18 research outputs found

    MRI-based Quantification of Optic Nerve Tortuosity and Subarachnoid Space 3D Geometry: Reliability Assessment

    Get PDF
    In some astronauts, long-duration space flight results in ophthalmic structure changes such as optic nerve (ON) kinking, ON distention, and globe flattening. Assessment of the ON and ON sheath (ONS) may provide insight into the mechanisms responsible for ophthalmic structure changes seen in a subset of astronauts. Automated and manual methods were developed to quantify 3D ON/ONS geometry and ON tortuosity

    Hydrostatic pressure does not cause detectable changes to survival of human retinal ganglion

    Get PDF
    Purpose: Elevated intraocular pressure (IOP) is a major risk factor for glaucoma. One consequence of raised IOP is that ocular tissues are subjected to increased hydrostatic pressure (HP). The effect of raised HP on stress pathway signaling and retinal ganglion cell (RGC) survival in the human retina was investigated. Methods: A chamber was designed to expose cells to increased HP (constant and fluctuating). Accurate pressure control (10-100mmHg) was achieved using mass flow controllers. Human organotypic retinal cultures (HORCs) from donor eyes (<24h post mortem) were cultured in serum-free DMEM/HamF12. Increased HP was compared to simulated ischemia (oxygen glucose deprivation, OGD). Cell death and apoptosis were measured by LDH and TUNEL assays, RGC marker expression by qRT-PCR (THY-1) and RGC number by immunohistochemistry (NeuN). Activated p38 and JNK were detected by Western blot. Results: Exposure of HORCs to constant (60mmHg) or fluctuating (10-100mmHg; 1 cycle/min) pressure for 24 or 48h caused no loss of structural integrity, LDH release, decrease in RGC marker expression (THY-1) or loss of RGCs compared with controls. In addition, there was no increase in TUNEL-positive NeuN-labelled cells at either time-point indicating no increase in apoptosis of RGCs. OGD increased apoptosis, reduced RGC marker expression and RGC number and caused elevated LDH release at 24h. p38 and JNK phosphorylation remained unchanged in HORCs exposed to fluctuating pressure (10-100mmHg; 1 cycle/min) for 15, 30, 60 and 90min durations, whereas OGD (3h) increased activation of p38 and JNK, remaining elevated for 90min post-OGD. Conclusions: Directly applied HP had no detectable impact on RGC survival and stress-signalling in HORCs. Simulated ischemia, however, activated stress pathways and caused RGC death. These results show that direct HP does not cause degeneration of RGCs in the ex vivo human retina

    Mathematical Models of Cardiac Cells Arrangements: The Bidomain Model

    No full text

    Numerical Methods for the Bidomain and Reduced Models

    No full text

    Mathematical Models of Cellular Bioelectrical Activity

    No full text

    Basic Cardiac Anatomy and Electrocardiology

    No full text
    corecore