134 research outputs found

    ANALISA KUALITAS AIR DI PANTAI KUALA TANJUNG, DESA KUALA INDAH KABUPATEN BATU BARA TAHUN 2021 (STUDI KASUS KEMATIAN MASSAL IKAN)

    Get PDF
    Thousands of fish were seen suddenly dying in the waters of Kuala Indah, Sei Suka District, Batubara Regency. Based on information from the community, the alleged cause of the mass death of fish that occurred on April 24, 2021 was caused by the input of domestic and industrial waste and the explosion of the plankton population. The purpose of this study was to determine the factors causing mass death of fish through analysis of water quality parameters with physical, chemical and microbiological tests of river, estuary and sea water. The method used to analyze river, estuary and sea water samples is using standard methodstesting, 23rd edition 2017, APHA-AWWA-WEF. Parameter testing includes three physical parameters, the 17 chemical parameters and two biological parameters analyzed were then compared with quality standards according to Government Regulation number 22 of 2021 concerning the Implementation of Environmental Protection and Management. Based on the research results, the range of index values of water quality ​​obtained is 75-80 and is included in good criteria, so it can be concluded that anthropogenic activities in river, estuary and sea waters are not the cause of mass fish death.   ABSTRAK Ribuan ekor ikan terlihat mendadak mati di perairan Kuala Indah Kecamatan Sei Suka Kabupaten Batubara. Berdasarkan informasi dari masyarakat, dugaan penyebab terjadinya kematian massal ikan yang terjadi pada 24 April 2021 disebabkan oleh masukan limbah domestik dan industri serta ledakan populasi plankton. Tujuan penelitian ini adalah untuk mengetahui faktor penyebab kematian massal ikan melalui analisis parameter kualitas air dengan uji fisika, kimia dan mikrobiologi air sungai, muara dan laut. Metode yang digunakan untuk analisa sampel air sungai, muara dan laut yaitu menggunakan pengujian standard methods, 23rd edition 2017, APHA-AWWA-WEF. Pengujian parameter meliputi tiga parameter fisika, 17 parameter kimia dan dua parameter biologi yang dianalisi kemudian dibandingkan dengan baku mutu sesuai Peraturan Pemerintah nomor 22 tahun 2021 tentang  Penyelenggaraan Perlindungan dan Pengelolaan Lingkungan Hidup. Berdasarkan hasil penelitian kisaran nilai indeks kualitas air yang diperoleh adalah 75-80 dan termasuk dalam kriteria baik, sehingga dapat disimpulkan bahwa kegiatan antropogenik di perairan sungai, muara dan laut bukan merupakan penyebab terjadinya kematian massal ikan.   Kata kunci : Kematian ikan, kualitas air, antropogenik, Kuala Indah, Kabupaten Batu Bar

    A Novel, Orally Delivered Antibody Therapy and Its Potential to Prevent Clostridioides difficile Infection in Pre-clinical Models

    Get PDF
    Clostridioides difficile infection (CDI) is a toxin-mediated infection in the gut and a major burden on healthcare facilities worldwide. We rationalized that it would be beneficial to design an antibody therapy that is delivered to, and is active at the site of toxin production, rather than neutralizing the circulating and luminal toxins after significant damage of the layers of the intestines has occurred. Here we describe a highly potent therapeutic, OraCAb, with high antibody titers and a formulation that protects the antibodies from digestion/inactivation in the gastrointestinal tract. The potential of OraCAb to prevent CDI in an in vivo hamster model and an in vitro human colon model was assessed. In the hamster model we optimized the ratio of the antibodies against each of the toxins produced by C. difficile (Toxins A and B). The concentration of immunoglobulins that is effective in a hamster model of CDI was determined. A highly significant difference in animal survival for those given an optimized OraCAb formulation versus an untreated control group was observed. This is the first study testing the effect of oral antibodies for treatment of CDI in an in vitro gut model seeded with a human fecal inoculum. Treatment with OraCAb successfully neutralized toxin production and did not interfere with the colonic microbiota in this model. Also, treatment with a combination of vancomycin and OraCAb prevented simulated CDI recurrence, unlike vancomycin therapy alone. These data demonstrate the efficacy of OraCAb formulation for the treatment of CDI in pre-clinical models

    Development of a 2K x 2K GaAs QWIP Focal Plane Array

    Get PDF
    We are developing the next generation of GaAs Quantum Well Infrared Photodetector (QWIP) focal plane arrays (FPAs) in preparation for future NASA space-borne Earth observing missions. It is anticipated that these missions will require both wider ground spatial coverage as well as higher ground imaging resolution. In order to demonstrate our capability in meeting these future goals we have taken a two-tiered approach in the next stage of advanced QWIP focal plane array development. We will describe our progress in the development of a 512 x 3,200 (512 x 3K) array format for this next generation thermal imaging array for the NASA Landsat project. However, there currently is no existing readout integrated circuit (ROIC) for this format array.so to demonstrate the ability to scale-up an existing ROIC we developed a 1,920 x 2,048 (2K x 2K) array and it hybridized to a Raytheon SB419 CTIA readout integrated circuit that was scaled up from their existing 512 x 640 SB339 ROIC. Two versions of the 512 x 3K QWIP array were fabricated to accommodate a future design scale-up of both the Indigo 9803 ROIC based on a 25 micron pixel dimension and a scale up of the Indigo 9705 ROIC based on a 30 micron pixel dimension. Neither readout for the 512 x 3K has yet to be developed but we have fabricated both versions of the array. We describe the design, development and test results of this effort as well as the specific applications these FPAs are intended to address

    Omadacycline gut microbiome exposure does not induce Clostridium difficile proliferation or toxin production in a model that simulates the proximal, medial and distal human colon

    Get PDF
    A clinically reflective model of the human colon was used to investigate the effects of the broad-spectrum antibiotic omadacycline on the gut microbiome, and subsequent potential to induce simulated Clostridium difficile infection (CDI). Triple stage chemostat gut models were inoculated with pooled human faecal slurry from healthy volunteers (age ≥60 years). Models were challenged twice with 107 cfu C. difficile spores (PCR ribotype 027). Omadacycline effects were assessed in a single gut model. Observations were confirmed in a parallel study with omadacycline and moxifloxacin. Antibiotic instillation was performed once daily for 7 days. The models were observed for 3 weeks post-antibiotic challenge. Gut microbiota populations and C. difficile total viable and spore counts were enumerated daily by culture. Cytotoxin titres and antibiotic concentrations were also measured. Gut microbiota populations were stable before antibiotic challenge. Moxifloxacin instillation caused a ∼4 log10 cfu/mL decline in enterococci and Bacteroides fragilis group populations, and a ∼3 log10 cfu/mL decline in bifidobacteria and lactobacilli, followed by simulated CDI (vegetative cell proliferation and detectable toxin). In both models, omadacycline instillation decreased populations of bifidobacteria (∼8 log10 cfu/mL), B. fragilis group populations (7-8 log10 cfu/mL), lactobacilli (2-6 log10 cfu/mL), and enterococci (4-6 log10 cfu/mL). Despite these microbial shifts, there was no evidence of C. difficile germination or toxin production. In contrast to moxifloxacin, omadacycline exposure did not facilitate simulated CDI, suggesting this antibiotic may have a low propensity to induce CDI in the clinical setting

    Profiling the Effects of Systemic Antibiotics for Acne, Including the Narrow-Spectrum Antibiotic Sarecycline, on the Human Gut Microbiota

    Get PDF
    Treatment for moderate-to-severe acne vulgaris relies on prolonged use of oral tetracycline-class antibiotics; however, these broad-spectrum antibiotics are often associated with off-target effects and negative gastrointestinal sequelae. Sarecycline is a narrow-spectrum antibiotic treatment option. Here, we investigated the effect of prolonged sarecycline exposure, compared with broad-spectrum tetracyclines (doxycycline and minocycline) upon the colonic microbiota. Three in vitro models of the human colon were instilled with either minocycline, doxycycline or sarecycline, and we measured microbiota abundance and diversity changes during and after antibiotic exposure. Significant reductions in microbial diversity were observed following minocycline and doxycycline exposure, which failed to recover post antibiotic withdrawal. Specifically, minocycline caused a ~10% decline in Lactobacillaceae and Bifidobacteriaceae abundances, while doxycycline caused a ~7% decline in Lactobacillaceae and Bacteroidaceae abundances. Both minocycline and doxycycline were associated with a large expansion (>10%) of Enterobacteriaceae. Sarecycline caused a slight decline in bacterial diversity at the start of treatment, but abundances of most families remained stable during treatment. Ruminococcaceae and Desulfovibrionaceae decreased 9% and 4%, respectively, and a transient increased in Enterobacteriaceae abundance was observed during sarecycline administration. All populations recovered to pre-antibiotic levels after sarecycline exposure. Overall, sarecycline had minimal and transient impact on the gut microbiota composition and diversity, when compared to minocycline and doxycycline

    Development of Kilo-Pixel Arrays of Transition-Edge Sensors for X-Ray Spectroscopy

    Get PDF
    We are developing kilo-pixel arrays of transition-edge sensor (TES) microcalorimeters for future X-ray astronomy observatories or for use in laboratory astrophysics applications. For example, Athena/XMS (currently under study by the european space agency) would require a close-packed 32x32 pixel array on a 250-micron pitch with < 3.0 eV full-width-half-maximum energy resolution at 6 keV and at count-rates of up to 50 counts/pixel/second. We present characterization of 32x32 arrays. These detectors will be readout using state of the art SQUID based time-domain multiplexing (TDM). We will also present the latest results in integrating these detectors and the TDM readout technology into a 16 row x N column field-able instrument

    Multi-Absorber Transition-Edge Sensors for X-Ray Astronomy Applications

    Get PDF
    We are developing multi-absorber Transition-Edge Sensors (TESs) for applications in x-ray astronomy. These position-sensitive devices consist of multiple x-ray absorbers each with a different thermal coupling to a single readout TES. Heat diffusion between the absorbers and the TES gives rise to a characteristic pulse shape corresponding to each absorber element and enables position discrimination. The development of these detectors is motivated by a desire to maximize focal plane arrays with the fewest number of readout channels. In this contribution we report on the first results from devices consisting of nine) 65 X 65 sq. microns Au x-ray absorbers) 5 microns thick. These are coupled to a single 35 X 35 sq. microns Mo/Au bilayer TES. These devices have demonstrated full-width-half-maximum (FWHM) energy resolution of 2.1 eV at 1.5 keV) 2.5 eV at 5.9 keV and 3.3 eV at 8 keV. This is coupled with position discrimination from pulse shape over the same energy range. We use a finite-element model to reproduce the measured pulse shapes and investigate the detector non-linearity with energy) which impacts on the devices position sensitivity and energy resolution

    Advances in Small Pixel TES-Based X-Ray Microcalorimeter Arrays for Solar Physics and Astrophysics

    Get PDF
    We are developing small-pixel transition-edge-sensor (TES) for solar physics and astrophysics applications. These large format close-packed arrays are fabricated on solid silicon substrates and are designed to accommodate count-rates of up to a few hundred counts/pixel/second at a FWHM energy resolution approximately 2 eV at 6 keV. We have fabricated versions that utilize narrow-line planar and stripline wiring. We present measurements of the performance and uniformity of kilo-pixel arrays, incorporating TESs with single 65-micron absorbers on a 7s-micron pitch, as well as versions with more than one absorber attached to the TES, 4-absorber and 9-absorber "Hydras". We have also fabricated a version of this detector optimized for lower energies and lower count-rate applications. These devices have a lower superconducting transition temperature and are operated just above the 40mK heat sink temperature. This results in a lower heat capacity and low thermal conductance to the heat sink. With individual single pixels of this type we have achieved a FWHM energy resolution of 0.9 eV with 1.5 keV Al K x-rays, to our knowledge the first x-ray microcalorimeter with sub-eV energy resolution. The 4-absorber and 9-absorber versions of this type achieved FWHM energy resolutions of 1.4 eV and 2.1 eV at 1.5 keV respectively. We will discuss the application of these devices for new astrophysics mission concepts

    Gendering the careers of young professionals: some early findings from a longitudinal study. in Organizing/theorizing: developments in organization theory and practice

    Full text link
    Wonders whether companies actually have employees best interests at heart across physical, mental and spiritual spheres. Posits that most organizations ignore their workforce – not even, in many cases, describing workers as assets! Describes many studies to back up this claim in theis work based on the 2002 Employment Research Unit Annual Conference, in Cardiff, Wales
    • …
    corecore