26 research outputs found

    Excellent results with the cemented Lubinus SP II 130-mm femoral stem at 10 years of follow-up

    Get PDF
    Background and purpose - The Lubinus SP II stem is well documented in both orthopedic registries and clinical studies. Worldwide, the most commonly used stem lengths are 150 mm and 170 mm. In 1995, the 130-mm stem was introduced, but no outcome data have been published. We assessed the long-term survival of the Lubinus SP II 130-mm stem in primary total hip arthroplasty.Patients and methods - In a retrospective cohort study, we evaluated 829 patients with a Lubinus SP II primary total hip arthroplasty (932 hips). The hips were implanted between 1996 and 2001. The primary endpoint was revision for any reason. The mean follow-up period was 10 (5-15) years.Results - Survival analysis showed an all-cause 10-year survival rate of the stem of 98.7% (95% CI: 99.7-97.7), and all-cause 10-year survival of the total hip arthroplasty was 98.3% (95% CI: 99.3-97.3).Interpretation - Excellent long-term results can be achieved with the cemented Lubinus SP II with the relatively short 130-mm stem. This stem has potential advantages over its 150-mm and 170-mm siblings such as bone preservation distal to the stem, better proximal filling around the prosthesis, and easier removal.</p

    Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study

    Get PDF
    Purpose: Quantification of the effect of O-MAR on decreasing metal artefacts caused by large head metal on metal total hip arthroplasty (MoM THA) in a dedicated phantom setup of the hip. Background: Pathological reactions of the hip capsule on Computed tomography (CT) can be difficult to diagnose due to different metal artefacts. The O-MAR algorithm deploys an iterative loop where the metal sinogram is identified, extracted, and subsequently serves as a mask to correct the measured sinogram. Main goal of this study is to quantify the ability of the O-MAR technique to correct deviation in medullary bone attenuation caused by streak artefacts from the large-head MoM THA embedded in a phantom. Secondary goal is to evaluate the influence of O-MAR on CNR. Methods: The phantom was designed as a Perspex box (PMMA) containing water and a supplementary MOM THA surrounded by Perspex columns comprising calibrated calcium pellets. Each column contains 200 mg of hydroxyapatite/calcium carbonate to simulate healthy bone tissue. Scans were obtained with and without a MoM THA at different dose levels. Different reconstructions were made with filter A, iDose(4) level 5 and with and without O-MAR. The scans without the prosthesis were used as the baseline. Information about the attenuation in Hounsfield units, image noise in standard deviation within the ROI's were extracted and the CNR was calculated. Results: Pellet L0 and R0 (proximal of the MoM THA) were defined as reference, lacking any disturbance by metal artefacts; L5, L6 and L8 were respectively visually categorized as 'light' 'medium' and 'heavy disturbance'. Significant improvements in attenuation deviation caused by metal artefact were 43, 68 and 32 %, for respectively pellet L5, L6 and L8 (p <0.001). Significant CNR improvements were present for L5 and L6 and were respectively 72 and 52 % (p <0.001). O-MAR showed no improvement on CNR for L8. Conclusion: This phantom study significantly increases image quality by the use of O-MAR in the presence of metal artefacts by significantly reducing metal artefacts subsequently and increasing CNR on a 64 slice CT system in light and medium disturbance of the imag

    No clinically relevant difference in patient-reported outcomes between the direct superior approach and the posterolateral or anterior approach for primary total hip arthroplasty:analysis of 37,976 primary hip arthroplas-ties in the Dutch Arthroplasty Registry

    Get PDF
    Background and purpose — The direct superior approach (DSA) is a modification of the posterolateral approach (PLA) for total hip arthroplasty (THA). Patient-reported outcome measures (PROMs) of the DSA have not been investigated previously using nationwide data. Our aim was to assess PROMs after THA using the DSA compared with the PLA and, secondarily, with the anterior approach (DAA). Patients and methods — In this population-based cohort study we included 37,976 primary THAs performed between 2014 and 2020 (PLA: n = 22,616; DAA: n = 15,017; DSA: n = 343) using Dutch Arthroplasty Registry data. PROMs (NRS pain, EQ-5D, HOOS-PS, and OHS) were mea-sured preoperatively, and at 3 and 12 months postoperatively. Repeated measurements were analyzed using mixed-effects models, adjusted for confounders, to investigate the associa-tion between surgical approach and PROMs over time. Results — From baseline to 3 and 12 months, improve-ments for NRS pain scores, EQ-5D, and OHS were com-parable for the DSA compared with the PLA or DAA. No difference was found in HOOS-PS improvement 3 months postoperatively between DSA and PLA (–0.2, 95% confidence interval [CI] –2.4 to 1.9) and between DSA and DAA (–1.7, CI –3.9 to 0.5). At 12 months postoperatively, patients in the DSA group had improved –2.8 points (CI –4.9 to –0.6) more in HOOS-PS compared with the DAA, but not with the PLA group (–1.0, CI –3.2 to 1.1). Conclusion — Our study showed no clinically meaning-ful differences between the DSA and either PLA or DAA.</p

    No clinically relevant difference in patient-reported outcomes between the direct superior approach and the posterolateral or anterior approach for primary total hip arthroplasty:analysis of 37,976 primary hip arthroplas-ties in the Dutch Arthroplasty Registry

    Get PDF
    Background and purpose — The direct superior approach (DSA) is a modification of the posterolateral approach (PLA) for total hip arthroplasty (THA). Patient-reported outcome measures (PROMs) of the DSA have not been investigated previously using nationwide data. Our aim was to assess PROMs after THA using the DSA compared with the PLA and, secondarily, with the anterior approach (DAA). Patients and methods — In this population-based cohort study we included 37,976 primary THAs performed between 2014 and 2020 (PLA: n = 22,616; DAA: n = 15,017; DSA: n = 343) using Dutch Arthroplasty Registry data. PROMs (NRS pain, EQ-5D, HOOS-PS, and OHS) were mea-sured preoperatively, and at 3 and 12 months postoperatively. Repeated measurements were analyzed using mixed-effects models, adjusted for confounders, to investigate the associa-tion between surgical approach and PROMs over time. Results — From baseline to 3 and 12 months, improve-ments for NRS pain scores, EQ-5D, and OHS were com-parable for the DSA compared with the PLA or DAA. No difference was found in HOOS-PS improvement 3 months postoperatively between DSA and PLA (–0.2, 95% confidence interval [CI] –2.4 to 1.9) and between DSA and DAA (–1.7, CI –3.9 to 0.5). At 12 months postoperatively, patients in the DSA group had improved –2.8 points (CI –4.9 to –0.6) more in HOOS-PS compared with the DAA, but not with the PLA group (–1.0, CI –3.2 to 1.1). Conclusion — Our study showed no clinically meaning-ful differences between the DSA and either PLA or DAA.</p

    Dutch orthopedic thromboprophylaxis: a 5-year follow-up survey

    Get PDF
    Background and purpose Previous surveys in the Netherlands have revealed that guidelines regarding orthopedic thromboprophylaxis were not followed and that a wide variation in protocols exists. This survey was performed to assess the current use of thromboprophylactic modalities and to compare it with the results of a previous survey

    European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing.

    Get PDF
    Summary Introduction There is an ongoing debate about the optimal use of metal-on-metal (MoM) bearings in total hip replacement, since there are uncertainties about local and systemic adverse effects due to wear and corrosion of these bearings. Despite various national recommendations, efforts to achieve international harmonization of specific evidence-based recommendations for best practice are still lacking. Hypothesis An international consensus study group should be able to develop recommendations on the use and monitoring of MoM bearings, preferably at the European level, through a multidisciplinary approach, by integrating the perspectives of various stakeholders. Materials and methods Twenty-one experts representing three stakeholder groups and eight countries participated in this European consensus study, which consisted of a consensus meeting, subsequent structured discussion, and consensus voting. Results The current statement defines first of all benefits, local and systemic risks, as well as uncertain issues related to MoM bearings. Safety assessment after implantation of MoM comprises all patients. A closer follow-up is recommended for large head MoM (≥ 36 mm) and resurfacing. In these implants basic follow-up should consist of x-rays and metal ion measurement of cobalt in whole blood, performed with GF-AAS or ICP-MS. Clinical and/or radiographic abnormality as well as elevated ion levels needs additional imaging (ultrasound, CT-scan and/or MARS-MRI). Cobalt values less than 2 μg/L are probably devoid of clinical concern, the threshold value for clinical concern is expected to be within the range of 2–7 μg/L. Discussion This is the first multinational, interdisciplinary, and multiprofessional approach for developing a recommendation for the use and monitoring of MoM bearings in total hip replacement. The current recommendations are in partial agreement with previous statements regarding the extent of follow-up and imaging techniques. They however differ from previous communications regarding measurement of metal ions and especially the investigated medium, technique, and eventual threshold levels. Level of evidence Level V, expert opinion/agreement conference

    Dutch guideline on total hip prosthesis

    Get PDF
    Contains fulltext : 97840.pdf (publisher's version ) (Open Access

    Symptomatic venous thromboembolism after trauma surgery – a study on 56.884 procedures

    No full text
    Introduction: Patients undergoing trauma surgery are at significant risk for developing thromboembolism. Venous thromboembolism rates, especially after less common surgical procedures are unknown. The purpose of this study is to establish data on the incidence of venous thromboembolism in trauma practice following a surgical procedure. Methods: All surgical trauma procedures between 2006 and 2011 were identified within the Achmea Health Database. This database records medical care to persons insured at the Achmea health insurance company. This is the largest health insurance company in the Netherlands. In the year following the surgical procedure we analyzed if a claim was filed concerning a deep venous thrombosis or pulmonary embolism. Results: 56.884 surgical trauma procedures were included in the analysis and followed for one year thereafter. Venous thromboembolism development was raised most markedly until 100 days after the surgical procedure. Relatively high incidences of venous thromboembolism were found after surgical lower extremity and pelvic procedures. Conclusions: The present large database study provides a comprehensive view on the epidemiology of venous thromboembolism after different traumatic injuries requiring a surgical procedure

    Mid-term results of cemented hip arthroplasties through the direct anterior approach in the lateral decubitus position: a retrospective cohort study

    No full text
    Abstract Background Reports show a high complication rate when starting with the Direct Anterior Approach (DAA) in a supine position for hip arthroplasty. The DAA with the patient in lateral decubitus position may avoid this problem because it supposedly provides better visibility, especially on the femoral side. However, this approach did show a rather high complication rate during the adoption of the approach at 1 year follow up in our previous report. We were interested what the overall 7 year survival estimate would be and whether improvement could be seen with growing experience. Methods A cohort of patients undergoing total hip arthroplasty right from the start of applying the DAA in lateral decubitus position was analysed. Results In total 175 hip prostheses (162 patients) were evaluated. The 7-year survival estimate was 95.1%, 95 CI: 91.8–98.4%. In 6 of 8 revisions there was aseptic loosening of the stem. By dividing the cohort into 3 consecutive groups in time we did not see a significantly improving revision rate. Conclusions In our experience, the adoption of the direct anterior approach in lateral decubitus position caused a relatively low 7-year survival estimate without an apparent decrease with growing experience, however given the low number of cases further research is needed to investigate the long-term risk of adopting a new approach

    Factors that influence femoral neck length. Analysis of 1543 patients with advanced osteoarthritis of the hip

    No full text
    <p>Background and purpose: There is little known about the relationship between patient characteristic and the variance in geometrical properties of the femoral neck. The length of the femoral neck is relevant when considering a femoral neck preserving hip replacement. Based on surgical experience we hypothesised that femoral neck length (FNL) decreased with age. We investigated whether certain patient characteristics were related to FNL and the femoral head diameter/FNL ratio.</p><p>Patients and methods: The femoral neck length of 1543 patients with osteoarthritis grade 3 and 4 was measured on calibrated pelvic radiographs.</p><p>Results: Increasing age and height were associated positively, while increasing CCD angle and femoral head diameter were associated negatively with femoral neck length. Female gender and height were associated negatively and CCD angle positively with the femoral head diameter/FNL ratio. The FNL in 10 year older individuals was on average 0.2 mm (1%) longer Moreover, every 10 extra degrees in CCD coincided with a neck length decrease of 1.5 mm (8%) in our population.</p><p>Interpretation: It seems justified to conclude that age is not a clinical relevant factor in the indication for femoral neck preserving hip arthroplasty. In this respect, CCD angle seems the most clinical relevant factor. Severe valgus angled hips are not a very suitable indication for femoral neck preserving prosthesis.</p>
    corecore