137 research outputs found

    Engineering meniscus structure and function via multi-layered mesenchymal stem cell-seeded nanofibrous scaffolds

    Get PDF
    Despite advances in tissue engineering for the knee meniscus, it remains a challenge to match the complex macroscopic and microscopic structural features of native tissue, including the circumferentially and radially aligned collagen bundles essential for mechanical function. To mimic this structural hierarchy, this study developed multi-lamellar mesenchymal stem cell (MSC)-seeded nanofibrous constructs. Bovine MSCs were seeded onto nanofibrous scaffolds comprised of poly(ε-caprolactone) with fibers aligned in a single direction (0° or 90° to the scaffold long axis) or circumferentially aligned (C). Multi-layer groups (0°/0°/0°, 90°/90°/90°, 0°/90°/0°, 90°/0°/90°, and C/C/C) were created and cultured for a total of 6 weeks under conditions favoring fibrocartilaginous tissue formation. Tensile testing showed that 0° and C single layer constructs had stiffness values several fold higher than 90° constructs. For multi-layer groups, the stiffness of 0°/0°/0° constructs was higher than all other groups, while 90°/90°/90° constructs had the lowest values. Data for collagen content showed a general positive interactive effect for multi-layers relative to single layer constructs, while a positive interaction for stiffness was found only for the C/C/C group. Collagen content and cell infiltration occurred independent of scaffold alignment, and newly formed collagenous matrix followed the scaffold fiber direction. Structural hierarchies within multi-lamellar constructs dictated biomechanical properties, and only the C/C/C constructs with non-orthogonal alignment within layers featured positive mechanical reinforcement as a consequence of the layered construction. These multi-layer constructs may serve as functional substitutes for the meniscus as well as test beds to understand the complex mechanical principles that enable meniscus function

    Arthroscopic washout of the ankle for septic arthritis in a three-month-old boy

    Get PDF
    There is no report of athroscopic treatment for septic arthritis of the ankle in infants. We report a case of successful management of septic arthritis of the ankle in a three-month-old boy by arthroscopic washout. Arthroscopic washout may be a useful treatment for septic arthritis in young infants when performed early after onset

    Systemic aminoglycosides-induced vestibulotoxicity in humans

    No full text
    Objectives: This systematic review aimed to investigate the prevalence and characteristics of vestibular adverse effects of aminoglycoside (AG) therapy in humans and to analyze objective vestibular tests for the detection of AG-induced vestibulotoxicity. Design: PubMed, Cochrane Database, Web of Science, and reference lists of all included studies were screened by two independent researchers. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed. Studies were included according to preset inclusion criteria and reported outcomes of studies evaluating vestibular function using one or more objective vestibular function tests in adults and children after systemic AG administration. The methodological quality of each study was assessed using the quality assessment tool for quantitative studies. Interrater reliability was established using Cohen's Kappa. Results: Twenty-seven studies were included, with the vast majority showing AG-induced vestibulotoxic side effects, ranging from 0 to 60%. Most studies reported AG-induced abnormalities by caloric and rotatory testing, whereas only a few studies reported using video Head Impulse test and vestibular evoked myogenic potential testing. Conclusions: Because type I hair cells (particularly of the semicircular canals) are more susceptible to ototoxicity, video Head Impulse test and vestibular evoked myogenic potential testing seem more promising for the early detection of vestibulotoxicity than caloric and rotatory testing. Prospective studies using an extensive vestibular test battery are needed to further characterize the impact of AGs on the different vestibular end organs and to identify the most sensitive vestibular technique for the early detection of vestibulotoxicity

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Bacterial Arthritis in the Neurosurgical Patient

    No full text

    Septic arthritis

    No full text
    corecore