19 research outputs found

    Feasibility of real-time three-dimensional stress echocardiography: pharmacological and semi-supine exercise

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Real time three dimensional (RT3D) echocardiography is an accurate and reproducible method for assessing left ventricular shape and function.</p> <p>Aim</p> <p>assess the feasibility and reproducibility of RT3D stress echocardiography (SE) (exercise and pharmacological) in the evaluation of left ventricular function compared to 2D.</p> <p>Methods and results</p> <p>One hundred eleven patients with known or suspected coronary artery disease underwent 2D and RT3DSE. The agreement in WMSI, EDV, ESV measurements was made off-line.</p> <p>The feasibility of RT-3DSE was 67%. The inter-observer variability for WMSI by RT3D echo was higher during exercise and with suboptimal quality images (good: k = 0.88; bad: k = 0.69); and with high heart rate both for pharmacological (HR < 100 bpm, k = 0.83; HR ≥ 100 bpm, k = 0.49) and exercise SE (HR < 120 bpm, k = 0.88; HR ≥ 120 bpm, k = 0.78). The RT3D reproducibility was high for ESV volumes (0.3 ± 14 ml; CI 95%: -27 to 27 ml; p = n.s.).</p> <p>Conclusions</p> <p>RT3DSE is more vulnerable than 2D due to tachycardia, signal quality, patient decubitus and suboptimal resting image quality, making exercise RT3DSE less attractive than pharmacological stress.</p

    The impact of carotid plaque presence and morphology on mortality outcome in cardiological patients

    Get PDF
    BACKGROUND: Carotid plaque severity and morphology can affect cardiovascular prognosis. We evaluate both the importance of echographically assessed carotid artery plaque geometry and morphology as predictors of death in hospitalised cardiological patients. METHODS: 541 hospitalised patients admitted in a cardiological division (age = 66 ± 11 years, 411 men), have been studied through ultrasound Duplex carotid scan and successively followed-up for a median of 34 months. Echo evaluation assessed plaque severity and morphology (presence of heterogeneity and profile). RESULTS: 361 patients showed carotid stenosis (67% with <50% stenosis, 18% with 50–69% stenosis, 9% with >70% stenosis, 4% with near occlusion and 2% with total occlusion). During the follow-up period, there were 83 all-cause deaths (15% of the total population). Using Cox's proportional hazard model, age (RR 1.06, 95% CI 1.03–1.09, p = 0.000), ejection fraction > 50% (RR = 0.62, 95% CI 0.4–0.96, p = 0.03), treatment with statins (RR = 0.52, 95% CI 0.29–0.95, p = 0.34) and the presence of a heterogeneous plaque (RR 1.6; 95% CI, 1.2 to 2.14, p = 0.002) were independent predictors of death. Kaplan – Meier survival estimates have shown the best outcome in patients without plaque, intermediate in patients with homogeneous plaques and the worst outcome in patients with heterogeneous plaques (90% vs 79% vs 73%, p = 0.0001). CONCLUSION: In hospitalised cardiological patients, carotid plaque presence and morphology assessed by ultrasound are independent predictors of death

    Arterial pressure changes monitoring with a new precordial noninvasive sensor

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recently, a cutaneous force-frequency relation recording system based on first heart sound amplitude vibrations has been validated. A further application is the assessment of Second Heart Sound (S2) amplitude variations at increasing heart rates. The aim of this study was to assess the relationship between second heart sound amplitude variations at increasing heart rates and hemodynamic changes.</p> <p>Methods</p> <p>The transcutaneous force sensor was positioned in the precordial region in 146 consecutive patients referred for exercise (n = 99), dipyridamole (n = 41), or pacing stress (n = 6). The curve of S2 peak amplitude variation as a function of heart rate was computed as the increment with respect to the resting value.</p> <p>Results</p> <p>A consistent S2 signal was obtained in all patients. Baseline S2 was 7.2 ± 3.3 m<it>g</it>, increasing to 12.7 ± 7.7 m<it>g </it>at peak stress. S2 percentage increase was + 133 ± 104% in the 99 exercise, + 2 ± 22% in the 41 dipyridamole, and + 31 ± 27% in the 6 pacing patients (p < 0.05). Significant determinants of S2 amplitude were blood pressure, heart rate, and cardiac index with best correlation (R = .57) for mean pressure.</p> <p>Conclusion</p> <p>S2 recording quantitatively documents systemic pressure changes.</p

    Economic analysis including long-term risks and costs of alternative diagnostic strategies to evaluate patients with chest pain

    Get PDF
    Background: Diagnosis costs for cardiovascular disease waste a large amount of healthcare resources. The aim of the study is to evaluate the clinical and economic outcomes of alternative diagnostic strategies in low risk chest pain patients. Methods: We evaluated direct and indirect downstream costs of 6 strategies: coronary angiography (CA) after positive troponin I or T (cTn-I or cTnT) (strategy 1); after positive exercise electrocardiography (ex-ECG) (strategy 2); after positive exercise echocardiography (ex-Echo) (strategy 3); after positive pharmacologic stress echocardiography (PhSE) (strategy 4); after positive myocardial exercise stress single-photon emission computed tomography with technetium Tc 99m sestamibi (ex-SPECT-Tc) (strategy 5) and direct CA (strategy 6). Results: The predictive accuracy in correctly identifying the patients was 83,1% for cTn-I, 87% for cTn-T, 85,1% for ex-ECG, 93,4% for ex-Echo, 98,5% for PhSE, 89,4% for ex-SPECT-Tc and 18,7% for CA. The cost per patient correctly identified results 2.051forcTnI,2.051 for cTn-I, 2.086 for cTn-T, 1.890forexECG,1.890 for ex-ECG, 803 for ex-Echo, 533forPhSE,533 for PhSE, 1.521 for ex-SPECT-Tc (1.634includingcostofextrariskofcancer)and1.634 including cost of extra risk of cancer) and 29.673 for CA ($29.999 including cost of extra risk of cancer). The average relative cost-effectiveness of cardiac imaging compared with the PhSE equal to 1 (as a cost comparator), the relative cost of ex-Echo is 1.5×, of a ex-SPECT-Tc is 3.1×, of a ex-ECG is 3.5×, of cTnI is ×3.8, of cTnT is ×3.9 and of a CA is 56.3×. Conclusion: Stress echocardiography based strategies are cost-effective versus alternative imaging strategies and the risk and cost of radiation exposure is void

    The diagnostic accuracy of pharmacological stress echocardiography for the assessment of coronary artery disease: a meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recent American Heart Association/American College of Cardiology guidelines state that "dobutamine stress echo has substantially higher sensitivity than vasodilator stress echo for detection of coronary artery stenosis" while the European Society of Cardiology guidelines and the European Association of Echocardiography recommendations conclude that "the two tests have very similar applications". Who is right?</p> <p>Aim</p> <p>To evaluate the diagnostic accuracy of dobutamine versus dipyridamole stress echocardiography through an evidence-based approach.</p> <p>Methods</p> <p>From PubMed search, we identified all papers with coronary angiographic verification and head-to-head comparison of dobutamine stress echo (40 mcg/kg/min ± atropine) versus dipyridamole stress echo performed with state-of-the art protocols (either 0.84 mg/kg in 10' plus atropine, or 0.84 mg/kg in 6' without atropine). A total of 5 papers have been found. Pooled weight meta-analysis was performed.</p> <p>Results</p> <p>the 5 analyzed papers recruited 435 patients, 299 with and 136 without angiographically assessed coronary artery disease (quantitatively assessed stenosis > 50%). Dipyridamole and dobutamine showed similar accuracy (87%, 95% confidence intervals, CI, 83–90, vs. 84%, CI, 80–88, p = 0.48), sensitivity (85%, CI 80–89, vs. 86%, CI 78–91, p = 0.81) and specificity (89%, CI 82–94 vs. 86%, CI 75–89, p = 0.15).</p> <p>Conclusion</p> <p>When state-of-the art protocols are considered, dipyridamole and dobutamine stress echo have similar accuracy, specificity and – most importantly – sensitivity for detection of CAD. European recommendations concluding that "<it>dobutamine and vasodilators (at appropriately high doses) are equally potent ischemic stressors for inducing wall motion abnormalities in presence of a critical coronary artery stenosis</it>" are evidence-based.</p

    Post-exercise contractility, diastolic function, and pressure: Operator-independent sensor-based intelligent monitoring for heart failure telemedicine

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>New sensors for intelligent remote monitoring of the heart should be developed. Recently, a cutaneous force-frequency relation recording system has been validated based on heart sound amplitude and timing variations at increasing heart rates.</p> <p>Aim</p> <p>To assess sensor-based post-exercise contractility, diastolic function and pressure in normal and diseased hearts as a model of a wireless telemedicine system.</p> <p>Methods</p> <p>We enrolled 150 patients and 22 controls referred for exercise-stress echocardiography, age 55 ± 18 years. The sensor was attached in the precordial region by an ECG electrode. Stress and recovery contractility were derived by first heart sound amplitude vibration changes; diastolic times were acquired continuously. Systemic pressure changes were quantitatively documented by second heart sound recording.</p> <p>Results</p> <p>Interpretable sensor recordings were obtained in all patients (feasibility = 100%). Post-exercise contractility overshoot (defined as increase > 10% of recovery contractility vs exercise value) was more frequent in patients than controls (27% vs 8%, p < 0.05). At 100 bpm stress heart rate, systolic/diastolic time ratio (normal, < 1) was > 1 in 20 patients and in none of the controls (p < 0.01); at recovery systolic/diastolic ratio was > 1 in only 3 patients (p < 0.01 vs stress). Post-exercise reduced arterial pressure was sensed.</p> <p>Conclusion</p> <p>Post-exercise contractility, diastolic time and pressure changes can be continuously measured by a cutaneous sensor. Heart disease affects not only exercise systolic performance, but also post-exercise recovery, diastolic time intervals and blood pressure changes – in our study, all of these were monitored by a non-invasive wearable sensor.</p

    Consistent improvement with eculizumab across muscle groups in myasthenia gravis

    Get PDF
    corecore