47 research outputs found

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS)

    Get PDF
    OBJECTIVES: A second paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 1 July 2019 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-nine hospitals contributed 398 registered implants in 353 patients (150 female, 203 male) to the registry. The most frequent aetiology of heart failure was any form of cardiomyopathy (61%), followed by congenital heart disease and myocarditis (16.4% and 16.1%, respectively). Competing outcomes analysis revealed that a total of 80% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 20% died while on support. At 12 months, 46.7% received transplants, 8.7% were weaned from their device and 18.5% died. The 3-month adverse events rate was 1.69 per patient-year for device malfunction including pump exchange, 0.48 for major bleeding, 0.64 for major infection and 0.78 for neurological events. CONCLUSIONS: The overall survival rate was 81.5% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age) (P = 0.01) and lower weight (<20 kg) (P = 0.015). Transplant rates at 6 months contin

    High proportion of genetic cases in patients with advanced cardiomyopathy including a novel homozygous Plakophilin 2-gene mutation

    Get PDF
    Cardiomyopathies might lead to end-stage heart disease with the requirement of drastic treatments like bridging up to transplant or heart transplantation. A not precisely known proportion of these diseases are genetically determined. We genotyped 43 index-patients (30 DCM, 10 ARVC, 3 RCM) with advanced or end stage cardiomyopathy using a gene panel which covered 46 known cardiomyopathy disease genes. Fifty-three variants with possible impact on disease in 33 patients were identified. Of these 27 (51%) were classified as likely pathogenic or pathogenic in the MYH7, MYL2, MYL3, NEXN, TNNC1, TNNI3, DES, LMNA, PKP2, PLN, RBM20, TTN, and CRYAB genes. Fifty-six percent (n = 24) of index-patients carried a likely pathogenic or pathogenic mutation. Of these 75% (n = 18) were familial and 25% (n = 6) sporadic cases. However, severe cardiomyopathy seemed to be not characterized by a specific mutation profile. Remarkably, we identified a novel homozygous PKP2-missense variant in a large consanguineous family with sudden death in early childhood and several members with heart transplantation in adolescent age

    Antithrombotic therapy in pediatric ventricular assist devices: Multicenter survey of the European EXCOR Pediatric Investigator Group

    Get PDF
    Objectives: Mechanical circulatory support for pediatric heart failure patients with the Berlin Heart EXCOR ventricular assist system is the only approved and established bridging strategy for recovery or heart transplantation. In recent years, the burden of thromboembolic events has led to modifications of the recommended antithrombotic therapy. Therefore, we aimed to assess modifications of antithrombotic practice among the European EXCOR Pediatric Investigator Group members. Methods: We sent a questionnaire assessing seven aspects of antithrombotic therapy to 18 European hospitals using the EXCOR device for children. Returned questionnaires were analyzed and identified antithrombotic strategies were descriptively compared to “Edmonton protocol” recommendations developed for the US EXCOR pediatric approval study. Results: Analysis of 18 received surveys revealed substantial deviations from the Edmonton protocol, including earlier start of heparin therapy at 6–12 h postoperatively and in 50% of surveyed centers, monitoring of heparin effectiveness with aPTT assay, administering vitamin K antagonists before 12 months of age. About 39% of centers use higher international normalized ratio targets, and platelet inhibition is changed in 56% including the use of clopidogrel instead of dipyridamole. Significant inter-center variability with multiple deviations from the Edmonton protocol was discovered with only one center following the Edmonton protocol completely. Conclusion: Current antithrombotic practice among European EXCOR users representing the treatment of more than 600 pediatric patients has changed over time with a trend toward a more aggressive therapy. There is a need for systematic evidence-based evaluation and harmonization of developmentally adjusted antithrombotic management practices in prospective studies toward revised recommendations

    ECMO for Cardiac Rescue after Accidental Intravenous Mepivacaine Application

    Get PDF
    Mepivacaine is a potent local anaesthetic and used for infiltration and regional anaesthesia in adults and pediatric patients. Intoxications with mepivacaine affect mainly the CNS and the cardiovascular system. We present a case of accidental intravenous mepivacaine application and intoxication of an infant resulting in seizure, broad complex bradyarrhythmia, arterial hypotension and finally cardiac arrest. The patient could be rescued by prolonged resuscitations and a rapid initiation of ECMO and survived without neurological damage. The management strategies of this rare complication including promising other treatment options with lipid emulsions are discussed
    corecore