28 research outputs found

    Fully automatic algorithm for detecting and tracking anatomical shoulder landmarks on fluoroscopy images with artificial intelligence.

    Get PDF
    OBJECTIVE Patients with rotator cuff tears present often with glenohumeral joint instability. Assessing anatomic angles and shoulder kinematics from fluoroscopy requires labelling of specific landmarks in each image. This study aimed to develop an artificial intelligence model for automatic landmark detection from fluoroscopic images for motion tracking of the scapula and humeral head. MATERIALS AND METHODS Fluoroscopic images were acquired for both shoulders of 25 participants (N = 12 patients with unilateral rotator cuff tear, 6 men, mean (standard deviation) age: 63.7 ± 9.7 years; 13 asymptomatic subjects, 7 men, 58.2 ± 8.9 years) during a 30° arm abduction and adduction movement in the scapular plane with and without handheld weights of 2 and 4 kg. A 3D full-resolution convolutional neural network (nnU-Net) was trained to automatically locate five landmarks (glenohumeral joint centre, humeral shaft, inferior and superior edges of the glenoid and most lateral point of the acromion) and a calibration sphere. RESULTS The nnU-Net was trained with ground-truth data from 6021 fluoroscopic images of 40 shoulders and tested with 1925 fluoroscopic images of 10 shoulders. The automatic landmark detection algorithm achieved an accuracy above inter-rater variability and slightly below intra-rater variability. All landmarks and the calibration sphere were located within 1.5 mm, except the humeral landmark within 9.6 mm, but differences in abduction angles were within 1°. CONCLUSION The proposed algorithm detects the desired landmarks on fluoroscopic images with sufficient accuracy and can therefore be applied to automatically assess shoulder motion, scapular rotation or glenohumeral translation in the scapular plane. CLINICAL RELEVANCE STATEMENT This nnU-net algorithm facilitates efficient and objective identification and tracking of anatomical landmarks on fluoroscopic images necessary for measuring clinically relevant anatomical configuration (e.g. critical shoulder angle) and enables investigation of dynamic glenohumeral joint stability in pathological shoulders. KEY POINTS • Anatomical configuration and glenohumeral joint stability are often a concern after rotator cuff tears. • Artificial intelligence applied to fluoroscopic images helps to identify and track anatomical landmarks during dynamic movements. • The developed automatic landmark detection algorithm optimised the labelling procedures and is suitable for clinical application

    Ex-vivo experimental strategies for assessing unconstrained shoulder biomechanics : a scoping review protocol

    Get PDF
    Background: Shoulder biomechanics cannot be measured directly in living persons. While different glenohumeral joint simulators have been developed to investigate the role of the glenohumeral muscles in shoulder biomechanics, a standard for these simulators has not been defined. With this scoping review we want to describe available ex-vivo experimental strategies for assessing unconstrained shoulder biomechanics. Objective: The scoping review aims at identifying methodological and/or experimental studies describing or involving ex-vivo simulators that assess unconstrained shoulder biomechanics and synthesizing their strengths and limitations. Inclusion criteria: All unconstrained glenohumeral joint simulators published in connection with ex-vivo or mechanical simulation experiments will be included. Studies on glenohumeral simulators with active components to mimic the muscles will be included. We will exclude studies where the experiment is static or the motion is induced through an external guide, e.g., a robotic device. Methods: We will perform database searching in PubMed, Embase via Elsevier and Web of Science. Two reviewers will independently assess full texts of selected abstracts. Direct backward and forward citation tracking on included articles will be conducted. We will narratively synthesize the results and derive recommendations for designing ex-vivo simulators for assessing unconstrained shoulder biomechanics

    Exploring the vaccine conversation on TikTok in Italy: beyond classic vaccine stances

    Get PDF
    TikTok, a social media platform for creating and sharing short videos, has seen a surge in popularity during the COVID-19 pandemic. To analyse the Italian vaccine conversation on TikTok, we downloaded a sample of videos with a high play count (Top Videos), identified through an unofficial Application Programming Interface (consistent with TikTok’s Terms of Service), and collected public videos from vaccine sceptic users through snowball sampling (Vaccine Sceptics’ videos). The videos were analysed using qualitative and quantitative methods, in terms of vaccine stance, tone of voice, topic, conformity with TikTok style, and other characteristics. The final datasets consisted of 754 Top Videos (by 510 single users) plus 180 Vaccine Sceptics’ videos (by 29 single users), posted between January 2020 and March 2021. In 40.5% of the Top Videos the stance was promotional, 33.9% were indefinite-ironic, 11.3% were neutral, 9.7% were discouraging, and 3.1% were ambiguous (i.e. expressing an ambivalent stance towards vaccines); 43% of promotional videos were from healthcare professionals. More than 95% of the Vaccine Sceptic videos were discouraging. Multiple correspondence analysis showed that, compared to other stances, promotional videos were more frequently created by healthcare professionals and by females, and their most frequent topic was herd immunity. Discouraging videos were associated with a polemical tone of voice and their topics were conspiracy and freedom of choice. Our analysis shows that Italian vaccine-sceptic users on TikTok are limited in number and vocality, and the large proportion of videos with an indefinite-ironic stance might imply that the incidence of affective polarisation could be lower on TikTok, compared to other social media, in the Italian context. Safety is the most frequent concern of users, and we recorded an interesting presence of healthcare professionals among the creators. TikTok should be considered as a medium for vaccine communication and for vaccine promotion campaigns

    Reliability of the fluoroscopic assessment of load-induced glenohumeral translation during a 30° shoulder abduction test

    Get PDF
    Rotator cuff tears are often linked to superior translational instability, but a thorough understanding of glenohumeral motion is lacking. This study aimed to assess the reliability of fluoroscopically measured glenohumeral translation during a shoulder abduction test. Ten patients with rotator cuff tears participated in this study. Fluoroscopic images were acquired during 30° abduction and adduction in the scapular plane with and without handheld weights of 2 kg and 4 kg. Images were labelled by two raters, and inferior-superior glenohumeral translation was calculated. During abduction, glenohumeral translation (mean (standard deviation)) ranged from 3.3 (2.2) mm for 0 kg to 4.1 (1.8) mm for 4 kg, and from 2.3 (1.5) mm for 0 kg to 3.8 (2.2) mm for 4 kg for the asymptomatic and symptomatic sides, respectively. For the translation range, moderate to good interrater (intra-class correlation coefficient ICC [95% confidence interval (CI)]; abduction: 0.803 [0.691; 0.877]; adduction: 0.705 [0.551; 0.813]) and intrarater reliabilities (ICC [95% CI]; abduction: 0.817 [0.712; 0.887]; adduction: 0.688 [0.529; 0.801]) were found. Differences in the translation range between the repeated measurements were not statistically significant (mean difference, interrater: abduction, -0.1 mm, p = 0.686; adduction, -0.1 mm, p = 0.466; intrarater: abduction 0.0 mm, p = 0.888; adduction, 0.2 mm, p = 0.275). This method is suitable for measuring inferior-superior glenohumeral translation in the scapular plane

    Load-induced glenohumeral translation after rotator cuff tears : protocol for an in vivo study

    Get PDF
    Background: Rotator cuff tears are a common shoulder injury, but they sometimes remain undiagnosed, as symptoms can be limited. Altered shoulder biomechanics can lead to secondary damage and degeneration. In biomechanical analyses, the shoulder (ie, the glenohumeral joint) is normally idealized as a ball-and-socket joint, even though a translation is often observed clinically. To date, no conclusive changes in glenohumeral translation have been reported in patients with rotator cuff tears, and it is unknown how an additional handheld weight that is comparable to those used during daily activities will affect glenohumeral translations in patients with rotator cuff tears. Objective: This study aims to assess the load-induced glenohumeral translation (liTr) in patients with rotator cuff tears and its association with the load-induced changes in muscle activation (liMA). Methods: Patients and asymptomatic controls will be recruited. Participants will fill out health questionnaires and perform 30° arm abduction and adduction trials, during which they will hold different handheld weights of a maximum of 4 kg while motion capture and electromyographic data are collected. In addition, fluoroscopic images of the shoulders will be taken for the same movements. Isometric shoulder muscle strength for abduction and rotation will be assessed with a dynamometer. Finally, shoulder magnetic resonance images will be acquired to assess muscle status and injury presence. The dose-response relationship between additional weight, liTr, and liMA will be evaluated. Results: Recruitment and data collection began in May 2021, and they will last until the recruitment target is achieved. Data collection is expected to be completed by the end of 2022. As of November 2022, data processing and analysis are in progress, and the first results are expected to be submitted for publication in 2023. Conclusions: This study will aid our understanding of biological variations in liTr, the influence of disease pathology on liTr, the potential compensation of rotator cuff tears by muscle activation and size, and the association between liTr and patient outcomes. The outcomes will be relevant for diagnosis, treatment, and rehabilitation planning in patients with rotator cuff tears

    Health professionals who have worked in COVID-19 immunization centers suffer the effects of violence

    Get PDF
    BackgroundThe phenomenon violence against health professionals has received increasing attention in recent years because of its frequency and significant impact on victims’ mental health and disruption of health services. Despite this attention, little is known about the incidence of workplace violence in the highly politicized immunization services. Therefore, we decided to examine the prevalence of workplace violence in the COVID-19 immunization campaign, the risk and protective factors, and the impact on victims’ mental health.MethodsBetween March and April 2022, we conducted an anonymous online survey among health professionals working in COVID-19 vaccination centers in the Friuli-Venezia Giulia Region (Italy). We used the Questionnaire for Workplace Violence in Healthcare Settings and the Impact of Event Scale–Revised.ResultsOf the 200 participants, 93 (46.5%) reported being victims of an act of violence during the vaccination campaign, 60 of them verbally and 7 physically. In 35.5% of cases, the IES score indicated a possible post-traumatic stress reaction in the victim. Opinions on measures to prevent violence and support workers in the workplace differed according to the sex of the health professional, with women emphasizing the need for self-defense training and improvement of security arrangements (p < 0.001).ConclusionOne-third of health professionals involved in the COVID-19 immunization campaign reported that their mental health was affected by workplace violence. Public health professionals dealing with politicized and debated issues such as immunization should receive more attention, as should the implementation of a more structured and multidisciplinary approach to the problem within healthcare organizations

    Higher Frequencies of Lymphocytes Expressing the Natural Killer Group 2D Receptor in Patients With Behçet Disease

    Get PDF
    Behçet disease (BD) is an inflammatory systemic disease with a fluctuating course, which can affect the skin, eyes, central nervous system, musculoskeletal, gastrointestinal, and vascular systems. No laboratory tests are currently available for the diagnosis of BD and monitoring disease activity. Moreover there is a lack of knowledge on BD pathogenesis. This study focused on circulating Natural Killer (NK), NKT and T cells evaluated as CD3neg CD56pos, CD3pos CD56pos, and CD3pos CD56neg. Peripheral blood mononuclear cells (PBMCs) were collected from 38 BD patients and 20 healthy controls (HC). The frequencies of NK, NKT, and T cells expressing CD16, CD69, NKG2D, Nkp30, Nkp46, and NKG2A were assessed by flow cytometry. Cytotoxic potential of NK cells was evaluated by flow cytometry as the percentage of cells expressing the degranulation marker CD107a after incubation with K562 cells. The levels of 27 cytokines were determined in plasma with a multiplex bead-based assay. Higher percentages of NK, NKT, and T cells expressing NKG2D were detected in PBMCs of BD patients than HC. ROC curve analysis showed that the evaluation of NKG2Dpos NK, NKT, and T cell percentages discriminated between BD patients and HC. Moreover, there was a positive correlation between the BD Current Activity Form (BDCAF) scores and the frequencies of NKG2Dpos NK and NKT cells. A higher frequency of NK cells expressing CD107a was induced in PBMCs from BD patients than HC after incubation with K562 cells. Concentrations of IL-5, IL-6, IL-10, IL-13, IP-10, and MIP-1β were higher in plasma of BD patients than HC. Monitoring the frequencies of NKG2Dpos lymphocytes could help the clinicians in BD patients management. In addition, the increased expression of NKG2D in BD patients is likely involved in disease pathogenesis

    Neutralizing antibodies to Omicron after the fourth SARS-CoV-2 mRNA vaccine dose in immunocompromised patients highlight the need of additional boosters

    Get PDF
    IntroductionImmunocompromised patients have been shown to have an impaired immune response to COVID-19 vaccines.MethodsHere we compared the B-cell, T-cell and neutralizing antibody response to WT and Omicron BA.2 SARS-CoV-2 virus after the fourth dose of mRNA COVID-19 vaccines in patients with hematological malignancies (HM, n=71), solid tumors (ST, n=39) and immune-rheumatological (IR, n=25) diseases. The humoral and T-cell responses to SARS-CoV-2 vaccination were analyzed by quantifying the anti-RBD antibodies, their neutralization activity and the IFN-Îł released after spike specific stimulation.ResultsWe show that the T-cell response is similarly boosted by the fourth dose across the different subgroups, while the antibody response is improved only in patients not receiving B-cell targeted therapies, independent on the pathology. However, 9% of patients with anti-RBD antibodies did not have neutralizing antibodies to either virus variants, while an additional 5.7% did not have neutralizing antibodies to Omicron BA.2, making these patients particularly vulnerable to SARS-CoV-2 infection. The increment of neutralizing antibodies was very similar towards Omicron BA.2 and WT virus after the third or fourth dose of vaccine, suggesting that there is no preferential skewing towards either virus variant with the booster dose. The only limited step is the amount of antibodies that are elicited after vaccination, thus increasing the probability of developing neutralizing antibodies to both variants of virus.DiscussionThese data support the recommendation of additional booster doses in frail patients to enhance the development of a B-cell response directed against Omicron and/or to enhance the T-cell response in patients treated with anti-CD20

    Reliability of the Fluoroscopic Assessment of Load-Induced Glenohumeral Translation during a 30° Shoulder Abduction Test

    No full text
    Rotator cuff tears are often linked to superior translational instability, but a thorough understanding of glenohumeral motion is lacking. This study aimed to assess the reliability of fluoroscopically measured glenohumeral translation during a shoulder abduction test. Ten patients with rotator cuff tears participated in this study. Fluoroscopic images were acquired during 30° abduction and adduction in the scapular plane with and without handheld weights of 2 kg and 4 kg. Images were labelled by two raters, and inferior–superior glenohumeral translation was calculated. During abduction, glenohumeral translation (mean (standard deviation)) ranged from 3.3 (2.2) mm for 0 kg to 4.1 (1.8) mm for 4 kg, and from 2.3 (1.5) mm for 0 kg to 3.8 (2.2) mm for 4 kg for the asymptomatic and symptomatic sides, respectively. For the translation range, moderate to good interrater (intra-class correlation coefficient ICC [95% confidence interval (CI)]; abduction: 0.803 [0.691; 0.877]; adduction: 0.705 [0.551; 0.813]) and intrarater reliabilities (ICC [95% CI]; abduction: 0.817 [0.712; 0.887]; adduction: 0.688 [0.529; 0.801]) were found. Differences in the translation range between the repeated measurements were not statistically significant (mean difference, interrater: abduction, −0.1 mm, p = 0.686; adduction, −0.1 mm, p = 0.466; intrarater: abduction 0.0 mm, p = 0.888; adduction, 0.2 mm, p = 0.275). This method is suitable for measuring inferior–superior glenohumeral translation in the scapular plane
    corecore