11 research outputs found

    Knee Osteoarthritis in Relation to the Risk Factors of the Metabolic Syndrome Components and Environment of Origin

    No full text
    Background: Knee osteoarthritis (KOA) is a chronic degenerative pathology that is associated with multiple risk factors such as age, sex, obesity, or metabolic syndrome (MetS). The present clinical trial aimed to investigate the influence of the environment of origin, body mass index (BMI), and MetS parameters on the KOA differentiated degrees. Methods: 85 patients were admitted for the clinical study. The KOA presence was investigated using X-rays analysis. The Kellgren–Lawrence classification (KL) of the KOA severity and the MetS characteristic parameters using freshly collected blood were performed for each patient. All data collected were used for ANOVA statistic interpretation. Results: The total cholesterol and glycemia were found to be statistically significant (p < 0.028, and p < 0.03, respectively), with a high level in patients with severe KOA compared to healthy ones. Patients from rural regions are 5.18 times more prone to develop severe KOA when compared to ones from urban areas. Conclusions: The results of the statistical analysis confirmed the correlation between the incidence and severity of KOA and the influence of increased values of BMI, glycemia, triglycerides, and total cholesterol. The investigations revealed a statistically significant influence of the environment of origin on the KOA degree of the patients.ISSN:2077-038

    Considerations on the Controlled Delivery of Bioactive Compounds through Hyaluronic Acid Membrane

    No full text
    (1) Background: The standard treatment for periodontal disease, a chronic inflammatory state caused by the interaction between biofilms generated by organized oral bacteria and the local host defense response, consists of calculus and biofilm removal through mechanical debridement, associated with antimicrobial therapy that could be delivered either systemically or locally. The present study aimed to determine the effectiveness of a hyaluronic acid membrane matrix as a carrier for the controlled release of the active compounds of a formulation proposed as a topical treatment for periodontal disease, and the influence of pH on the complex system&rsquo;s stability. (2) Methods: The obtained hyaluronic acid (HA) hydrogel membrane with dispersed melatonin (MEL), metronidazole (MZ), and tetracycline (T) was completely characterized through FTIR, XRD, thermal analysis, UV-Vis and fluorescence spectroscopy, fluorescence microscopy, zeta potential and dielectric analysis. The MTT viability test was applied to check the cytotoxicity of the obtained membranes, while the microbiological assessment was performed against strains of Staphylococcus spp. and Streptococcus spp. The spectrophotometric investigations allowed to follow up the release profile from the HA matrix for MEL, MZ, and T present in the topical treatment considered. We studied the behavior of the active compounds against the pH of the generated environment, and the release profile of the bioactive formulation based on the specific comportment towards pH variation. The controlled delivery of the bioactive compounds using HA as a supportive matrix was modeled applying Korsmeyer&ndash;Peppas, Higuchi, first-order kinetic models, and a newly proposed pseudo-first-order kinetic model. (3) Results: It was observed that MZ and T were released at higher active concentrations than MEL when the pH was increased from 6.75, specific for patients with periodontitis, to a pH of 7.10, characterizing the healthy patients. Additionally, it was shown that for MZ, there is a burst delivery up to 2.40 &times; 10&minus;5 mol/L followed by a release decrease, while for MEL and T a short release plateau was recorded up to a concentration of 1.80 &times; 10&minus;5 mol/L for MEL and 0.90 &times; 10&minus;5 mol/L for T, followed by a continuous release; (4) Conclusions: The results are encouraging for the usage of the HA membrane matrix as releasing vehicle for the active components of the proposed topical treatment at a physiological pH

    Knee Osteoarthritis in Relation to the Risk Factors of the Metabolic Syndrome Components and Environment of Origin

    No full text
    Background: Knee osteoarthritis (KOA) is a chronic degenerative pathology that is associated with multiple risk factors such as age, sex, obesity, or metabolic syndrome (MetS). The present clinical trial aimed to investigate the influence of the environment of origin, body mass index (BMI), and MetS parameters on the KOA differentiated degrees. Methods: 85 patients were admitted for the clinical study. The KOA presence was investigated using X-rays analysis. The Kellgren&ndash;Lawrence classification (KL) of the KOA severity and the MetS characteristic parameters using freshly collected blood were performed for each patient. All data collected were used for ANOVA statistic interpretation. Results: The total cholesterol and glycemia were found to be statistically significant (p &lt; 0.028, and p &lt; 0.03, respectively), with a high level in patients with severe KOA compared to healthy ones. Patients from rural regions are 5.18 times more prone to develop severe KOA when compared to ones from urban areas. Conclusions: The results of the statistical analysis confirmed the correlation between the incidence and severity of KOA and the influence of increased values of BMI, glycemia, triglycerides, and total cholesterol. The investigations revealed a statistically significant influence of the environment of origin on the KOA degree of the patients

    Assessment of the Dynamic Parameters of an Ion-Selective Microsensor

    No full text
    We report the statistical parameters associated with the dynamic characteristics of a calcium microelectrode. The electrochemical behavior of the obtained microsensor was assessed against the main interferents

    Accuracy, Labor-Time and Patient-Reported Outcomes with Partially versus Fully Digital Workflow for Flapless Guided Dental Implants Insertion—A Randomized Clinical Trial with One-Year Follow-Up

    No full text
    (1) Background: Prosthetically-driven implant positioning is a prerequisite for long-term successful treatment. Transferring the planned implant position information to the clinical setting could be done using either static or dynamic guided techniques. The 3D model of the bone and surrounding structures is obtained via cone beam computed tomography (CBCT) and the patient’s oral condition can be acquired conventionally and then digitalized using a desktop scanner, partially digital workflow (PDW) or digitally with the aid of an intraoral scanner (FDW). The aim of the present randomized clinical trial (RCT) was to compare the accuracy of flapless dental implants insertion in partially edentulous patients with a static surgical template obtained through PDW and FDW. Patient outcome and time spent from data collection to template manufacturing were also compared. (2) Methods: 66 partially edentulous sites (at 49 patients) were randomly assigned to a PDW or FDW for guided implant insertion. Planned and placed implants position were compared by assessing four deviation parameters: 3D error at the entry point, 3D error at the apex, angular deviation, and vertical deviation at entry point. (3) Results: A total of 111 implants were inserted. No implant loss during osseointegration or mechanical and technical complications occurred during the first-year post-implants loading. The mean error at the entry point was 0.44 mm (FDW) and 0.85 (PDW), p ≤ 0.00; at implant apex, 1.03 (FDW) and 1.48 (PDW), p ≤ 0.00; the mean angular deviation, 2.12° (FDW) and 2.48° (PDW), p = 0.03 and the mean depth deviation, 0.45 mm (FDW) and 0.68 mm (PDW), p ≤ 0.00; (4) Conclusions: Despite the statistically significant differences between the groups, and in the limits of the present study, full digital workflow as well as partially digital workflow are predictable methods for accurate prosthetically driven guided implants insertion

    The Implication of Reactive Oxygen Species and Antioxidants in Knee Osteoarthritis

    No full text
    Knee osteoarthritis (KOA) is a chronic multifactorial pathology and a current and essential challenge for public health, with a negative impact on the geriatric patient’s quality of life. The pathophysiology is not fully known; therefore, no specific treatment has been found to date. The increase in the number of newly diagnosed cases of KOA is worrying, and it is essential to reduce the risk factors and detect those with a protective role in this context. The destructive effects of free radicals consist of the acceleration of chondrosenescence and apoptosis. Among other risk factors, the influence of redox imbalance on the homeostasis of the osteoarticular system is highlighted. The evolution of KOA can be correlated with oxidative stress markers or antioxidant status. These factors reveal the importance of maintaining a redox balance for the joints and the whole body’s health, emphasizing the importance of an individualized therapeutic approach based on antioxidant effects. This paper aims to present an updated picture of the implications of reactive oxygen species (ROS) in KOA from pathophysiological and biochemical perspectives, focusing on antioxidant systems that could establish the premises for appropriate treatment to restore the redox balance and improve the condition of patients with KO

    Biopolymeric Membrane Enriched with Chitosan and Silver for Metallic Ions Removal

    No full text
    The present paper synthesized, characterized, and evaluated the performance of the novel biopolymeric membrane enriched with cellulose acetate and chitosan (CHI)-silver (Ag) ions in order to remove iron ion from the synthetic wastewater using a new electrodialysis system. The prepared membranes were characterized by Fourier Transforms Infrared Spectroscopy-Attenuated Total Reflection (FTIR-ATR), Thermal Gravimetric Analysis (TGA) and Differential Thermal Analysis (DSC), contact angle measurements, microscopy studies, and electrochemical impedance spectroscopy (EIS). The electrodialysis experiments were performed at the different applied voltages (5, 10, and 15 V) for one hour, at room temperature. The treatment rate (TE) of iron ions, current efficiency (IE), and energy consumption (Wc) were calculated. FTIR-ATR spectra evidenced that incorporation of CHI-Ag ions into the polymer mixture led to a polymer-metal ion complex formation within the membrane. The TGA-DSC analysis for the obtained biopolymeric membranes showed excellent thermal stability (&gt;350 &deg;C). The contact angle measurements demonstrated the hydrophobic character of the polymeric membrane and a decrease of it by CHI-Ag adding. The EIS results indicated that the silver ions induced a higher ionic electrical conductivity. The highest value of the iron ions treatment rate (&gt;60%) was obtained for the biopolymeric membrane with CHI-Ag ions at applied voltage of 15 V
    corecore