2,854 research outputs found

    Ageing and moisture uptake in polymethyl methacrylate (PMMA) bone cements

    Get PDF
    Bone cements are extensively employed in orthopaedics for joint arthroplasty, however implant failure in the form of aseptic loosening is known to occur after long-term use. The exact mechanism causing this is not well understood, however it is thought to arise from a combination of fatigue and chemical degradation resulting from the hostile in vivo environment. In this study, two commercial bone cements were aged in an isotonic fluid at physiological temperatures and changes in moisture uptake, microstructure and mechanical and fatigue properties were studied. Initial penetration of water into the cement followed Fickian diffusion and was thought to be caused by vacancies created by leaching monomer. An increase in weight of approximately 2% was experienced after 30 days ageing and was accompanied by hydrolysis of poly(methyl methacrylate) (PMMA) in the outermost layers of the cement. This molecular change and the plasticising effect of water resulted in reduced mechanical and fatigue properties over time. Cement ageing is therefore thought to be a key contributor in the long-term failure of cemented joint replacements. The results from this study have highlighted the need to develop cements capable of withstanding long-term degradation and for more accurate test methods, which fully account for physiological ageing

    TEM Cell Testing of Cable Noise Reduction Techniques From 2 MHz to 200 MHz - Part 1

    Get PDF
    This paper presents empirical results of cable noise reduction techniques as demonstrated in a TEM cell operating with radiated fields from 2 - 200 MHz. It is the first part of a two-paper series. This first paper discusses cable types and shield connections. In the second paper, the effects of load and source resistances and chassis connections are examined. For each topic, well established theories are compared to data from a real-world physical system. Finally, recommendations for minimizing cable susceptibility (and thus cable emissions) are presented. There are numerous papers and textbooks that present theoretical analyses of cable noise reduction techniques. However, empirical data is often targeted to low frequencies (e.g. 100 MHz). Additionally, a comprehensive study showing the relative effects of various noise reduction techniques is needed. These include the use of dedicated return wires, twisted wiring, cable shielding, shield connections, changing load or source impedances, and implementing load- or source-to-chassis isolation. We have created an experimental setup that emulates a real-world electrical system, while still allowing us to independently vary a host of parameters. The goal of the experiment was to determine the relative effectiveness of various noise reduction techniques when the cable is in the presence of radiated emissions from 2 MHz to 200 MHz. The electronic system (Fig. 1) consisted of two Hammond shielded electrical enclosures, one containing the source resistance, and the other containing the load resistance. The boxes were mounted on a large aluminium plate acting as the chassis. Cables connecting the two boxes measured 81 cm in length and were attached to the boxes using standard D38999 military-style connectors. The test setup is shown in Fig. 2. Electromagnetic fields were created using an HP8657B signal generator, MiniCircuits ZHL-42W-SMA amplifier, and an EMCO 5103 TEM cell. Measurements were taken using an Agilent E4401B spectrum analyzer and HP1141a differential probes

    TEM Cell Testing of Cable Noise Reduction Techniques from 2 MHz to 200 MHz -- Part 2

    Get PDF
    This paper presents empirical results of cable noise reduction techniques as demonstrated in a TEM cell operating with radiated fields from 2 - 200 MHz. It is the second part of a two-paper series. The first paper discussed cable types and shield connections. In this second paper, the effects of load and source resistances and chassis connections are examined. For each topic, well established theories are compared to data from a real-world physical system. Finally, recommendations for minimizing cable susceptibility (and thus cable emissions) are presented. There are numerous papers and textbooks that present theoretical analyses of cable noise reduction techniques. However, empirical data is often targeted to low frequencies (e.g. 100 MHz). Additionally, a comprehensive study showing the relative effects of various noise reduction techniques is needed. These include the use of dedicated return wires, twisted wiring, cable shielding, shield connections, changing load or source impedances, and implementing load- or source-to-chassis isolation. We have created an experimental setup that emulates a real-world electrical system, while still allowing us to independently vary a host of parameters. The goal of the experiment was to determine the relative effectiveness of various noise reduction techniques when the cable is in the presence of radiated emissions from 2 MHz to 200 MHz

    Bcar1/p130Cas is essential for ventricular development and neural crest cell remodelling of the cardiac outflow tract.

    Get PDF
    AIM: The adapter protein p130Cas, encoded by the Bcar1 gene, is a key regulator of cell movement, adhesion, and cell cycle control in diverse cell types. Bcar1 constitutive knockout mice are embryonic lethal by embryonic days (E) 11.5-12.5, but the role of Bcar1 in embryonic development remains unclear. Here, we investigated the role of Bcar1 specifically in cardiovascular development and defined the cellular and molecular mechanisms disrupted following targeted Bcar1 deletions. METHODS AND RESULTS: We crossed Bcar1 floxed mice with Cre transgenic lines allowing for cell-specific knockout either in smooth muscle and early cardiac tissues (SM22-Cre), mature smooth muscle cells (smMHC-Cre), endothelial cells (Tie2-Cre), second heart field cells (Mef2c-Cre), or neural crest cells (NCC) (Pax3-Cre) and characterised these conditional knock outs using a combination of histological and molecular biology techniques.Conditional knockout of Bcar1 in SM22-expressing smooth muscle cells and cardiac tissues (Bcar1SM22KO) was embryonically lethal from E14.5-15.5 due to severe cardiovascular defects, including abnormal ventricular development and failure of outflow tract (OFT) septation leading to a single outflow vessel reminiscent of persistent truncus arteriosus. SM22-restricted loss of Bcar1 was associated with failure of OFT cushion cells to undergo differentiation to septal mesenchymal cells positive for SMC-specific α-actin, and disrupted expression of proteins and transcription factors involved in epithelial-to-mesenchymal transformation (EMT). Furthermore, knockout of Bcar1 specifically in NCC (Bcar1PAX3KO) recapitulated part of the OFT septation and aortic sac defects seen in the Bcar1SM22KO mutants, indicating a cell-specific requirement for Bcar1 in NCC essential for OFT septation. In contrast, conditional knockouts of Bcar1 in differentiated smooth muscle, endothelial cells, and second heart field cells survived to term and were phenotypically normal at birth and post-natally. CONCLUSIONS: Our work reveals a cell-specific requirement for Bcar1 in NCC, early myogenic and cardiac cells, essential for OFT septation, myocardialisation and EMT/cell cycle regulation and differentiation to myogenic lineages. TRANSLATIONAL PERSPECTIVE: The molecular pathways coordinating cardiogenesis and the remodelling of the OFT are complex, and dysregulation of these pathways causes human heart defects. Our findings highlight a specific requirement for Bcar1 essential for cardiogenesis. Furthermore, the failure of OFT septation in Bcar1SM22KO mice resembles persistent truncus arteriosus (PTA), a feature of several human congenital heart diseases, including DiGeorge Syndrome. Our findings have implications for the mechanisms underlying the pathogenesis of congenital heart disease, and suggest that mice with conditional Bcar1 deletions may be useful models for dissecting mechanisms involved in the pathogenesis of human heart defects

    Nonlinear scaling effects in the stiffness of soft cellular structures

    Get PDF
    For cellular structures with uniform geometry, cell size and distribution, made from a neo-Hookean material, we demonstrate experimentally that large stretching causes nonlinear scaling effects governed by the microstructural architecture and the large strains at the cell level, which are not predicted by the linear elastic theory. For this purpose, three honeycomb-like structures with uniform square cells in stacked distribution were designed, where the number of cells varied, while the material volume and the ratio between the thickness and the length of the cell walls were fixed. These structures were manufactured from silicone rubber and tested under large uniaxial tension in a bespoke test fixture. Optical strain measurements were used to assess the deformation by capturing both the global displacements of the structure and the local deformations in the form of a strain map. The experimental results showed that, under sufficiently large strains, there was an increase in the stiffness of the structure when the same volume of material was arranged as many small cells compared to when it was organized as fewer larger cells. Finite element simulations confirmed our experimental findings. This study sheds light upon the nonlinear elastic responses of cellular structures in large-strain deformations, which cannot be captured within the linear elasticity framework

    Nonlinear scaling effects in the stiffness of soft cellular structures

    Get PDF
    For cellular structures with uniform geometry, cell size and distribution, made from a neo-Hookean material, we demonstrate experimentally that large stretching causes nonlinear scaling effects governed by the microstructural architecture and the large strains at the cell level, which are not predicted by the linear elastic theory. For this purpose, three honeycomb-like structures with uniform square cells in stacked distribution were designed, where the number of cells varied, while the material volume and the ratio between the thickness and the length of the cell walls were fixed. These structures were manufactured from silicone rubber and tested under large uniaxial tension in a bespoke test fixture. Optical strain measurements were used to assess the deformation by capturing both the global displacements of the structure and the local deformations in the form of a strain map. The experimental results showed that, under sufficiently large strains, there was an increase in the stiffness of the structure when the same volume of material was arranged as many small cells compared to when it was organized as fewer larger cells. Finite element simulations confirmed our experimental findings. This study sheds light upon the nonlinear elastic responses of cellular structures in large-strain deformations, which cannot be captured within the linear elasticity framework

    Generation of cloned transgenic pigs rich in omega-3 fatty acids

    Get PDF
    Meat products are generally low in omega-3 (n-3) fatty acids, which are beneficial to human health. We describe the generation of cloned pigs that express a humanized Caenorhabditis elegans gene, fat-1, encoding an n-3 fatty acid desaturase. The hfat-1 transgenic pigs produce high levels of n-3 fatty acids from n-6 analogs, and their tissues have a significantly reduced ratio of n-6/n-3 fatty acids (P < 0.001). © 2006 Nature Publishing Group

    Euler buckling in red blood cells: An optically driven biological micromotor

    Full text link
    We investigate the physics of an optically-driven micromotor of biological origin. A single, live red blood cell, when placed in an optical trap folds into a rod-like shape. If the trapping laser beam is circularly polarized, the folded RBC rotates. A model based on the concept of buckling instabilities captures the folding phenomenon; the rotation of the cell is simply understood using the Poincar\`e sphere. Our model predicts that (i) at a critical intensity of the trapping beam the RBC shape undergoes large fluctuations and (ii) the torque is proportional to the intensity of the laser beam. These predictions have been tested experimentally. We suggest a possible mechanism for emergence of birefringent properties in the RBC in the folded state
    corecore