the release of inflammatory mediators and tear cytokines levels, and improving meibomian glands outflow. IPL treatment is noninvasive and easy to perform, lasts for only a few minutes and can be conducted in an office setting. In the present study, 19 patients underwent 3 sessions of IPL treatment. After treatment, both mean noninvasive break-up time and lipid layer thickness grade significantly increased, as a result of an improvement of tear film stability and quality, respectively. Conversely, no statistically significant changes were found for meibomian gland loss and tear osmolarity. Furthermore, the vast majority of the treated patients (17/19; 89.5% of the total) perceived an improvement of their ocular discomfort symptoms after IPL treatment. Although IPL treatment provides an improvement of both ocular surface parameters and ocular discomfort symptoms after one cycle of three sessions, regular repeated treatments are usually required to maintain the persistence over the time of its beneficial effects

    The effect of different optical zone diameters on the results of high-order aberrations in femto-laser-assisted in situ keratomileusis

    No full text
    Purpose: To evaluate the postoperative high-order aberration differences of femto-LASIK surgery in 6.5 and 7?mm optic zones. Patients and Methods: We retrospectively reviewed 80 eyes of 40 patients with myopia or myopia with astigmatism who underwent femtosecond LASIK surgery. Q values, z3, 3 (h. trefoil), z3, –3 (v. trefoil), z3, 1 (h. coma), z3, –1 (vertical coma), z4, 0 (spherical aberration), z5, –1 (second other v. coma), aberration coefficients were evaluated 3?months after surgery. Central corneal thicknesses, intraocular pressures, patient ages and genders, optical zone diameters and ablation depths are collected from patients’ medical records. Results: The mean age was 28.4?±?0.69?years (range, 20–47?years). Lower z4, 0 spherical aberrations and aberration coefficient values were associated with larger optical zones (7?mm) (z4, 0 spherical aberrations?=?1.25, p?=?0.01; coefficient value?=?–1.21, p?<?0.01). Although a smaller optical zone (6.5?mm) was associated with an increase in most of the wave-front aberration variables, measurements were not statistically different between the two groups other than z4, 0 spherical aberrations and aberration coefficients. Discussion: LASIK treatment with 6.5 and 7?mm optical zones is safe and effective for correcting myopia and myopic astigmatism and has statistically similar visual outcomes. Moreover, larger optical zone (7?mm) was found to be associated with lower spherical aberration induction and smaller aberration coefficient values compared to 6.5?mm optical zone. This can be important for decision-making in femto-LASIK surgery for better postoperative results
    • …
    corecore