4,016 research outputs found
The art and science of predicting postrevascularization improvement in left ventricular (LV) function in patients with severely depressed LV function**Editorials published in the Journal of the American College of Cardiologyreflect the views of the authors and do not necessarily represent the views of JACCor the American College of Cardiology.
Myocardial Perfusion Imaging and Multidetector Computed Tomographic Coronary Angiography Appropriate for All Patients With Suspected Coronary Artery Disease?⁎⁎Editorials published in the Journal of the American College of Cardiologyreflect the views of the authors and do not necessarily represent the views of JACCor the American College of Cardiology.
Cardiopulmonary-bypass induces hyperglycemia only in preoperative insulin resistant patients
n/
Recommended from our members
Feasibility study of electrocardiographic and respiratory gated, gadolinium enhanced magnetic resonance angiography of pulmonary veins and the impact of heart rate and rhythm on study quality
Background: We aimed to assess the feasibility of 3 dimensional (3D) respiratory and ECG gated, gadolinium enhanced magnetic resonance angiography (MRA) on a 3 Tesla (3 T) scanner for imaging pulmonary veins (PV) and left atrium (LA). The impact of heart rate (HR) and rhythm irregularity associated with atrial fibrillation (AF) on image and segmentation qualities were also assessed. Methods: 101 consecutive patients underwent respiratory and ECG gated (ventricular end systolic window) MRA for pre AF ablation imaging. Image quality (assessed by PV delineation) was scored as 1 = not visualized, 2 = poor, 3 = good and 4 = excellent. Segmentation quality was scored on a similar 4 point scale. Signal to noise ratios (SNRs) were calculated for the LA, LA appendage (LAA), and PV. Contrast to noise ratios (CNRs) were calculated between myocardium and LA, LAA and PV, respectively. Associations between HR/rhythm and quality metrics were assessed. Results: 35 of 101 (34.7%) patients were in AF at time of MRA. 100 (99%) patients had diagnostic studies, and 91 (90.1%) were of good or excellent quality. Overall, mean ± standard deviation (SD) image quality score was 3.40 ± 0.69. Inter observer agreement for image quality scores was substantial, (kappa = 0.68; 95% confidence interval (CI): 0.46, 0.90). Neither HR adjusting for rhythm [odds ratio (OR) = 1.03, 95% CI = 0.98,1.09; p = 0.22] nor rhythm adjusting for HR [OR = 1.25, 95% CI = 0.20, 7.69; p = 0.81] demonstrated association with image quality. Similarly, SNRs and CNRs were largely independent of HR after adjusting for rhythm. Segmentation quality scores were good or excellent for 77.3% of patients: mean ± SD score = 2.91 ± 0.63, and scores did not significantly differ by baseline rhythm (p = 0.78). Conclusions: 3D respiratory and ECG gated, gadolinium enhanced MRA of the PVs and LA on a 3 T system is feasible during ventricular end systole, achieving high image quality and high quality image segmentation when imported into electroanatomic mapping systems. Quality is independent of HR and heart rhythm for this free breathing, radiation free, alternative strategy to current MRA or CT based approaches, for pre AF ablation imaging of PVs and LA
Tunable Short-Term Plasticity Response in Three-Terminal Organic Neuromorphic Devices
Reversibly tunable short-term plasticity (STP) of the channel current in organic neuromorphic devices is demonstrated with a three-terminal architecture. Electrolyte-gated organic transistors - EGOTs - are driven with square voltage pulses at the drain electrodes, while the gate bias enables the modulation of the amplitude and characteristic time scale of the depressive STP spiking response up to 1 order of magnitude. The gate potential sets the baseline and the steady-state current, preluding multilevel memory writing. The fine-tuning of the STP response, which is not possible with two-electrode organic neuromorphic devices, is reversible and does not imply chemical modifications of the active layer
Retrieval of foreign-broadened water vapor continuum coefficients from emitted spectral radiance in the H2O rotational band from 240 to 590 cm −1
The paper presents a novel methodology to retrieve the foreign-broadened water vapor continuum absorption coefficients in the
spectral range 240 to 590 cm−1 and is the first estimation of the continuum coefficient at wave numbers smaller than 400 cm−1 under atmospheric conditions. The derivation has been accomplished by processing a suitable
set of atmospheric emitted spectral radiance observations obtained during the March 2007 Alps campaign of the ECOWAR project (Earth COoling by WAter vapor Radiation). It is shown that, in the range 450 to 600 cm−1, our findings are in good agreement with the widely used Mlawer, Tobin-Clough, Kneizys-Davies (MT_CKD) continuum. Below 450 cm−1 however the MT_CKD model overestimates the magnitude of the continuum coefficient.Published15816-158331.8. Osservazioni di geofisica ambientaleJCR Journalreserve
Floristic and coenological data from the travertine substrates of the SAC “Travertini Acque Albule (Bagni di Tivoli)” (Lazio Region – Central Italy)
During a phytosociological field-work campaign on the vegetation of the travertine outcrops, included in the Special Area of Conservation (SAC) “Travertini Acque Albule (Bagni di Tivoli)” (Central Italy), several taxa of particular interest were identified. Carex vulpina, Lolium apenninum, Onosma echioides subsp. angustifolia, Typha domingensis, T. laxmannii and Vicia pannonica subsp. pannonica are new for the Lazio administrative Region, while Ophrys illyrica and Zannichellia peltata are confirmed for the flora of this Region. For each of these taxa phytosociological samples describing the plant communities in which they were found are provided. New records for rare species were also reported for cryptogams such as Algae, Lichens and Mosses
Multifunctionally-doped PEDOT for organic electrochemical transistors
Organic Electrochemical Transistors (OECTs) are suitable for developing ultra-sensitive bioelectronic sensors. In the organic electrochemical transistors architecture, the source-drain channel is made of a conductive polymer film either cast from a formulated dispersion or electrodeposited from a monomer solution. The commercial poly(3,4-ethylenedioxidethiophene)/poly(styrene sulfonate) (PEDOT:PSS) water dispersion is the workhorse of organic bioelectronics for its high conductance, low impact and ease of processability. In this study, a hybrid organic electrochemical transistors channel fabrication strategy is presented, where electrochemical deposition of a PEDOT/X (with X indicating the counterion) is performed on a dispersion-cast PEDOT:PSS film. Six different counterions where used: X = PSS, Nafion, Hyaluronate, Dextran sulfate, Dexamethasone phosphate and tauroursodeoxycholic acid, each potentially endowing organic electrochemical transistors with additional functions such as ion exchange and pharmacological activity upon release of X. The PEDOT/X-PEDOT:PSS bilayers were characterized by means of electrochemical impedance spectroscopy (EIS), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and focused ion beam tomography combined with scanning electron microscopy (FIB-SEM). In addition, their respective organic electrochemical transistorss were characterized and compared to PEDOT:PSS organic electrochemical transistors. Our results show that the hybrid bilayer strategy is viable to fabricate multifunctional organic electrochemical transistorss with biologically-relevant function, thereby retaining the outstanding figures of merit of commercial PEDOT:PSS
Recommended from our members
Identification of coronary heart disease in asymptomatic individuals with diabetes mellitus: to screen or not to screen
Coronary heart disease (CHD) is highly prevalent in patients with diabetes mellitus (DM), and remains the single most common cause of death among this population. Regrettably, a significant percentage of diabetics fail to perceive the classic symptoms associated with myocardial ischemia. Among asymptomatic diabetics, the prevalence of abnormal cardiac testing appears to be high, ranging between 10% and 62%, and mortality is significantly higher in those with abnormal scans. Hence, the potential use of screening for CHD detection among asymptomatic DM individuals is appealing and has been recommended in certain circumstances. However, it was not until recently, that this question was addressed in clinical trials. Two studies randomized a total of 2,023 asymptomatic diabetics to screening or not using cardiac imaging with a mean follow up of 4.4 ± 1.4 years. In combination, both trials showed lower than expected annual event rates, and failed to reduce major cardiovascular events in the screened group compared to the standard of care alone. The results of these trials do not currently support the use of screening tools for CHD detection in asymptomatic DM individuals. However, these studies have important limitations, and potential explanations for their negative results that are discussed in this manuscript
Amending entanglement-breaking channels via intermediate unitary operations
We report a bulk optics experiment demonstrating the possibility of restoring the entanglement distribution through noisy quantum channels by inserting a suitable unitary operation (filter) in the middle of the transmission process. We focus on two relevant classes of single-qubit channels consisting in repeated applications of rotated phase-damping or rotated amplitude-damping maps, both modeling the combined Hamiltonian and dissipative dynamics of the polarization state of single photons. Our results show that interposing a unitary filter between two noisy channels can significantly improve entanglement transmission. This proof-of-principle demonstration could be generalized to many other physical scenarios where entanglement-breaking communication lines may be amended by unitary filters
- …