14 research outputs found

    Serial Assessment of Vessel Interactions After Drug-Eluting Stent Implantation in Unprotected Distal Left Main Coronary Artery Disease Using Frequency-Domain Optical Coherence Tomography

    Get PDF
    ObjectivesThis study sought to assess stent-vessel interactions after drug-eluting stent (DES) implantation in unprotected left main coronary artery (ULM) by frequency-domain optical coherence tomography (FD-OCT).BackgroundPercutaneous coronary intervention using DES in ULM has been increasingly performed in routine practice. Recently, FD-OCT assessments of DES-vessel interactions have been used as surrogates for DES safety; however, there are no FD-OCT studies in ULM.MethodsWe prospectively enrolled 33 consecutive patients with ULM disease treated with sirolimus- (n = 11) and everolimus-eluting stents (n = 22). FD-OCT assessments were performed post-percutaneous coronary intervention and at 9-month follow-up. Three different segments of ULM were compared: distal (DIS), bifurcation (BIF), and ostial-body (BODY). The primary endpoints were percentages of uncovered and malapposed struts at 9-month follow-up, and the secondary endpoint was neointimal hyperplasia area.ResultsWe analyzed 25,873 stent struts. Significant differences were demonstrated for percentage of uncovered struts (3.4%, 11.7%, and 18.7%, respectively for DIS, BIF, and BODY; p < 0.05 for all the comparisons). Malapposition was also more common in BODY (5.3%) than in DIS (0.6%) and BIF (2.0%) segments (p < 0.05 for BODY vs. DIS, and BODY vs. BIF). Equivalent neointimal hyperplasia areas were demonstrated in all segments. Acute malapposition rates led to different patterns of DES-vessel interactions at 9-month follow-up.ConclusionsDistinct patterns of DES-vessel interactions were demonstrated in different segments of ULM. Acute stent strut malapposition affects these findings

    MOESM1 of Use of cardiovascular magnetic resonance in the evaluation of a giant right atrial appendage aneurysm: a case report and review of the literature

    No full text
    Additional file 1. Balanced turbo field-echo cine in short axis view. The size and position of the right atrial appendage aneurysm is shown in relation to the right ventricle. Note how the right atrial appendage aneurysm compresses and deforms the right ventricle throughout the cardiac cycle

    Impact of Neointimal Calcifications on Acute Stent Performance during the Treatment of In-Stent Restenosis

    No full text
    Abstract Optical coherence tomography (OCT) has become the invasive imaging modality of choice for coronary stent assessment due to its unmatched spatial resolution. Neointimal calcification (NC) is a rare finding, observed in 5-10% of in-stent restenosis (ISR) neointima. The impact of NC on percutaneous coronary intervention of ISR is unknown. We therefore present the outcome of six unique cases of ISR and NC in which OCT was used to evaluate the impact of NC on the quality of stent-in-stent deployment for the treatment of ISR. This series demonstrates for the first time the impact of NC on stent expansion, a finding which might help guiding percutaneous coronary intervention for ISR with NC
    corecore